Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Microban Additive IB10
- Product Code
- R70000-016
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Biocidal product
Manufacturers & Suppliers
Microban Ltd
manufacturer
Point North, Park Plaza, Hayes Way, Heath Hayes, Cannock, Staffordshire, UK WS12 2DD
+44-1543-464-070
Emergency Contacts
Infotrac
01-352-323-5000
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Silver magnesium aluminum phosphate complex | --- | 99.5% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
When breathing is difficult, properly trained personnel may assist affected person by administering 100% oxygen. Get medical attention if any discomfort continues.
Symptoms: respiratory irritant
Take off contaminated clothing and shoes immediately. Wash off immediately with plenty of water for at least 15 minutes. Wash contaminated clothing before reuse. If irritation occurs seek medical attention.
Symptoms: May cause transitory mechanical dermatitis or irritation.
Rinse immediately with plenty of water for at least 15 minutes. Keep eye wide open while rinsing. Get medical attention.
Rinse out mouth with water. Do NOT induce vomiting unless directed by physician. Dilute stomach contents by slowly giving one to two glasses of water. Never give anything by mouth to an unconscious person. Get immediate medical attention.
Immediate Medical Attention
Get medical attention if any discomfort continues (inhalation); Get medical attention (eye); If irritation occurs seek medical attention (skin); Get immediate medical attention (swallowed).
Medical Treatment
Treat symptomatically
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to the local circumstances and the surrounding area. Material is non-combustible
Product is not combustible. Fire or excessive heat may produce toxic decomposition and combustion products.
Follow standard procedure for chemical fire
Firefighter Protection
In the event of a fire, wear (SCBA) self contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Avoid breathing vapors / mist / gas / dust. Avoid contact with the skin, eyes, clothing. Take off contaminated clothing and shoes immediately. Wash contaminated clothing before re-use. Prevent further leakage or spillage if safe to do so.
The product should not be allowed to enter drains, water courses or the soil.
Remove or clean up material in powder form if possible. Pick up and transfer to properly labelled containers.
Materials: suitable, closed containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid formation of dust. Avoid contact with skin, eyes and clothing. Avoid breathing dust, mist or vapor. Smoking, eating and drinking should be prohibited in the application area. Use only in an area equipped with a safety shower.
Store in original container. Store in cool dry well ventilated area. Keep containers tightly closed. Keep away from food, drink and animal food stuffs.
Smoking, eating and drinking should be prohibited in the application area.
Empty only into grounded containers. Ground packages prior to emptying.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas.
Impervious gloves. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. The choice of an appropriate glove does not only depend on its material but also on other quality features and is different from one producer to the other. The break through time depends amongst other things on the material, the thickness and the type of glove and therefore has to be measured for each case. Gloves must be inspected prior to use. Replace gloves when worn. Do not wear leather gloves.
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166 (EU). Tightly fitting safety goggles. Wear face-shield and protective suit for abnormal processing problems.
In the case of dust or aerosol formation use respirator with an approved filter to minimize inhalation of dust. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific workplace. Wear protective gloves / protective clothing/ eye protection / face protection.
The product should not be allowed to enter drains, water courses or the soil. If the product contaminates rivers and lakes or drains inform respective authorities. Prevent further leakage or spillage if safe to do so.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable Under recommended storage conditions
None known Under recommended storage conditions
None known at this time.
None known at this time
Strong acids
Combustion and decomposition products may be toxic
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3077
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S.
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Microban Additive IB10?
The signal word is warning.
What is the physical form of Microban Additive IB10?
Microban Additive IB10 is a powder appearing as powder with white color. It has odourless odor.
What is Microban Additive IB10 used for?
Biocidal product
What are the hazard statements for Microban Additive IB10?
This substance has 2 hazard statements:
- H400: Very toxic to aquatic life
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of Microban Additive IB10?
The melting point is 660° C and the boiling point is No data available.