Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Aerosol 2K Fill in Serie N
- Product Code
- REZ511
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Paintwork
Manufacturers & Suppliers
Peter Kwasny GmbH
manufacturer
Heilbronner Str. 96, D-74831 Gundelsheim
0049-(0)6269-95-20
Emergency Contacts
Emergency Contact
+49 6269 95 20
National Poisons Information Service, Birmingham
(0) 12 15 07 55 88/9
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Bis(1,2,2,6,6-pentamethyl-4-piperidinyl) sebacate EC: 255-437-1 | 41556-26-7 | 1% | Yes |
| dimethyl ether EC: 204-065-8 | 115-10-6 | 50 - 100% | Yes |
| ethyl acetate EC: 205-500-4 | 141-78-6 | 10 - 25% | Yes |
| n-butyl acetate EC: 204-658-1 | 123-86-4 | 10 - 25% | Yes |
| Aliphatisches Polyisocyanat | 28182-81-2 | 5 - 10% | Yes |
| butyl glycollate EC: 230-991-7 | 7397-62-8 | 1 - 2.5% | Yes |
| Solvent naphtha (petroleum), light arom. benzene < 0,1% EC: 265-199-0 | 64742-95-6 | 1% | Yes |
| Methyl-1,2,2,6,6-pentamethyl-4-piperidylsebacat EC: 280-060-4 | 82919-37-7 | 1% | Yes |
| 1,2,4-trimethylbenzene EC: 202-436-9 | 95-63-6 | 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air and to be sure call for a doctor. In case of unconsciousness place patient stably in side position for transportation.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Water with full jet
Can form explosive gas-air mixtures.
Cool container whit water
Firefighter Protection
Mouth respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow product to reach sewage system or any water course. Inform respective authorities in case of seepage into water course or sewage system. Do not allow to enter sewers/ surface or ground water.
Do not flush with water or aqueous cleansing agents
Related Products
Similar products with comparable safety profiles
Aerosol 1K Fill in
---
Aerosol 2K Fill In + 100ml Lack 2K BHS CAT BLACK
---
Aerosol 2K Fill In + 100ml Lack 2K BHS CAT Yellow
---
Aerosol 2K Fill In + 100ml Lack 2K Epoxy Primer black (SPR64607)
---
Aerosol 2K Fill In + 100ml 2K Epoxy Primer beige
---
Aerosol 2K Fill In + 100ml Lack 2K Epoxy Primer yellow (SPR64132)
---
Aerosol 1K Fill-in befüllt mit 200 ml Imron Fleet Line Industry NC Topcoat
---
Aerosol 1K Fill-in befüllt mit 200 ml Lack Govaere Brugge
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat and direct sunlight. Ensure good ventilation/exhaustion at the workplace. Take note of emission threshold. Use only in well ventilated areas. Ensure good interior ventilation, especially at floor level. (Fumes are heavier than air).
Store in a cool location. Observe official regulations on storing packagings with pressurized containers. Protect from heat and direct sunlight.
Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Nitrile rubber, NBR. Penetration time of glove material: Gloves must be changed after every contamination. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact of a maximum of 15 minutes gloves made of the following materials are suitable: butyl rubber, 0,7mm
Tightly sealed goggles
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Half mask with combination filter, class A1P2 minimum, or breathing mask with outer air supply.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Reacts with acids, alkalis and oxidizing agents.
No further relevant information available.
No further relevant information available.
Possible in traces.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- 1950 AEROSOLS
- Transport Class
- 2
- Packing Group
- Void
Warning: Gases.
Warning: Gases.
Warning: Gases.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Aerosol 2K Fill in Serie N?
The signal word is na: r-phrases.
What is the physical form of Aerosol 2K Fill in Serie N?
Aerosol 2K Fill in Serie N is a aerosol appearing as aerosol with according to product specification color. It has characteristic odor.
What is Aerosol 2K Fill in Serie N used for?
Paintwork
What is the melting point of Aerosol 2K Fill in Serie N?
The melting point is Undetermined. and the boiling point is Not applicable, as aerosol..