Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RADIA 7090
- Product Form
- Substance (UVCB)
- Chemical Name
- Fatty acids, C18-unsatd., dimers, methyl esters
Regulatory Identifiers
- CAS Number
- 68604-84-2 Check regulations →
- EC Number
- 500-225-9 Check regulations →
- REACH No.
- 01-2119963371-38
Identified Uses
Main use category : Industrial use Uses at industrial sites of transported intermediates (Life cycle stage: Industrial, Use descriptors: SU8, SU9, PC19, PROC2, PROC3, PROC8b, PROC9, ERC6a) Manufacturing of transported intermediates (Use descriptors: PROC2, PROC3, PROC8b, PROC9, ERC1) Formulation of transported intermediates (Use descriptors: PC19, PROC2, PROC3, PROC8b, PROC9, ERC2) Full text of use descriptors: see section 16
Manufacturers & Suppliers
OLEON N.V.
Assenedestraat 2 BE 9940 Ertvelde Belgium
+32 9 341 10 11
www.oleon.com
Emergency Contacts
SGS ERS
+32 3 575 55 55
24/7
SGS ERS
+1 888 765 6554
24/7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Fatty acids, C18-unsatd., dimers, methyl esters EC: 500-225-9 | 68604-84-2 | 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air. Respiratory problems: consult a doctor/medical service.
Wash off immediately with soap and plenty of water. If irritation persists, consult a doctor.
Rinse immediately with plenty of water. Consult an ophthalmologist if irritation persists.
Rinse mouth out with water. Get medical advice/attention if you feel unwell. Call a poison center (www.who.int/ipcs/poisons/centre/directory/en).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
AFFF foam. BC-powder. Carbon dioxide. Dry sand. Dry chemical powder. Use the extinguishing media recommended for the burning materials and fire situation.
Do not use water jet.
DIRECT FIRE HAZARD: Combustible. INDIRECT FIRE HAZARD: Heating may cause a fire or explosion. Temperature above flashpoint: higher fire/explosion hazard. Explosion hazard : No supplementary information available.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mark the danger area. Exposure to fire/heat: have neighbourhood close doors and windows. Exposure to fire/heat: consider evacuation. Wash contaminated clothing before reuse.
Prevent soil and water pollution.
Clean contaminated surfaces with a soap solution. Flush/dilute with water. Take up liquid spill into absorbent material
Materials: soap solution, water, absorbent material, e.g.: sand, earth, vermiculite or powdered limestone.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handling temperature : ≥ 10 °C above melting point
Keep container in a well-ventilated place. Store at ambient temperature. Keep out of direct sunlight. Meet the legal requirements.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Gloves.
Safety glasses.
Protective clothing. Materials for protective clothing: Good resistance: Nitrile rubber
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
On burning: release of carbon monoxide/carbon dioxide.
No additional information available
No supplementary information available.
No supplementary information available.
No supplementary information available.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Shipping Name
- Not applicable
- Transport Class
- Not applicable
- Packing Group
- Not applicable
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RADIA 7090?
The signal word is no signal word.
What is the physical form of RADIA 7090?
RADIA 7090 is a liquid appearing as liquid. with yellow-amber. color. It has characteristic. mild odor. odor.
What is the solubility of RADIA 7090?
Not available
What is RADIA 7090 used for?
Main use category : Industrial use Uses at industrial sites of transported intermediates (Life cycle stage: Industrial, Use descriptors: SU8, SU9, PC19, PROC2, PROC3, PROC8b, PROC9, ERC6a) Manufacturing of transported intermediates (Use descriptors: PROC2, PROC3, PROC8b, PROC9, ERC1) Formulation of transported intermediates (Use descriptors: PC19, PROC2, PROC3, PROC8b, PROC9, ERC2) Full text of use descriptors: see section 16
What is the melting point of RADIA 7090?
The melting point is < 10 °C and the boiling point is > 150 °C.