Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ADRAFOC CR-B
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Fire-resistant coating. For professional user /industrial user only.
Uses advised against
All uses not specified in this section or in section 7.3
Manufacturers & Suppliers
Assessors Del Ram d'Aigua, S.A.
manufacturer
Verge dels Dolors, 11-17, E-08107 Martorelles - Barcelona - Spain
(+34) 935 93 11 83
http://www.adrasa.com
Emergency Contacts
Emergency Contact
(+34) 93 593 19 53
office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances
Notes
None of the substances contained in the mixture are above the values fixed in Annex II of Regulation (EC) n°1907/2006
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of symptoms, move the person affected into fresh air.
In case of contact it is recommended to clean the affected area thoroughly with water and neutral soap. In case of modifications on the skin (stinging, redness, rashes, blisters,...), seek medical advice with this Safety data Sheet
Symptoms: stinging, redness, rashes, blisters
Rinse with water until the product has been eliminated. In case of problems, consult a doctor with the SDS of this product.
In case of consumption in large quantities, it is recommended to seek medical assistance.
Immediate Medical Attention
In case of consumption in large quantities, it is recommended to seek medical assistance. In case of modifications on the skin (stinging, redness, rashes, blisters,...), seek medical advice with this Safety data Sheet. In case of problems, consult a doctor with the SDS of this product.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
ABC Powder, water
Due to its non-flammable nature, the product does not present a fire risk under normal conditions of storage, manipulation and use.
Depending on the magnitude of the fire it may be necessary to use full protective clothing and individual respiratory equipment. Minimum emergency facilities and equipment should be available (fire blankets, portable first aid kit,...) in accordance with Directive 89/654/EC.
Firefighter Protection
Depending on the magnitude of the fire it may be necessary to use full protective clothing and individual respiratory equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Sweep up and shovel product or other means and place in container for reuse (preferred) or disposal
This product is not classified as hazardous to the environment. Keep product away from drains, surface and underground water.
Sweep up and shovel product or other means and place in container for reuse (preferred) or disposal
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Comply with the current legislation concerning the prevention of industrial risks. Keep containers hermetically sealed. Control spills and residues, destroying them with safe methods. Avoid leakages from the container. Maintain order and cleanliness where dangerous products are used.
Avoid sources of heat, radiation, static electricity and contact with food.
Do not eat or drink during the process, washing hands afterwards with suitable cleaning products.
Due to its non-flammable nature, the product does not present a fire risk under normal conditions of storage, manipulation and use.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves against minor risks (CE CAT I). Replace gloves in case of any sign of damage. For prolonged periods of exposure to the product for professional users/industrials, we recommend using CE III gloves in line with standards EN 420 and EN 374.
Panoramic glasses against liquid splash (CE CAT II). EN 166:2001, EN ISO 4007:2012. Clean daily and disinfect periodically according to the manufacturer's instructions. Use if there is a risk of splashing.
Filter mask for particles (CE CAT III). EN 149:2001+A1:2009. Replace when an increase in resistance to breathing is observed.
Work clothing (CE CAT I). Anti-slip work shoes (CE CAT II, EN ISO 20347:2012).
In accordance with the community legislation for the protection of the environment it is recommended to avoid environmental spillage of both the product and its container. For additional information see sub section 7.1.D
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Chemically stable under the conditions of storage, handling and use.
No hazardous reactions are expected because the product is stable under recommended storage conditions. See section 7.
Under the specified conditions, hazardous reactions that lead to excessive temperatures or pressure are not expected.
Shock and friction: Not applicable, Contact with air: Not applicable, Increase in temperature: Not applicable, Sunlight: Not applicable, Humidity: Not applicable
Avoid strong acids, Avoid alkalis or strong bases
See sub section 10.3, 10.4 and 10.5 to find out the specific decomposition products. Depending on the decomposition conditions, complex mixtures of chemical substances can be released: carbon dioxide (CO2), carbon monoxide and other organic compounds.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ADRAFOC CR-B?
The signal word is no signal word.
What is the physical form of ADRAFOC CR-B?
ADRAFOC CR-B is a solid appearing as powdery with white color.
What is ADRAFOC CR-B used for?
Fire-resistant coating. For professional user /industrial user only.
What is the melting point of ADRAFOC CR-B?
The melting point is 300 - 310 °C and the boiling point is Non-applicable.