NextSDS Logo
Safety Data Sheet EN

Shell Rimula R3 10W (CF)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Shell Rimula R3 10W (CF)
Product Code
001C4570

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Engine oil.

Uses advised against

This product must not be used in applications other than those listed in Section 1 without first seeking the advice of the supplier.

Manufacturers & Suppliers

B

Belgian Shell NV/SA

manufacturer

Kantersteen – Cantersteen 47, B-1000 Brussel - Bruxelles

(+32) 02508 9298

Emergency Contacts

Emergency Contact

+32 2 2167469

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Precautionary Statements

No precautionary phrases.
No precautionary phrases.
No precautionary phrases.
No precautionary phrases.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Highly refined mineral oils and additives. The highly refined mineral oil contains <3% (w/w) DMSO-extract, according to IP346.

Chemical Name CAS Number Concentration Hazardous
Interchangeable low viscosity base oil (<20,5 cSt @40°C) * --- 90% Yes
Sulphurised calcium phenate ** --- 3% Yes
Calcium alkaryl sulphonate** --- 0.99% Yes

contains one or more of the following CAS-numbers (REACH registration numbers): 64742-53-6 (01-2119480375-34), 64742-54-7 (01-2119484627-25), 64742-55-8 (01-2119487077-29), 64742-56-9 (01-2119480132-48), 64742-65-0 (01-2119471299-27), 68037-01-4 (01-2119486452-34), 72623-86-0 (01-2119474878-16), 72623-87-1 (01-2119474889-13), 8042-47-5 (01-2119487078-27), 848301-69-9 (01-0000020163-82), 68649-12-7 (01-2119527646-33), 151006-60-9 (01-2119523580-47), 163149-28-8 (01-2119543695-30), 64741-88-4 (01-2119488706-23), 64741-89-5 (01-2119487067-30).

Notes

Remarks : ** polymer exempt.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No treatment necessary under normal conditions of use. If symptoms persist, obtain medical advice.

Skin contact

Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available. If persistent irritation occurs, obtain medical attention.

Symptoms: Oil acne/folliculitis signs and symptoms may include formation of black pustules and spots on the skin of exposed areas.

Eye contact

Flush eye with copious quantities of water. Remove contact lenses, if present and easy to do. Continue rinsing. If persistent irritation occurs, obtain medical attention.

Ingestion

In general no treatment is necessary unless large quantities are swallowed, however, get medical advice.

Symptoms: Ingestion may result in nausea, vomiting and/or diarrhoea.

Immediate Medical Attention

If symptoms persist, obtain medical advice.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, water spray or fog. Dry chemical powder, carbon dioxide, sand or earth may be used for small fires only.

Unsuitable media

Do not use water in a jet.

Specific hazards

Hazardous combustion products may include: A complex mixture of airborne solid and liquid particulates and gases (smoke). Carbon monoxide may be evolved if incomplete combustion occurs. Unidentified organic and inorganic compounds.

Instructions

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Firefighter Protection

Proper protective equipment including chemical resistant gloves are to be worn; chemical resistant suit is indicated if large contact with spilled product is expected. Self-Contained Breathing Apparatus must be worn when approaching a fire in a confined space. Select fire fighter's clothing approved to relevant Standards (e.g. Europe: EN469).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

6.1.1 For non emergency personnel: Avoid contact with skin and eyes. 6.1.2 For emergency responders: Avoid contact with skin and eyes.

Environmental

Use appropriate containment to avoid environmental contamination. Prevent from spreading or entering drains, ditches or rivers by using sand, earth, or other appropriate barriers.

Cleanup methods

Slippery when spilt. Avoid accidents, clean up immediately. Reclaim liquid directly or in an absorbent. Soak up residue with an absorbent such as clay, sand or other suitable material and dispose of properly.

Materials: absorbent such as clay, sand or other suitable material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid prolonged or repeated contact with skin. Avoid inhaling vapour and/or mists. When handling product in drums, safety footwear should be worn and proper handling equipment should be used. Properly dispose of any contaminated rags or cleaning materials in order to prevent fires.

Storage

Keep container tightly closed and in a cool, well-ventilated place. Use properly labeled and closable containers. Store at ambient temperature.

Fire prevention

Properly dispose of any contaminated rags or cleaning materials in order to prevent fires. Proper grounding and bonding procedures should be used during all bulk transfer operations to avoid static accumulation.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Adequate ventilation to control airborne concentrations. Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated.

Hands

Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374, US: F739) made from the following materials may provide suitable chemical protection. PVC, neoprene or nitrile rubber gloves Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove material, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced. Personal hygiene is a key element of effective hand care. Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. Application of a non-perfumed moisturizer is recommended. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with preference for >480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same but recognize that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time maybe acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. Glove thickness should be typically greater than 0.35 mm depending on the glove make and model.

Eyes

If material is handled such that it could be splashed into eyes, protective eyewear is recommended. Approved to EU Standard EN166.

Respiratory

No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for combined particulate/organic gases and vapours [Type A/Type P boiling point > 65°C (149°F)] meeting EN14387 and EN143.

Skin/Body

Skin protection is not ordinarily required beyond standard work clothes. It is good practice to wear chemical resistant gloves.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Softening Point
---
Partition Coefficient
log Pow: > 6 (based on information on similar products)
Kinematic Viscosity
43 mm2/s (40,0 °C); 7 mm2/s (100 °C)
Evaporation Rate
Data not available
Physical State
Liquid at room temperature.
Lower Explosive Limit
Typical 1 % (V)
Bulk Density
---
Freezing Point
Data not available
Colour Intensity
---
Voc Content
---
Explosive Limits
---
Vapor Density
---
Odor Threshold
Data not available
Flammability
Not classified as flammable but will burn.
Colour
amber
Physical State Data
liquid
Solidification Point
-33 °C
Dynamic Viscosity
Data not available
Cloud Point
---
Vapor Pressure
< 0,5 Pa (20 °C) estimated value(s)
Form
---
Relative Evaporation Rate
---
Odor
Data not available
Density
885 kg/m3 (15,0 °C)
Melting Point
Data not available
Boiling Point
> 280 °C estimated value(s)
State Under Standard Conditions
---
Appearance
---
Decomposition Temperature
Data not available
Solubility In Water
negligible
Relative Density
0,885 (15 °C)
Solubility In Fat
---
Properties Status
---
Upper Explosive Limit
Typical 10 % (V)
Crystallisation Point
---
Solubility
---
Ph
Not applicable
Flash Point
219 °C Method: ASTM D92 (COC)
Auto Ignition Temperature
> 320 °C
Molecular Weight
---
Metal Corrosion
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable.

Reactivity

The product does not pose any further reactivity hazards in addition to those listed in the following sub-paragraph.

Hazardous reactions

No hazardous reaction is expected when handled and stored according to provisions

Avoid

Extremes of temperature and direct sunlight.

Incompatible

Strong oxidising agents.

Decomposition

No decomposition if stored and applied as directed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Recover or recycle if possible. Waste arising from a spillage or tank cleaning should be disposed of in accordance with prevailing regulations, preferably to a recognised collector or contractor.

Disposal

It is the responsibility of the waste generator to determine the toxicity and physical properties of the material generated to determine the proper waste classification and disposal methods in compliance with applicable regulations.

Waste Codes

13 02 05* EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

Refer to Section 7, Handling & Storage, for special precautions which a user needs to be aware of or needs to comply with in connection with transport.

IMDG

Refer to Section 7, Handling & Storage, for special precautions which a user needs to be aware of or needs to comply with in connection with transport.

IATA

Refer to Section 7, Handling & Storage, for special precautions which a user needs to be aware of or needs to comply with in connection with transport.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The regulatory information is not intended to be comprehensive. Other regulations may apply to this material.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Shell Rimula R3 10W (CF)?

The signal word is no signal word.

What is the physical form of Shell Rimula R3 10W (CF)?

Shell Rimula R3 10W (CF) is a liquid at room temperature. with amber color. It has data not available odor.

What is Shell Rimula R3 10W (CF) used for?

Engine oil.

What is the melting point of Shell Rimula R3 10W (CF)?

The melting point is Data not available and the boiling point is > 280 °C estimated value(s).