Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Isopropyl acetate
- Product Code
- 537462
- Chemical Name
- Isopropyl acetate
Regulatory Identifiers
- CAS Number
- 108-21-4 Check regulations →
- REACH No.
- 01-2119537214-46-XXXX
Identified Uses
Laboratory chemicals, Manufacture of substances
Manufacturers & Suppliers
Merck Life Science BV/SRL
national supplier
Brusselsesteenweg 288, B-3090 OVERIJSE
+32 (0)3 899-1301
Emergency Contacts
CHEMTREC
+(32) 28 083237
Anti-poison centre
070 245245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| isopropyl acetate EC: 203-561-1 | 108-21-4 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air. Call in physician.
Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
After swallowing: caution if victim vomits. Keep airways free. Call a physician immediately.
Symptoms: Risk of aspiration! Pulmonary failure possible after aspiration of vomit.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide (CO2) Foam Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Carbon oxides. Combustible. Pay attention to flashback. Vapors are heavier than air and may spread along floors. Development of hazardous combustion gases or vapours possible in the event of fire. Forms explosive mixtures with air at ambient temperatures.
Remove container from danger zone and cool with water.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Collect, bind, and pump off spills. Take up with liquid-absorbent material (e.g. Chemizorb®). Dispose of properly. Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.
Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and sources of ignition.
Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance.
Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Splash contact: Material: butyl-rubber, Minimum layer thickness: 0,7 mm, Break through time: 60 min, Material tested: Butoject® (KCL 898)
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type ABEK. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Flame retardant antistatic protective clothing.
Do not let product enter drains. Risk of explosion.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Vapors may form explosive mixture with air.
Violent reactions possible with: Strong oxidizing agents, alkalines, Bases
Avoid moisture. Heat. Warming.
various plastics
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1220
- Shipping Name
- ISOPROPYL ACETATE
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Isopropyl acetate?
The signal word is danger.
What is the physical form of Isopropyl acetate?
Isopropyl acetate is a liquid with colorless color. It has pleasant, aromatic odor.
What is Isopropyl acetate used for?
Laboratory chemicals, Manufacture of substances
What are the hazard statements for Isopropyl acetate?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapor.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of Isopropyl acetate?
The melting point is -73 °C and the boiling point is 85 - 91 °C.