NextSDS Logo
Safety Data Sheet EN

Crack Check CNF Cleaner (Aerosol)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Crack Check CNF Cleaner (Aerosol)
Product Form
Aerosol
Product Code
CNF A

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Cleans hard surfaces before and after penetrant application.

Manufacturers & Suppliers

D

Dynaflux, Inc.

manufacturer

241 Brown Farm Rd., Cartersville, GA 30120 U.S.A.

Emergency Contacts

Emergency Contact

800-255-3924

Emergency Contact

813-248-0585

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

GHS Pictograms

GHS04 - Compressed gas

GHS04

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H229 Pressurized container: may burst if heated
H351 Suspected of causing cancer

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Dichloromethane 75-09-2 --- Yes

H.M.I.S. Health: 2 Flammability: 0 Reactivity: 0 Special: - N.F.P.A. Health: 3 Flammability: 0 Reactivity: 0 Personal Protection: b

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air.

Skin contact

Flush with water. Wash with soap and water. Apply a lotion.

Eye contact

Flush with water for 15 minutes.

Ingestion

Do not induce vomiting. Give several large glasses of water.

Immediate Medical Attention

If irritation persists call a physician. Seek medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, CO2, Dry chemical

Specific hazards

Unusual Fire and Explosion Hazard: use a self contained breathing apparatus. Use water fog to cool containers to prevent rupturing.

Instructions

Use water fog to cool containers to prevent rupturing.

Firefighter Protection

use a self contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Small spill

Soak up with absorbent material, i.e. kitty litter, clay or dirt. Sweep up and place in a labeled closed container.

Large spill

Keep unauthorized people from the area. Use self contained breathing apparatus. Dike area and pump contents to a labeled, closed container. Absorb residue and sweep up. Place in a closed, labeled container.

Cleanup methods

Soak up, sweep up, pump contents, absorb residue

Materials: absorbent material, i.e. kitty litter, clay or dirt

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Storage

Leave in the shipping containers. Store in a cool dry place.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use mechanical ventilation in confined spaces.

Hands

protective gloves

Eyes

safety glasses

Respiratory

If vapor exceeds TLV use a approved respirator.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Dynamic Viscosity
---
Ph
---
Appearance
thin liquid
Density
---
Solubility In Water
---
Boiling Point
39.8°C
Lower Explosive Limit
---
Metal Corrosion
---
Upper Explosive Limit
---
Flash Point
---
Vapor Density
---
Melting Point
---
Bulk Density
---
Properties Status
---
Voc Content
---
State Under Standard Conditions
---
Vapor Pressure
47.33 KPA
Form
---
Flammability
---
Physical State
thin liquid
Cloud Point
---
Solidification Point
---
Explosive Limits
---
Solubility
---
Colour Intensity
---
Crystallisation Point
---
Relative Density
---
Solubility In Fat
---
Physical State Data
liquid
Molecular Weight
---
Decomposition Temperature
---
Odor
Chlorinated solvent
Evaporation Rate
---
Relative Evaporation Rate
---
Kinematic Viscosity
---
Partition Coefficient
1.25
Auto Ignition Temperature
---
Softening Point
---
Colour
---
Odor Threshold
---
Freezing Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Product is stable

Hazardous reactions

will not occur.

Avoid

Ignition sources, open flames, amines and strong bases.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
Aerosols, (Dichloromethane)
Transport Class
Class 2.2, 6.1
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Crack Check CNF Cleaner (Aerosol)?

The signal word is warning.

What is the physical form of Crack Check CNF Cleaner (Aerosol)?

Crack Check CNF Cleaner (Aerosol) is a thin liquid appearing as thin liquid . It has chlorinated solvent odor.

What is Crack Check CNF Cleaner (Aerosol) used for?

Cleans hard surfaces before and after penetrant application.

What are the hazard statements for Crack Check CNF Cleaner (Aerosol)?

This substance has 2 hazard statements:

  • H229: Pressurized container: may burst if heated
  • H351: Suspected of causing cancer