Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- THINNER CELLULOSIC 509
- Product Code
- 16763
- Chemical Name
- THINNER CELLULOSIC 509
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Several industrial applications ( Solvent, ...).
Uses advised against
Non identified.
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim into fresh air. Allow the affected person to rest. If not breathing, give artificial respiration. Take the patient immediately to the hospital.
Remove contaminated clothing. Rinse skin immediately with plenty of water. (shower if necessary). Consult doctor if irritation develops.
Rinse immediately thoroughly and long (at least 15 min.) with plenty of water. Remove contact lenses after a few minutes rinse. Consult eye doctor.
DO NOT INDUCE VOMITING. Rinse mouth with water. Seek medical attention IMMEDIATELY or take to hospital.
Immediate Medical Attention
Seek medical attention IMMEDIATELY or take to hospital.
Medical Treatment
For specialist advice doctors should contact the NVCI or the Belgian Poison center.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Extinguishing powder, Foam, Carbon dioxide (CO2), Water spray.
Heavy water stream.
Fire may liberate carbon oxides (CO) and smoke.
Apply water spray or fog to cool nearby equipment.
Firefighter Protection
Use self-contained breathing apparatus and wear protective clothes when in close proximity to fire.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Shut off leaks if without risks.
Shut off leaks if without risks. Dike in the spilled product as much as possible with inert material. Prevent entry of product in public water, sewers or soil.
Collect the spillage in closable, suitable disposal containers. Clean up any spills as soon as possible, using an inert absorbent material.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Attention: SKIN ABSORPTION! STRONG HYGIENE! Prevent exposure to (pregnant) women. Avoid breathing vapour and contact with skin, eyes and clothing. Wear recommended personal protective equipment. (See section 8) When using, do not eat, drink or smoke.
Keep only in the original, safely locked container in a cool, well ventilated and fireproof place. Store away from all heat sources, including direct sunlight. All dangerous products should be placed on a drip tray or should be barreled.
When using, do not eat, drink or smoke.
Remove all sources of ignition (open fire, sparks, smoking, ...). Use special care to avoid static electric discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The data for this section has not been processed yet.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal circumstances.
Reacts violently with oxidizing agents.
Vapor mixes readily with air forming explosive mixtures.
Heat, Flames, Sparks, Direct sunlight.
Oxidizing agents.
Carbon oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1993
- Shipping Name
- Flammable liquid, n.o.s., (contains Toluene and Acetone)
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for THINNER CELLULOSIC 509?
The signal word is danger.
What is the physical form of THINNER CELLULOSIC 509?
THINNER CELLULOSIC 509 is a liquid appearing as clear, colourless with colourless color. It has solvent odour odor.
What is THINNER CELLULOSIC 509 used for?
Several industrial applications ( Solvent, ...).
What are the hazard statements for THINNER CELLULOSIC 509?
This substance has 7 hazard statements:
- H225: Highly flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H361d: Suspected of damaging the unborn child.
- H373: May cause damage to organs through prolonged or repeated exposure.
What is the melting point of THINNER CELLULOSIC 509?