01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
EMKARATE™ RL 32-3MAF

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Refrigeration Lubricants.

Uses advised against

None identified.

Manufacturers & Suppliers

LUBRIZOL LIMITED logo

LUBRIZOL LIMITED

manufacturer

THE KNOWLE, NETHER LANE, HAZELWOOD, DERBYSHIRE, DE56 4AN, GB

(44) 01332-842211

http://www.mylubrizol.com

Emergency Contacts

CHEMTREC

(+1) 703 527 3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Compiled in accordance with CLP Regulation (EC) No 1272/2008, as retained and amended in UK law.

See Section 15 for Regulation (EC) No. 1907/2006 REACH Article 59(1). Candidate List (Substances of Very High Concern (SVHC))

Notes

This material has no known hazards under applicable laws.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove exposed person to fresh air if adverse effects are observed.

Skin contact

Wash with soap and water. If skin irritation occurs, get medical attention. Launder contaminated clothing before reuse. Wash with soap and water. If skin irritation occurs, get medical attention.

Eye contact

Any material that contacts the eye should be washed out immediately with water. If easy to do, remove contact lenses.

Ingestion

Treat symptomatically. Get medical attention.

Immediate Medical Attention

Get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material. CO2, dry chemical, foam, water spray, water fog.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

Keep away from heat, sparks and open flame. Water may cause splattering. Container may rupture on heating.

Instructions

No data available.

Firefighter Protection

Wear full protective firegear including self-containing breathing apparatus operated in the positive pressure mode with full facepiece, coat, pants, gloves and boots. Recommend wearing self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ventilate area if spilled in confined space or other poorly ventilated areas.

Large spill

Dike far ahead of larger spill for later recovery and disposal.

Environmental

Avoid release to the environment. Do not contaminate water sources or sewer. Environmental manager must be informed of all major spillages. Prevent further leakage or spillage if safe to do so.

Cleanup methods

Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from ignition sources such as heat, sparks and open flame. No smoking. Keep containers closed when not in use. Wash thoroughly after handling. Launder contaminated clothing before reuse. Empty container contains product residue which may exhibit hazards of product.

Storage

Store away from incompatible materials.

Hygiene

Observe good industrial hygiene practices. Wash thoroughly after handling. Launder contaminated clothing before reuse.

Fire prevention

Keep away from ignition sources such as heat, sparks and open flame. No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use material in well ventilated area only. Adequate ventilation should be provided so that exposure limits are not exceeded. Mechanical ventilation or local exhaust ventilation may be required.

Hands

Rubber (natural, latex). Polyvinyl chloride (PVC). Nitrile. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.

Eyes

If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.

Respiratory

Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites. Use respirator with an organic vapor cartridge if exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment.

Skin/Body

Long sleeve shirt is recommended. Wear apron or protective clothing in case of contact.

Environmental

No data available. See section 6 for details.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Ph
Not applicable
Flash Point
230 °C
Upper Explosive Limit
No data available.
Evaporation Rate
No data available.
Boiling Point
No data available.
Form
liquid
Solubility In Fat
---
Vapor Pressure
No data available.
Explosive Limits
---
Molecular Weight
---
Metal Corrosion
---
Physical State Data
liquid
Solubility In Water
Slightly Soluble
Solidification Point
---
Crystallisation Point
---
Kinematic Viscosity
31.2 mm2/s (40 °C); 5.6 mm2/s (100 °C)
Relative Evaporation Rate
---
Flammability
No data available.
Cloud Point
---
Physical State
liquid
Colour Intensity
---
Appearance
Colorless to yellow
Odor
Mild
Colour
Colorless to yellow
Relative Density
0.984 (20 °C)
Partition Coefficient
No data available.
Melting Point
---
Properties Status
---
Density
---
Auto Ignition Temperature
No data available.
Dynamic Viscosity
---
State Under Standard Conditions
---
Vapor Density
---
Odor Threshold
No data available.
Voc Content
No data available.
Softening Point
---
Lower Explosive Limit
No data available.
Decomposition Temperature
No data available.
Bulk Density
---
Freezing Point
No data available.
Solubility
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

No data available.

Hazardous reactions

Will not occur.

Avoid

Do not expose to excessive heat, ignition sources, or oxidizing materials.

Incompatible

Strong oxidizing agents.

Decomposition

Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, and other products of incomplete combustion.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for EMKARATE™ RL 32-3MAF?

The signal word is no signal word.

What is the physical form of EMKARATE™ RL 32-3MAF?

EMKARATE™ RL 32-3MAF is a liquid appearing as colorless to yellow with colorless to yellow color. It has mild odor.

What is EMKARATE™ RL 32-3MAF used for?

Refrigeration Lubricants.