NextSDS Logo
Safety Data Sheet EN

Castrol Hyspin AWH-M 100

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Castrol Hyspin AWH-M 100
Product Code
456599

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Hydraulic fluid For specific application advice see appropriate Technical Data Sheet or consult your Castrol representative.

Manufacturers & Suppliers

C

Castrol (UK) Ltd.

Witan Gate House, 500-600 Witan Gate, Central Milton Keynes, MK9 1ES, United Kingdom

Emergency Contacts

Emergency Contact

+44 (0) 1908 853000

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Highly refined mineral oil (IP 346 DMSO extract < 3%). Proprietary performance additives.

Chemical Name CAS Number Concentration Hazardous
Highly refined mineral oil --- --- No
Proprietary performance additives --- --- No

Notes

This product does not contain any hazardous ingredients at or above regulated thresholds.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. Get medical attention if symptoms appear.

Skin contact

In case of contact, immediately flush skin with plenty of water. Remove contaminated clothing and shoes. Wash clothing before reuse. Clean shoes thoroughly before reuse. Get medical attention if irritation develops.

Eye contact

In case of contact, immediately flush eyes with a copious amount of water for at least 15 minutes. Get medical attention if irritation occurs.

Ingestion

Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. If large quantities of this material are swallowed, call a physician immediately.

Immediate Medical Attention

If large quantities of this material are swallowed, call a physician immediately. Injections through the skin resulting from contact with the product at high pressure constitute a major medical emergency.

Medical Treatment

Treatment should in general be symptomatic and directed to relieving any effects. Surgical exploration should be undertaken without delay. Thorough and extensive debridement of the wound and underlying tissue is necessary to minimise tissue loss and prevent or limit permanent damage.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use water fog, foam, dry chemical or CO2 extinguisher or spray.

Unsuitable media

Do not use water jet.

Specific hazards

None identified.

Instructions

None identified.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Immediately contact emergency personnel. Keep unnecessary personnel away. Use suitable protective equipment (Section 8). Follow all fire fighting procedures (Section 5). If emergency personnel are unavailable, contain spilled material.

Small spill

For small spills add absorbent (soil may be used in the absence of other suitable materials) scoop up material and place in a sealed, liquid-proof container for disposal.

Large spill

For large spills dike spilled material or otherwise contain material to ensure runoff does not reach a waterway. Place spilled material in an appropriate container for disposal.

Environmental

Minimize contact of spilled material with soils to prevent runoff to surface waterways.

Cleanup methods

scoop up material and place in a sealed, liquid-proof container for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash thoroughly after handling.

Storage

Keep container tightly closed. Keep container in a cool, well-ventilated area.

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapours below their respective occupational exposure limits.

Hands

Wear gloves that cannot be penetrated by chemicals or oil.

Eyes

Safety glasses with side shields.

Respiratory

Use with adequate ventilation.

Skin/Body

Avoid contact with skin. Wear clothing and footwear that cannot be penetrated by chemicals or oil.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Molecular Weight
---
Crystallisation Point
---
Softening Point
---
Odor
Mild
Physical State Data
liquid
Dynamic Viscosity
---
Ph
---
Odor Threshold
Not available.
Relative Density
---
Explosive Limits
---
Kinematic Viscosity
100 mm²/s (100 cSt) at 40°C
Colour
Amber.
Solubility In Water
insoluble in water.
Metal Corrosion
---
Voc Content
---
Vapor Density
---
Boiling Point
---
Appearance
---
Properties Status
---
State Under Standard Conditions
---
Solubility In Fat
---
Partition Coefficient
---
Lower Explosive Limit
---
Flammability
---
Upper Explosive Limit
---
Flash Point
>200 °C (OPEN CUP)
Cloud Point
---
Bulk Density
---
Density
885 kg/m³ (0.9 g/cm³) at 15°C
Physical State
Liquid.
Decomposition Temperature
---
Auto Ignition Temperature
---
Solubility
insoluble in water.
Form
---
Melting Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Colour Intensity
---
Solidification Point
---
Vapor Pressure
---
Freezing Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

Will not occur.

Incompatible

Reactive with oxidizing agents.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Where possible, arrange for product to be recycled. Dispose of via an authorised person/ licensed waste disposal contractor in accordance with local regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This product is not classified according to the EU regulations.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Castrol Hyspin AWH-M 100?

The signal word is no signal word.

What is the physical form of Castrol Hyspin AWH-M 100?

Castrol Hyspin AWH-M 100 is a liquid. with amber. color. It has mild odor.

What is the solubility of Castrol Hyspin AWH-M 100?

insoluble in water.

What is Castrol Hyspin AWH-M 100 used for?

Hydraulic fluid For specific application advice see appropriate Technical Data Sheet or consult your Castrol representative.