01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RADIA 7956
Product Form
Substance (UVCB)
Chemical Name
Fatty acids, C16-18 (even numbered) and C18-unsatd., Me esters
Synonyms
Ester méthylique d'huile de colza

Regulatory Identifiers

CAS Number
67762-38-3 Check regulations →
EC Number
267-015-4 Check regulations →
REACH No.
01-2119471664-32

Identified Uses

Industrial use, Professional, Consumer, Formulation, Manufacturing

Uses advised against

No additional information available

Manufacturers & Suppliers

OLEON N.V. logo

OLEON N.V.

manufacturer

Assenedestraat 2, 9940 Ertvelde - Belgium

+32 9 341 10 11

http://www.oleon.com

Emergency Contacts

SGS ERS

+32 3 575 55 55

SGS ERS

+1 888 765 6554

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb
Chemical Name CAS Number Concentration Hazardous
Fatty acids, C16-18 and C18-unsatd., Me esters EC: 267-015-4 67762-38-3 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.

Skin contact

Wash immediately with lots of water. Soap may be used. Take victim to a doctor if irritation persists.

Eye contact

Rinse immediately with plenty of water. Take victim to an ophthalmologist if irritation persists.

Ingestion

Rinse mouth with water. Call Poison Information Centre (www.who.int/ipcs/poisons/centre/directory/en). Consult a doctor/medical service if you feel unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

AFFF foam. BC powder. Carbon dioxide. Dry sand. Dry chemical powder. Adapt extinguishing media to the environment.

Unsuitable media

Solid water jet ineffective as extinguishing medium.

Specific hazards

DIRECT FIRE HAZARD: Combustible. INDIRECT FIRE HAZARD: Heating increases the fire hazard. Temperature above flashpoint: higher fire/explosion hazard.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Mark the danger area. Exposure to heat: have neighbourhood close doors and windows. Exposure to fire/heat: consider evacuation. Wash contaminated clothes.

Environmental

Prevent soil and water pollution.

Cleanup methods

Clean contaminated surfaces with an excess of water and soap solution.

Materials: water and soap solution

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handling temperature: ≥ 10 °C above melting point

Storage

Keep container in a well-ventilated place. Store at ambient temperature. Keep out of direct sunlight. Meet the legal requirements.

Fire prevention

KEEP SUBSTANCE AWAY FROM: ignition sources.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Gloves. GIVE GOOD RESISTANCE: nitrile rubber

Eyes

Safety glasses

Skin/Body

Protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Form
---
Physical State Data
liquid
Lower Explosive Limit
No data available
Upper Explosive Limit
No data available
Relative Evaporation Rate
No data available
Kinematic Viscosity
4 - 5 mm²/s (40°C)
Melting Point
< 0 °C
Voc Content
< 0,1 % (1999/13/EC; 2004/42/EC; 2010/75/EU)
Explosive Limits
---
Flash Point
190 °C (open cup)
State Under Standard Conditions
---
Crystallisation Point
---
Vapor Density
---
Odor
Characteristic odour. Mild odour.
Properties Status
---
Auto Ignition Temperature
> 250 °C
Bulk Density
---
Relative Density
No data available
Solubility In Water
Poorly soluble in water.
Solubility In Fat
Soluble in oils/fats.
Boiling Point
> 240 °C
Vapor Pressure
No supplementary information available
Flammability
No data available
Cloud Point
---
Molecular Weight
---
Decomposition Temperature
No data available
Ph
5 - 8
Colour Intensity
---
Partition Coefficient
> 3
Metal Corrosion
---
Solidification Point
---
Odor Threshold
No data available
Solubility
No data available
Freezing Point
No data available
Colour
Yellow to amber.
Appearance
Liquid.
Evaporation Rate
---
Dynamic Viscosity
No data available
Softening Point
---
Physical State
Liquid
Density
ca. 0,88 g/cm³ (20°C)
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

On burning: release of (carbon monoxide - carbon dioxide).

Hazardous reactions

No additional information available

Avoid

No supplementary information available.

Incompatible

No supplementary information available.

Decomposition

No supplementary information available.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Prevent dispersion by covering with dry absorbent, Scoop solid spill into closing containers, Scoop absorbed substance into closing containers, Clean contaminated surfaces with an excess of water and soap solution, Wash clothing and equipment after handling

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable
Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The chemical safety assessment has been carried out, an exposure scenario is not applicable (substance is not classified).

Chemical Safety Assessment Performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is RADIA 7956 known by?

RADIA 7956 is also known as: Ester méthylique d'huile de colza

What is the hazard signal word for RADIA 7956?

The signal word is no signal word.

What is the physical form of RADIA 7956?

RADIA 7956 is a liquid appearing as liquid. with yellow to amber. color. It has characteristic odour. mild odour. odor.

What is the solubility of RADIA 7956?

No data available

What is RADIA 7956 used for?

Industrial use, Professional, Consumer, Formulation, Manufacturing

What is the melting point of RADIA 7956?

The melting point is < 0 °C and the boiling point is > 240 °C.