Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ECO Floor 11
Product Code
4003100 284176 293304

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Floor cleaner for professional use (AISE_SUMI_PW_4_1 // AISE_SUMI_PW_8a_2_G // AISE_SUMI_PW_10_1 // AISE_SUMI_PW_19_1)

Manufacturers & Suppliers

Greenspeed logo

Greenspeed

national supplier

P.O.Box 1250, 2280 CG Rijswijk (ZH), NL

+31703458737

http://www.greenspeed.eu/

Emergency Contacts

Emergency Contact

+32 70 245 245

Nationaal Vergiftigingen Informatie Centrum (NVIC)

+31 88 755 8000

Emergency Contact

+33 (0)1 45 42 59 59

Emergency Contact

(+352) 8002-5500

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Eye Dam. Cat. 1 H318

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H318 Causes serious eye damage.

Precautionary Statements

P280 Wear protective gloves, protective clothing, eye protection, face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call a POISON CENTER or doctor.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
alcohols, C10-16, ethoxylated, propoxylated 69227-22-1 8.8% Yes
Sodium carbonate EC: 207-838-8 497-19-8 1.8% Yes
3-Butoxypropane-2-ol EC: 225-878-4 5131-66-8 1.5% Yes

Notes

For the full text of the H phrases mentioned in this section, see section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of serious or continuous discomforts: remove to fresh air and seek medical attention.

Skin contact

Rinse with water.

Eye contact

Rinse first with plenty of water, if necessary seek medical attention.

Symptoms: Caustic, redness, blurred vision, pain

Ingestion

Rinse first with plenty of water, if necessary seek medical attention.

Symptoms: Diarrhoea, headache, abdominal cramps, sleepiness, vomiting

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, foam, powder, sprayed water

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not walk into or touch spilled substances and avoid inhalation of fumes, smoke, dusts and vapours by staying up wind. Remove any contaminated clothing and used contaminated protective equipment and dispose of it safely.

Environmental

Do not allow to flow into sewers or open water.

Cleanup methods

If possible, remove by using absorbent material.

Materials: absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle with care to avoid spillage.

Storage

Keep in a sealed container in a closed, frost-free, ventilated room.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Adequate ventilation should be provided so that exposure limits are not exceeded. For further information, check section 7.

Hands

Handling with nitril-gloves (EN 374). Breakthrough time: >480' Material thickness: 0,35 mm. Thoroughly check gloves before use. Take of the gloves properly without touching the outside with your bare hands. The manufacturer of the protective gloves has to be consulted about the suitability for a specific work station. Wash and dry your hands.

Eyes

Keep an eye-rinse bottle within reach. Tight-fitting safety goggles. Wear a face shield and protective suit in case of exceptional processing problems.

Respiratory

Use with sufficient exhaust ventilation. If necessary, use an air-purifying face mask in case of respiratory hazards. Use the ABEK type as protection against these troublesome levels.

Skin/Body

Wear impermeable clothing. The type of protective equipment depends on the concentration and amount of hazardous substances at the work station in question.

Environmental

Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions. For further information, check sections 6 and 13.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Density
---
Softening Point
---
Relative Evaporation Rate
---
Physical State Data
liquid
Physical State
Liquid
State Under Standard Conditions
---
Upper Explosive Limit
8.700 %
Freezing Point
---
Evaporation Rate
2.000
Kinematic Viscosity
1 mm²/s
Colour Intensity
---
Solubility
---
Solidification Point
---
Explosive Limits
---
Solubility In Fat
---
Dynamic Viscosity
1 mPa.s
Metal Corrosion
---
Form
---
Crystallisation Point
---
Appearance
Liquid
Decomposition Temperature
/
Properties Status
---
Auto Ignition Temperature
207 °C
Cloud Point
---
Bulk Density
---
Flammability
Not applicable
Ph
11.4
Molecular Weight
---
Voc Content
4.00 %
Lower Explosive Limit
1.100 %
Odor Threshold
---
Melting Point
0 °C
Relative Density
1.0030 kg/l
Vapor Pressure
2,332 Pa
Partition Coefficient
Not applicable
Colour
green
Vapor Density
Not applicable
Solubility In Water
Completely soluble
Odor
characteristic
Flash Point
/
Boiling Point
100 °C – 199 °C
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Extremely high or low temperatures.

Reactivity

Stable under normal conditions.

Avoid

Protect from sunlight and do not expose to temperatures exceeding + 50°C.

Decomposition

Under recommended usage conditions, hazardous decomposition products are not expected.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity:

Sodium carbonate | LC50 (Fish): 300 mg/L (96h) | EC50 (Daphnia): 200 - 227 mg/L (48h) 3-Butoxypropane-2-ol | LC50 (Fish): > 560 - 1000 mg/L (96h) | NOEC (Fish): 180 mg/L (96h) | NOEC (Daphnia): 560 mg/L (48h) | EC50 (Algae): > 1000 mg/L (96h) | NOEC (Algae): 560 mg/L (96h) | EC50 (soil microorganisms): > 1000 mg/L (3h)

12.2 Persistence and degradability:

The surfactants contained in this preparation comply with the biodegradability criteria as laid down in Regulation (EC) No.648/2004 on detergents.

12.3 Bioaccumulative potential:

No additional data available

12.4 Mobility in soil:

Water hazard class, WGK (AwSV): 1 Solubility in water: Completely soluble

12.5 Results of PBT and vPvB assessment:

No additional data available

12.6 Endocrine disrupting properties:

No additional data available

12.7 Other adverse effects:

No additional data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The product may be discharged in the indicated percentages of utilization, provided it is neutralised to pH 7.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable
Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

Composition by regulation (EC) 648/2004: Nonionic surfactants 5% - 15%, Perfumes

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ECO Floor 11?

The signal word is danger.

What is the physical form of ECO Floor 11?

ECO Floor 11 is a liquid appearing as liquid with green color. It has characteristic odor.

What is ECO Floor 11 used for?

Floor cleaner for professional use (AISE_SUMI_PW_4_1 // AISE_SUMI_PW_8a_2_G // AISE_SUMI_PW_10_1 // AISE_SUMI_PW_19_1)

What are the hazard statements for ECO Floor 11?

This substance has 1 hazard statement:

  • H318: Causes serious eye damage.

What is the melting point of ECO Floor 11?

The melting point is 0 °C and the boiling point is 100 °C – 199 °C.