Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ECO Floor 11
- Product Code
- 4003100 284176 293304
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- /
Identified Uses
Floor cleaner for professional use (AISE_SUMI_PW_4_1 // AISE_SUMI_PW_8a_2_G // AISE_SUMI_PW_10_1 // AISE_SUMI_PW_19_1)
Uses advised against
/
Manufacturers & Suppliers
Greenspeed
national supplier
P.O.Box 1250 2280 CG Rijswijk (ZH), NL
+31703458737
http://www.greenspeed.eu/
Emergency Contacts
Emergency Contact
+32 70 245 245
Nationaal Vergiftigingen Informatie Centrum (NVIC)
+31 88 755 8000
Emergency Contact
+33 (0)1 45 42 59 59
Emergency Contact
(+352) 8002-5500
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| alcohols, C10-16, ethoxylated, propoxylated | 69227-22-1 | 8.8% | Yes |
| Sodium carbonate EC: 207-838-8 | 497-19-8 | 1.8% | Yes |
| 3-Butoxypropane-2-ol EC: 225-878-4 | 5131-66-8 | 1.5% | Yes |
Notes
For the full text of the H phrases mentioned in this section, see section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of serious or continuous discomforts: remove to fresh air and seek medical attention.
Rinse with water.
Rinse first with plenty of water, if necessary seek medical attention.
Symptoms: Caustic, redness, blurred vision, pain
Rinse first with plenty of water, if necessary seek medical attention.
Symptoms: Diarrhoea, headache, abdominal cramps, sleepiness, vomiting
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, foam, powder, sprayed water
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not walk into or touch spilled substances and avoid inhalation of fumes, smoke, dusts and vapours by staying up wind. Remove any contaminated clothing and used contaminated protective equipment and dispose of it safely.
Do not allow to flow into sewers or open water.
remove by using absorbent material
Materials: absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle with care to avoid spillage.
Keep in a sealed container in a closed, frost-free, ventilated room.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Adequate ventilation should be provided so that exposure limits are not exceeded. For further information, check section 7.
Handling with nitril-gloves (EN 374). Breakthrough time: >480' Material thickness: 0,35 mm. Thoroughly check gloves before use. Take of the gloves properly without touching the outside with your bare hands. The manufacturer of the protective gloves has to be consulted about the suitability for a specific work station. Wash and dry your hands.
Keep an eye-rinse bottle within reach. Tight-fitting safety goggles. Wear a face shield and protective suit in case of exceptional processing problems.
Use with sufficient exhaust ventilation. If necessary, use an air-purifying face mask in case of respiratory hazards. Use the ABEK type as protection against these troublesome levels.
Wear impermeable clothing. The type of protective equipment depends on the concentration and amount of hazardous substances at the work station in question.
Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions. For further information, check sections 6 and 13.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Protect from sunlight and do not expose to temperatures exceeding + 50°C.
Under recommended usage conditions, hazardous decomposition products are not expected.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ECO Floor 11?
The signal word is danger.
What is the physical form of ECO Floor 11?
ECO Floor 11 is a liquid appearing as liquid with green color. It has characteristic odor.
What is ECO Floor 11 used for?
Floor cleaner for professional use (AISE_SUMI_PW_4_1 // AISE_SUMI_PW_8a_2_G // AISE_SUMI_PW_10_1 // AISE_SUMI_PW_19_1)
What are the hazard statements for ECO Floor 11?
This substance has 1 hazard statement:
- H318: Causes serious eye damage.
What is the melting point of ECO Floor 11?
The melting point is 0 °C and the boiling point is 100 °C – 199 °C.