Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Urinalysis Control (Positive)
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Quality control for urine analysis test strips and instruments.
Manufacturers & Suppliers
DIRUI Industrial Co., Ltd
manufacturer
3333 Yiju Street, New &High Tech. Development Zone, Changchun, Jilin 130103, P.R. China
Emergency Contacts
DIRUI Industrial Co., Ltd
+86-431-85835743
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N/A | --- | 0.2% | No |
| Glucose EC: 200-075-1 | 50-99-7 | 1% | No |
| Sodium chloride EC: 231-598-3 | 7647-14-5 | 0.5% | No |
| Hemoglobin EC: 293-254-9 | 9008-02-0 | 0.1% | No |
| Bovine serum albumin EC: 232-936-2 | 9048-46-8 | 0.7% | Yes |
| Ethyl acetoacetate EC: 205-516-1 | 141-97-9 | 0.9% | No |
| Sodium bilirubin EC: 231-555-9 | 7632-00-0 | 0.3% | Yes |
| Esterase EC: 232-773-7 | 9016-18-6 | 0.5% | Yes |
| Urea EC: 200-315-5 | 57-13-6 | 2% | No |
| Creatinine EC: 200-466-7 | 60-27-5 | 0.2% | No |
| Calcium(Ca) EC: 231-179-5 | 7440-70-2 | 0.1% | Yes |
| Water EC: 231-791-2 | 7732-18-5 | 93.5% | No |
0.1 percent of the mixture consists of component (s) of unknown toxicity.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Get medical attention for any breathing difficulty.
Wash off with soap and plenty of water.
Immediately flush eyes with plenty of water, lifting upper and lower eyelids occasionally. Get medical attention if irritation persists.
If large amounts were swallowed, give water to drink and get medical advice.
Immediate Medical Attention
If skin irritation or rash occurs, get medical advice/attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Not available.
No specific fire or explosion hazard.
Firefighter Protection
Wear self contained breathing apparatus for fire-fighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Provide adequate ventilation. Avoid inhalation of vapor. Avoid skin and eye contact. Refer to section 8 of SDS for personal protection details.
Do not let product enter drains.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Urinalysis Control (Negative)
---
Endocrine Urine Control
---
Serum Control
---
Urine Calibration Standard
---
Rapid fFN Level 1 / Negative Control Rapid fFN Level 2 / Positive Control
---
Alinity m HBV Low Positive Control Alinity m HBV High Positive Control
---
Alinity m STI Positive CTRL
---
H Series Urine Analyzer Cleaning Liquid (Concentrated type)
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes. Keep ignition sources away - Do not smoke. Protect against electrostatic charges.
Store in a cool location. Keep away from ignition sources. Store away from foodstuffs. Keep container tightly closed in a dry and well-ventilated place.
Do not eat, drink and smoke in work areas. Wash hands after use. Remove contaminated clothing and protective equipment before entering eating areas.
Keep ignition sources away - Do not smoke. Protect against electrostatic charges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle in accordance with good industrial hygiene and safety practice.
No special protective equipment required. If necessary, wear protective gloves.
No special protective equipment required. If necessary, wear protective glasses.
No special protective equipment required. If necessary, wear protective respiratory.
No special protective equipment required. If necessary, wear protective clothing.
Avoid discharge into the environment. According to local regulations, Federal and official regulations.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at room temperature in closed containers under normal storage and handling conditions.
The substance is stable under normal storage and handling conditions.
No dangerous reactions known.
Incompatible materials.
Strong oxidizing agents.
No hazardous decomposition products.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not regulated
- Shipping Name
- Not regulated
- Transport Class
- Not regulated
- Packing Group
- Not regulated
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Urinalysis Control (Positive)?
The signal word is no signal word.
What is the physical form of Urinalysis Control (Positive)?
Urinalysis Control (Positive) is a liquid appearing as liquid .
What is Urinalysis Control (Positive) used for?
Quality control for urine analysis test strips and instruments.
What is the melting point of Urinalysis Control (Positive)?
The melting point is > 723 K(CAS#7558-79-4/7558-80-7) .