Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HiTEC® 11600 Performance Additive
- Product Form
- Liquid
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 1A7Y-EMK7-D87C-4SK6
Identified Uses
Formulation of additive packages, lubricants and greases - Industrial; General use of lubricants and greases in vehicles or machinery - Industrial; General use of lubricants and greases in vehicles or machinery - Professional
Manufacturers & Suppliers
Afton Chemical Limited
manufacturer
Euro-Tech Centre, London Road, Bracknell, RG12 2UW, England
+44 1344 304141
Afton Chemical S.R.L. (Woluwe)
manufacturer
Alma Court, Lenneke Marelaan, 8, B-1932, St-Stevens-Woluwe, Belgium
+32 2 715 2211
Afton Chemical S.R.L. (Feluy Plant)
manufacturer
Rue de Scoufflény, 50, B-7191 Ecaussinnes Lalaing, Belgium
+32 67 286211
Afton Chemical India PVT Ltd
manufacturer
Lotus Corporate Park, 7th Floor, A Wing, Ram Mandir Lane, Western Express Highway, Goregaon East, Mumbai 400063 India
+91 22 6728 0200
Emergency Contacts
Austria
+43 1 364 92 37
24 hours a day, 7 days a week
Belgium
+32 2 808 32 37
24 hours a day, 7 days a week
Bulgaria
+359 32 570 104
24 hours a day, 7 days a week
Croatia
+385 1 7776 920
24 hours a day, 7 days a week
Czech Republic
+420 228 880 039
24 hours a day, 7 days a week
Denmark
+45 69 91 85 73
24 hours a day, 7 days a week
Finland
+358 9 42725036
24 hours a day, 7 days a week
France
+33 9 75 18 14 07
24 hours a day, 7 days a week
Germany
0800 1817059
24 hours a day, 7 days a week
Greece
+30 21 1176 8478
24 hours a day, 7 days a week
Hungary
+36 1 808 8425
24 hours a day, 7 days a week
India
+91 8071 279 207
24 hours a day, 7 days a week
Ireland
+353 1 901 4670
24 hours a day, 7 days a week
Italy
+39 02 4555 7031
24 hours a day, 7 days a week
Luxembourg
+352 20 20 24 16
24 hours a day, 7 days a week
The Netherlands
+31 85 888 0596
24 hours a day, 7 days a week
Nigeria
+234 2012 278 883
24 hours a day, 7 days a week
Poland
+48 22 398 80 29
24 hours a day, 7 days a week
Portugal
+351 308 801 773
24 hours a day, 7 days a week
Slovakia
+421 2330 579 72
24 hours a day, 7 days a week
Slovenia
+386 1 888 80 16
24 hours a day, 7 days a week
South Africa
080 001 4676
24 hours a day, 7 days a week
Spain
+34 931 768 545
24 hours a day, 7 days a week
Swedish
+46 8 525 034 03
24 hours a day, 7 days a week
Switzerland
+41 435 082 011
24 hours a day, 7 days a week
United Kingdom
+44 20 3807 3798
24 hours a day, 7 days a week
International
+1 703 527 3887
24 hours a day, 7 days a week
EMEA
+44 20 3885 0382
24 hours a day, 7 days a week
Asia Pacific
+65 3163 8374
24 hours a day, 7 days a week
Central America
+55 55 8526 4930
24 hours a day, 7 days a week
South America
+55-11 4349 1359
24 hours a day, 7 days a week
US & Canada
+1 800 424 9300
24 hours a day, 7 days a week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
The mineral oils in the product contain < 3% DMSO extract (IP 346).
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 | 64742-54-7 | 10 - 15% | No |
| Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 | 64742-65-0 | 10 - 15% | No |
| Reaction products of diphenylamine with nonene, branched EC: 701-385-4 | 36878-20-3 | 5 - 10% | Yes |
| Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased EC: 701-251-5 | 122384-87-6 | 5 - 10% | Yes |
| Phosphorodithioic acid, mixed O,O-bis(1,3-dimethylbutyl and iso-Pr) esters, zinc salts EC: 283-392-8 | 84605-29-8 | 3 - 5% | Yes |
| Distillates (petroleum), solvent-refined heavy paraffinic EC: 265-090-8 | 64741-88-4 | 3 - 5% | No |
| Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 | 64742-54-7 | 3 - 5% | Yes |
| zinc bis[O,O-bis(2-ethylhexyl)] bis(dithiophosphate) EC: 224-235-5 | 4259-15-8 | 3 - 5% | Yes |
| reaction product of cocoalkyldiethanolamides and cocoalkylmonoglycerides and molybdenumtrioxide EC: 430-380-7 | 445409-27-8 | 1 - 2.9% | Yes |
| Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 | 64742-65-0 | 1 - 3% | Yes |
| Distillates (petroleum), hydrotreated light paraffinic EC: 265-158-7 | 64742-55-8 | 1 - 3% | No |
| Distillates (petroleum), solvent-dewaxed light paraffinic EC: 265-159-2 | --- | 1 - 3% | No |
| phenol, (tetrapropenyl) derivatives EC: 616-100-8 | 74499-35-7 | 0.1 - 0.3% | Yes |
The EC substance definition and related classification & labelling have been developed in the framework of the regulation (EC) No. 1907/2006 (REACH). The related CAS number (*) is used for the purposes of the international inventories present in Section 15 of the SDS. Please note some GHS hazard classifications listed above may not be applicable in your country or region and are shown for informational purposes only.
Notes
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs or vPvBs or have been assigned a workplace exposure limit and hence require reporting in this section.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: reduced fetal weight, increase in fetal deaths, skeletal malformations
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse. Continue to rinse for at least 15 minutes.
Symptoms: reduced fetal weight, increase in fetal deaths, skeletal malformations
Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.
Symptoms: No known significant effects or critical hazards.
Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: reduced fetal weight, increase in fetal deaths, skeletal malformations
Immediate Medical Attention
Get medical attention.
Medical Treatment
No specific treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use water spray (fog), foam, dry chemical or CO₂.
Do not use water jet.
In a fire or if heated, a pressure increase will occur and the container may burst. This material is harmful to aquatic life with long lasting effects. Fire water contaminated with this material must be contained and prevented from being discharged to any waterway, sewer or drain.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Take precautions to limit storage vessel surface temperature to below 121°C (250°F).
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for firefighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist. Provide adequate ventilation.
Stop leak if without risk. Move containers from spill area. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Dispose of via a licensed waste disposal contractor. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Absorb with an inert material and place in an appropriate waste disposal container.
Materials: Inert material, sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
HiTEC® 11500 Performance Additive
---
HiTEC® 11500 Performance Additive
UFI: VN97-U3ES-6Y66-XTJ7
HiTEC® 12200 Performance Additive
UFI: ATHT-S04A-Y95V-JW7V
HiTEC® 12200 Performance Additive
UFI: ATHT-S04A-Y95V-JW7V
HiTEC® 11170 Performance Additive
UFI: TXUR-J2EY-MT6F-A4C5
HiTEC® 12010 Performance Additive
UFI: W1JR-G5N9-U575-UFVN
HiTEC® 12010 Performance Additive
UFI: W1JR-G5N9-U575-UFVN
HiTEC® 11183 Performance Additive
UFI: DCJS-J0GD-G00F-WY7Y
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Avoid exposure - obtain special instructions before use. Avoid exposure during pregnancy. Do not handle until all safety precautions have been read and understood. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapor or mist. Avoid release to the environment. If during normal use the material presents a respiratory hazard, use only with adequate ventilation or wear appropriate respirator. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.
Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Store locked up. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
If user operations generate dust, fumes, gas, vapor or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits.
Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 480 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer's directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.
Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
High temperatures, sparks and open flames.
Strong oxidizing and reducing agents.
Hydrogen sulfide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HiTEC® 11600 Performance Additive?
The signal word is warning.
What is the physical form of HiTEC® 11600 Performance Additive?
HiTEC® 11600 Performance Additive is a liquid. [viscous] appearing as liquid. [viscous] with brown. [dark] color. It has not available. odor.
What is the solubility of HiTEC® 11600 Performance Additive?
Not available.
What is HiTEC® 11600 Performance Additive used for?
Formulation of additive packages, lubricants and greases - Industrial; General use of lubricants and greases in vehicles or machinery - Industrial; General use of lubricants and greases in vehicles or machinery - Professional
What are the hazard statements for HiTEC® 11600 Performance Additive?
This substance has 2 hazard statements:
- H361f: Suspected of damaging fertility.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of HiTEC® 11600 Performance Additive?
The melting point is Not available. and the boiling point is Not available..