Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SLOVINYL® EP 742
- Chemical Name
- Polyvinylchloride (polymer of vinylchloride)
Regulatory Identifiers
- CAS Number
- 75-01-4 Check regulations →
- EC Number
- 200-831-0 Check regulations →
- REACH No.
- 01-2119458772-30-0002
Identified Uses
It is used for coating and chemical foaming technology.
Manufacturers & Suppliers
FORTISCHEM a. s.
manufacturer
M.R. Štefánika 1, 972 71 NOVÁKY, Slovenská republika IČO 31616755
+421/46/568 1151, +421/46/568 1111
Emergency Contacts
NÁRODNÉ TOXIKOLOGICKÉ INFORMAČNÉ CENTRUM, FNsP Bratislava, pracovisko Kramáre Klinika pracovného lekárstva a toxikológie
+421 2 54774166
NÁRODNÉ TOXIKOLOGICKÉ INFORMAČNÉ CENTRUM, FNsP Bratislava, pracovisko Kramáre Klinika pracovného lekárstva a toxikológie
+421 911 166 066
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| PVC | 9002-86-2 | 97% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Fresh air. Fix the patient in calm and prevent from the undercooling.
Take off the contaminated clothing. Wash the skin with water and soap and apply skin - protective cream.
Wash off 10-15 min with clean water. Immediately summon doctor.
Rinse mouth, immediately summon doctor.
Immediate Medical Attention
Immediately summon doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
carbon dioxide, foam, sand, water spray. Extinguishing agent should be specified also with regard to the fire surroundings.
Exposure resulted from the combustion products and related gases.
Firefighter Protection
Self contained breathing apparatus and full protective clothing must be worn!
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Pick up and arrange disposal without creating dust. Keep in properly labelled containers.
Do not allow discharge to the sewerage system and water source.
Pick up and arrange disposal without creating dust.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
In case of tube transport the electrostatic charge is to be led away. Avoid dust formation. Do not eat, drink and smoke at workplace.
Keep in dry and good ventilated storage place. Protection should be provided against weather effect and sunlight.
Do not eat, drink and smoke at workplace.
In case of tube transport the electrostatic charge is to be led away.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ventilation of work places. Apply technical measures to comply with the occupational exposure limits.
protective gloves
protective glasses
In case of higher concentration use a respirator with the particle filter P2 (EN143).
protective clothing and shoes
Do not allow discharge to the sewerage system and water source.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The substance is stable under common conditions. It is resistant to acids, alkalis, mineral oils and aliphatic hydrocarbons.
no data available
if the storage conditions are performed, no spontaneous hazardous reactions occur in the product.
Higher temperature, naked flame, sparks and the other fire sources. Keep off the weather (effects (moisture, sun beams). Avoid direct contact with strong oxidizing agents.
strong oxidizing agents.
CO₂ and CO (in case of combustion)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SLOVINYL® EP 742?
The signal word is no signal word.
What is the physical form of SLOVINYL® EP 742?
SLOVINYL® EP 742 is a powder, solid material appearing as powder, solid material with white color. It has odorless odor.
What is the solubility of SLOVINYL® EP 742?
insoluble in organic solvents, soluble in chlorinated hydrocarbons, in tetrahydrofuran, 1.2 EDC, nitrobenzene, ketones, acetone, slightly soluble in esters and aromatic hydrocarbons, insoluble in fats.
What is SLOVINYL® EP 742 used for?
It is used for coating and chemical foaming technology.
What is the melting point of SLOVINYL® EP 742?
The melting point is no data available and the boiling point is no data available.