NextSDS Logo
Safety Data Sheet EN

283412_Crystal Calc

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
283412_Crystal Calc

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Limescale remover

Manufacturers & Suppliers

Greenspeed logo

Greenspeed

P.O.Box 1250 2280 CG Rijswijk (ZH), NL

+31703458737

http://www.greenspeed.eu/

Emergency Contacts

Emergency Contact

+32 70 245 245

Nationaal Vergiftigingen Informatie Centrum (NVIC)

+31 88 755 8000

Emergency Contact

+33 (0)1 45 42 59 59

Emergency Contact

(+352) 8002-5500

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Corr. Cat. 1A H314
Eye Dam. Cat. 1 H318

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H314 Causes severe skin burns and eye damage.

Precautionary Statements

P280 Wear protective gloves, protective clothing, eye protection, face protection.
P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water or shower.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call a POISON CENTER or doctor.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Formic acid EC: 200-579-1 64-18-6 20% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Let sit upright, fresh air, rest and take to hospital.

Symptoms: Headache, dizziness, nausea, drowsiness, unconsciousness

Skin contact

Remove contaminated clothing, rinse skin with plenty of water and immediately transport to hospital.

Symptoms: Caustic, redness, pain, serious burns

Eye contact

Thoroughly rinse with water (contact lenses to be removed if this is easily done) then take to physician.

Symptoms: Caustic, redness, blurred vision, pain

Ingestion

Rinse mouth, do not induce vomiting, take to hospital immediately.

Symptoms: Caustic, lack of breath, vomiting, blisters on lips and tongue, burning pain in mouth and throat, gullet and stomach

Immediate Medical Attention

Immediate medical attention is required for skin contact (transport to hospital immediately), ingestion (take to hospital immediately), eye contact (take to physician), and inhalation (take to hospital). Seek medical advice as soon as possible should serious or continuous disturbances occur.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, foam, powder, sprayed water

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not walk into or touch spilled substances and avoid inhalation of fumes, smoke, dusts and vapours by staying up wind. Remove any contaminated clothing and used contaminated protective equipment and dispose of it safely.

Environmental

Do not allow to flow into sewers or open water.

Cleanup methods

If possible, remove by using absorbent material.

Materials: absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle with care to avoid spillage.

Storage

Keep in a sealed container in a closed, frost-free, ventilated room.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Adequate ventilation should be provided so that exposure limits are not exceeded. For further information, check section 7.

Hands

Handling with Viton-gloves (EN 374). Breakthrough time: >480° Material thickness: 0,7 mm. Thoroughly check gloves before use. Take of the gloves properly without touching the outside with your bare hands. The manufacturer of the protective gloves has to be consulted about the suitability for a specific work station. Wash and dry your hands.

Eyes

Keep an eye-rinse bottle within reach. Tight-fitting safety goggles. Wear a face shield and protective suit in case of exceptional processing problems.

Respiratory

Use with sufficient exhaust ventilation. If necessary, use an air-purifying face mask in case of respiratory hazards. Use the ABEK type as protection against these troublesome levels.

Skin/Body

Wear impermeable clothing. The type of protective equipment depends on the concentration and amount of hazardous substances at the work station in question.

Environmental

Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions. For further information, check sections 6 and 13.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Appearance
Liquid
Flash Point
---
Freezing Point
---
Physical State Data
liquid
Colour
yellow
Evaporation Rate
0.300
Vapor Density
Not applicable
Solubility In Fat
---
Decomposition Temperature
---
Relative Evaporation Rate
---
State Under Standard Conditions
---
Crystallisation Point
---
Explosive Limits
---
Cloud Point
---
Flammability
Not applicable
Odor Threshold
---
Upper Explosive Limit
---
Dynamic Viscosity
1 mPa.s
Properties Status
---
Lower Explosive Limit
---
Melting Point
0 °C
Molecular Weight
---
Density
---
Solubility In Water
Completely soluble
Physical State
Liquid
Vapor Pressure
2,332 Pa
Colour Intensity
---
Kinematic Viscosity
1 mm²/s
Relative Density
1.0390 kg/l
Softening Point
---
Bulk Density
---
Boiling Point
100 °C – 100 °C
Partition Coefficient
Not applicable
Odor
characteristic
Form
---
Solidification Point
---
Metal Corrosion
---
Solubility
---
Voc Content
16.98 %
Auto Ignition Temperature
---
Ph
2.0
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Extremely high or low temperatures.

Reactivity

Stable under normal conditions.

Avoid

Protect from sunlight and do not expose to temperatures exceeding + 50°C.

Incompatible

Oxidants, alkalines

Decomposition

Under recommended usage conditions, hazardous decomposition products are not expected.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3412
Shipping Name
Formic acid
Transport Class
8
Packing Group
II
IMDG

Hazard characteristics: Risk of burns. Risk to the aquatic environment and the sewerage system.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 283412_Crystal Calc?

The signal word is danger.

What is the physical form of 283412_Crystal Calc?

283412_Crystal Calc is a liquid appearing as liquid with yellow color. It has characteristic odor.

What is 283412_Crystal Calc used for?

Limescale remover

What are the hazard statements for 283412_Crystal Calc?

This substance has 1 hazard statement:

  • H314: Causes severe skin burns and eye damage.

What is the melting point of 283412_Crystal Calc?

The melting point is 0 °C and the boiling point is 100 °C – 100 °C.

Compliance Scanner

Scan your compliance