Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 1-Butanol
- Product Code
- 423490000; 423490010; 423495000; 423490025
- Chemical Name
- 1-Butanol
- Synonyms
- n-Butanol; n-Butyl alcohol, Butan-1-ol
Regulatory Identifiers
- CAS Number
- 71-36-3 Check regulations →
- EC Number
- 200-751-6 Check regulations →
- REACH No.
- 01-2119484630-38
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Thermo Fisher Scientific
manufacturer
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Fisher Scientific UK
distributor
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Fisher Scientific AG
distributor
Neuhofstrasse 11, CH 4153 Reinach
+41 (0) 56 618 41 11
Emergency Contacts
Emergency Contact
001-800-227-6701
Emergency Contact
+32 14 57 52 11
Emergency Contact
001-201-796-7100
Emergency Contact
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Tox Info Suisse
145
24hr
Tox Info Suisse
+41-44 251 51 51
Chemtrec
0800 564 402
24h
Chemtrec
+41-43 508 20 11
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1-Butanol EC: 200-751-6 | 71-36-3 | 99% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water and drink afterwards plenty of water.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.
Do not use a solid water stream as it may scatter and spread fire.
Flammable. Risk of ignition. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Containers may explode when heated. Thermal decomposition can lead to release of irritating gases and vapors. Keep product and empty container away from heat and sources of ignition.
Keep product and empty container away from heat and sources of ignition.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment as required. Ensure adequate ventilation.
Should not be released into the environment.
Soak up with inert absorbent material. Keep in suitable, closed containers for disposal.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Ensure adequate ventilation. Do not get in eyes, on skin, or on clothing. Avoid ingestion and inhalation.
Keep containers tightly closed in a dry, cool and well-ventilated place. Keep away from heat, sparks and flame. Flammables area.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Keep away from heat, sparks and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Use explosion-proof electrical/ventilating/lighting/equipment. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Butyl rubber (> 480 minutes, 0.35 mm, EN 374), Nitrile rubber (> 480 minutes, 0.38 mm, Level 6), Neoprene (> 480 minutes, 0.45 mm), Viton (R) (> 480 minutes, 0.7 mm). Inspect gloves before use. Observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves.
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Organic gases and vapours filter Type A Brown conforming to EN14387. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask: Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141. When RPE is used a face piece Fit Test should be conducted
Long sleeved clothing.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
Hazardous polymerization does not occur. None under normal processing.
Keep away from open flames, hot surfaces and sources of ignition. Incompatible products.
Strong oxidizing agents. Reducing Agent. Acid chlorides. copper. Copper alloys. Acid anhydrides.
Carbon monoxide (CO). Carbon dioxide (CO₂).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1120
- Shipping Name
- BUTANOLS
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is 1-Butanol known by?
1-Butanol is also known as: n-Butanol; n-Butyl alcohol, Butan-1-ol
What is the hazard signal word for 1-Butanol?
The signal word is danger.
What is the physical form of 1-Butanol?
1-Butanol is a liquid appearing as colorless . It has alcohol-like odor.
What is 1-Butanol used for?
Laboratory chemicals.
What are the hazard statements for 1-Butanol?
This substance has 6 hazard statements:
- H226: Flammable liquid and vapor
- H302: Harmful if swallowed
- H315: Causes skin irritation
- H318: Causes serious eye damage
- H335: May cause respiratory irritation
- H336: May cause drowsiness or dizziness
What is the melting point of 1-Butanol?