Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RADIACID 0971
- Product Form
- Substance (UVCB)
- Chemical Name
- Fatty acids, C18-unsatd., dimers
Regulatory Identifiers
- CAS Number
- 61788-89-4 Check regulations →
- EC Number
- 500-148-0 Check regulations →
- REACH No.
- 01-2119493908-18
Identified Uses
General overview of industrial uses of dimerized fatty acids consortium related substances; Supplementary overview of industrial uses of non classified commercial fatty acids; General overview of professional uses of dimerized fatty acids related substances; General overview of consumer uses of dimerized fatty acids related substances
Uses advised against
No additional information available
Manufacturers & Suppliers
OLEON N.V.
manufacturer
Assenedestraat 2, 9940 Ertvelde - Belgium
+32 9 341 10 11
http://www.oleon.com
Emergency Contacts
SGS ERS; Oleon contract nr 76858
+32 3 575 55 55
24/7
SGS ERS; Oleon contract nr 76858
+1 888 765 6554
24/7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Fatty acids, C18-unsatd., dimers EC: 500-148-0 | 61788-89-4 | 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.
Symptoms: ON HEATING: Irritation of the respiratory tract.
Wash immediately with lots of water. Soap may be used. Take victim to a doctor if irritation persists.
Rinse immediately with plenty of water. Take victim to an ophthalmologist if irritation persists.
Rinse mouth with water. Call Poison Information Centre (www.who.int/ipcs/poisons/centre/directory/en). Consult a doctor/medical service if you feel unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
DIRECT FIRE HAZARD: Combustible. INDIRECT FIRE HAZARD: Heating increases the fire hazard. Temperature above flashpoint: higher fire/explosion hazard. DIRECT EXPLOSION HAZARD: Fine dust is explosive with air. INDIRECT EXPLOSION HAZARD: Dust cloud can be ignited by a spark.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mark the danger area. Exposure to heat: have neighbourhood close doors and windows. Exposure to fire/heat: consider evacuation. Wash contaminated clothes.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep container in a well-ventilated place. Store at ambient temperature. Keep out of direct sunlight. Meet the legal requirements.
Keep away from ignition sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Gloves. GIVE GOOD RESISTANCE: nitrile rubber
Safety glasses
Protective clothing. GIVE GOOD RESISTANCE: nitrile rubber
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
On burning: release of (carbon monoxide - carbon dioxide).
No additional information available
No supplementary information available.
No supplementary information available.
No supplementary information available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Prevent dispersion by covering with dry absorbent, Scoop solid spill into closing containers, Scoop absorbed substance into closing containers, Clean contaminated surfaces with an excess of water and soap solution, Wash clothing and equipment after handling
Remove to an authorized waste treatment plant.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not applicable
- Shipping Name
- Not applicable
- Transport Class
- Not applicable
- Packing Group
- Not applicable
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RADIACID 0971?
The signal word is no signal word.
What is the physical form of RADIACID 0971?
RADIACID 0971 is a liquid appearing as clear. viscous. with light yellow to dark yellow. color. It has characteristic odour. mild odour. odor.
What is the solubility of RADIACID 0971?
Water: < 0,005 g/100ml (25°C). Poorly soluble in water. Soluble in oils/fats. soluble in most organic solvents.
What is RADIACID 0971 used for?
General overview of industrial uses of dimerized fatty acids consortium related substances; Supplementary overview of industrial uses of non classified commercial fatty acids; General overview of professional uses of dimerized fatty acids related substances; General overview of consumer uses of dimerized fatty acids related substances
What is the melting point of RADIACID 0971?
The melting point is No supplementary information available and the boiling point is > 250 °C.