01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Eco-flam PU-257
Product Form
Mixture
Product Code
DH1013

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial use, Professional use, Textile industries, Flame retardant

Uses advised against

No additional information available

Manufacturers & Suppliers

Devan Chemicals N.V. logo

Devan Chemicals N.V.

manufacturer

Ninoofsesteenweg 539, 9600 Ronse - België

+32 55 23 01 10

http://www.devan.net

Emergency Contacts

Centre Anti-Poisons/Antigifcentrum c/o Hôpital Central de la Base - Reine Astrid

+32 70 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of REACH annex II

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Allow breathing of fresh air. Allow the victim to rest.

Skin contact

Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse.

Eye contact

Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persist.

Ingestion

Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.

Immediate Medical Attention

Obtain emergency medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam. Dry powder. Carbon dioxide. Water spray. Sand.

Unsuitable media

Do not use a heavy water stream.

Instructions

Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire-fighting water from entering environment.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel.

Environmental

Prevent entry to sewers and public waters.

Cleanup methods

On land, sweep or shovel into suitable containers.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapour.

Storage

Keep only in the original container in a cool, well ventilated place away from : Keep container closed when not in use.

Hygiene

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Wear protective gloves

Eyes

Chemical goggles or safety glasses

Respiratory

Where exposure through inhalation may occur from use, respiratory protection equipment is recommended

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Boiling Point
Not applicable
Kinematic Viscosity
Not applicable
Voc Content
---
Solubility
---
Metal Corrosion
---
Relative Density
No data available
Solubility In Fat
---
Freezing Point
Not applicable
Odor Threshold
No data available
Appearance
---
Cloud Point
---
Upper Explosive Limit
No data available
Dynamic Viscosity
Not applicable
Physical State Data
solid
Odor
Not applicable.
Crystallisation Point
---
Relative Evaporation Rate
---
Explosive Limits
---
Melting Point
Not applicable
Flammability
Non flammable
Ph
5 (10g/l)
Vapor Pressure
No data available
Partition Coefficient
No data available
Molecular Weight
---
Form
---
Solubility In Water
1 g/l
Properties Status
---
Flash Point
Not applicable
Evaporation Rate
---
Physical State
Solid
Colour Intensity
---
Solidification Point
---
Auto Ignition Temperature
> 260 °C
Decomposition Temperature
> 300 °C
Colour
Colourless.
Lower Explosive Limit
No data available
Vapor Density
---
Softening Point
---
State Under Standard Conditions
---
Density
---
Bulk Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None under normal conditions.

Hazardous reactions

None under normal conditions.

Avoid

Direct sunlight. Extremely high or low temperatures.

Incompatible

Strong acids. Strong bases. Oxidizing agent.

Decomposition

fume. Carbon monoxide. Carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Eco-flam PU-257?

The signal word is no signal word.

What is the physical form of Eco-flam PU-257?

Eco-flam PU-257 is a solid with colourless. color. It has not applicable. odor.

What is Eco-flam PU-257 used for?

Industrial use, Professional use, Textile industries, Flame retardant

What is the melting point of Eco-flam PU-257?

The melting point is Not applicable and the boiling point is Not applicable.