NextSDS Logo
Safety Data Sheet EN

LPS® CFC Free (Aerosol)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LPS® CFC Free (Aerosol)
Product Form
Aerosol
Product Code
03116

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For Industrial Use Only Use according to manufacturer's directions.

Manufacturers & Suppliers

ITW Pro Brands. -GA logo

ITW Pro Brands. -GA

manufacturer

4647 Hugh Howell Rd. Tucker, GA United States

770-243-8800

www.itwprobrands.com

Emergency Contacts

Dykem/Dymon/Scrubs

1-800-535-5053

For_LPS & Other Brands

1-800-424-9300

Infotrac

1-352-323-3500

Chemtrec

+001 703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1
Skin Irrit. Cat. 2
STOT SE Cat. 3
Repr. Cat. 2

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H222 Extremely flammable aerosol. Pressurized container: may burst if heated.
H315 Causes skin irritation.
H336 May cause drowsiness or dizziness.
H361 Suspected of damaging fertility or the unborn child.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P261 Avoid breathing gas.
P264 Wash all exposed external body areas thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves and protective clothing.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P308 + P313 IF exposed or concerned: Get medical advice/ attention.
P312 Call a POISON CENTER/doctor/physician/first aider/if you feel unwell.
P332 + P313 If skin irritation occurs: Get medical advice/attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P405 Store locked up.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.
P501 Dispose of contents/container to authorised hazardous or special waste collection point in accordance with any local regulation.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

The data for this section has not been processed yet.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. Lay patient down. Keep warm and rested. Prostheses such as false teeth, which may block airway, should be removed, where possible, prior to initiating first aid procedures. If breathing is shallow or has stopped, ensure clear airway and apply resuscitation, preferably with a demand valve resuscitator, bag-valve mask device, or pocket mask as trained. Perform CPR if necessary. Transport to hospital, or doctor.

Skin contact

Flush skin and hair with running water (and soap if available). Seek medical attention in the event of irritation.

Eye contact

Immediately hold the eyelids apart and flush the eye with fresh running water. Ensure complete irrigation of the eye by keeping eyelids apart and away from eye and moving the eyelids by occasionally lifting the upper and lower lids. Seek medical attention without delay; if pain persists or recurs seek medical attention. Removal of contact lenses after an eye injury should only be undertaken by skilled personnel.

Ingestion

If spontaneous vomiting appears imminent or occurs, hold patient's head down, lower than their hips to help avoid possible aspiration of vomitus.

Immediate Medical Attention

Seek medical attention without delay; if pain persists or recurs seek medical attention. Seek medical attention in the event of irritation. Transport to hospital, or doctor.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol stable foam, Dry chemical powder, BCF (where regulations permit), Carbon dioxide, Water spray or fog - Large fires only. SMALL FIRE: Water spray, dry chemical or CO2. LARGE FIRE: Water spray or fog.

Specific hazards

Excessive pressures may develop in a gas cylinder exposed in a fire; this may result in explosion. Cylinders with pressure relief devices may release their contents as a result of fire and the released gas may constitute a further source of hazard for the fire-fighter. Cylinders without pressure-relief valves have no provision for controlled release and are therefore more likely to explode if exposed to fire. LIQUID and vapour are flammable. Moderate fire hazard when exposed to heat or flame. Vapour forms an explosive mixture with air. Moderate explosion hazard when exposed to heat or flame. Vapour may travel a considerable distance to source of ignition. Heating may cause expansion or decomposition leading to violent rupture of containers. Aerosol cans may explode on exposure to naked flame. Rupturing containers may rocket and scatter burning materials. Hazards may not be restricted to pressure effects. May emit acrid, poisonous or corrosive fumes. Vented gas is more dense than air and may collect in pits, basements.

Instructions

Alert Fire Brigade and tell them location and nature of hazard. May be violently or explosively reactive. Consider evacuation. Fight fire from a safe distance, with adequate cover. If safe, switch off electrical equipment until vapour fire hazard removed. Use water delivered as a fine spray to control fire and cool adjacent area. DO NOT approach cylinders suspected to be hot. Cool fire-exposed cylinders with water spray from a protected location. If safe to do so, remove containers from path of fire. The only safe way to extinguish a flammable gas fire is to stop the flow of gas. If the flow cannot be stopped, allow the entire contents of the cylinder to burn while cooling the cylinder and surroundings with water from a suitable distance. Extinguishing the fire without stopping the gas flow may permit the formation of ignitable or explosive mixtures with air.

Firefighter Protection

Wear breathing apparatus plus protective gloves. The need for proximity, entry and flash-over protection and special protective clothing should be determined for each incident, by a competent fire-fighting safety professional.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Clear area of personnel and move upwind. Alert Fire Brigade and tell them location and nature of hazard. Stop leak if safe to do so. Water spray or fog may be used to disperse / absorb vapour.

Small spill

Clean up all spills immediately. Avoid breathing vapours and contact with skin and eyes. Wipe up. If safe, damaged cans should be placed in a container outdoors, away from all ignition sources, until pressure has dissipated. Undamaged cans should be gathered and stowed safely.

Large spill

DO NOT exert excessive pressure on valve; DO NOT attempt to operate damaged valve. Clear area of personnel and move upwind. Alert Fire Brigade and tell them location and nature of hazard. May be violently or explosively reactive. Stop leak if safe to do so. Water spray or fog may be used to disperse / absorb vapour. Absorb or cover spill with sand, earth, inert materials or vermiculite. If safe, damaged cans should be placed in a container outdoors, away from ignition sources, until pressure has dissipated. Undamaged cans should be gathered and stowed safely. Collect residues and seal in labelled drums for disposal.

Environmental

Prevent, by any means available, spillage from entering drains or water courses

Cleanup methods

Wipe up. Absorb or cover spill with sand, earth, inert materials or vermiculite. Collect residues and seal in labelled drums for disposal.

Materials: sand, earth, inert materials or vermiculite

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid all personal contact, including inhalation. Wear protective clothing when risk of exposure occurs. Use in a well-ventilated area. Prevent concentration in hollows and sumps. DO NOT enter confined spaces until atmosphere has been checked. Avoid smoking, naked lights or ignition sources. Avoid contact with incompatible materials. When handling, DO NOT eat, drink or smoke. DO NOT incinerate or puncture aerosol cans. DO NOT spray directly on humans, exposed food or food utensils. Avoid physical damage to containers. Always wash hands with soap and water after handling. Work clothes should be laundered separately. Use good occupational work practice. Observe manufacturer's storage and handling recommendations contained within this SDS. Atmosphere should be regularly checked against established exposure standards to ensure safe working conditions are maintained.

Storage

Keep dry to avoid corrosion of cans. Store in original containers in approved flammable liquid storage area. DO NOT store in pits, depressions, basements or areas where vapours may be trapped. No smoking, naked lights, heat or ignition sources. Keep containers securely sealed. Contents under pressure. Store away from incompatible materials. Store in a cool, dry, well ventilated area. Avoid storage at temperatures higher than 40 deg C. Store in an upright position. Protect containers against physical damage. Check regularly for spills and leaks.

Hygiene

Always wash hands with soap and water after handling. Work clothes should be laundered separately. When handling, DO NOT eat, drink or smoke.

Fire prevention

Avoid smoking, naked lights or ignition sources. Do not cut, drill, grind, weld or perform similar operations on or near containers.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

CARE: Use of a quantity of this material in confined space or poorly ventilated area, where rapid build up of concentrated atmosphere may occur, could require increased ventilation and/or protective gear. Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. General exhaust is adequate under normal conditions. Provide adequate ventilation in warehouse or closed storage areas.

Hands

Wear general protective gloves, eg. light weight rubber gloves. No special equipment needed when handling small quantities. OTHERWISE: For potentially moderate exposures:

Eyes

Safety glasses with side shields ► Chemical goggles. [AS/NZS 1337.1, EN166 or national equivalent] ► Contact lenses may pose a special hazard; soft contact lenses may absorb and concentrate irritants.

Respiratory

Type AX Filter of sufficient capacity. (AS/NZS 1716 & 1715, EN 143:2000 & 149:2001, ANSI Z88 or national equivalent). Generally not applicable. Aerosols, in common with most vapours/ mists, should never be used in confined spaces without adequate ventilation.

Skin/Body

No special equipment needed when handling small quantities. OTHERWISE: • Overalls.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Density
0.67
Ph
Not Available
Auto Ignition Temperature
Not Available
Density
---
Properties Status
---
Colour Intensity
---
Freezing Point
---
Vapor Pressure
---
Evaporation Rate
<1 Ether = 1
Solubility In Water
Partly miscible
Explosive Limits
---
Lower Explosive Limit
Not Available
Flash Point
-32.8 °C
Boiling Point
57.93 °C
Solubility
---
Odor
Not Available
Vapor Density
3
Cloud Point
---
Partition Coefficient
Not Available
Molecular Weight
---
Appearance
Colourless
Upper Explosive Limit
Not Available
Solubility In Fat
---
Solidification Point
---
Crystallisation Point
---
Odor Threshold
Not Available
Flammability
HIGHLY FLAMMABLE.
Voc Content
95.8%
Physical State Data
gas
Metal Corrosion
---
Colour
---
Melting Point
Not Available
Dynamic Viscosity
---
Relative Evaporation Rate
---
Physical State
Compressed Gas
State Under Standard Conditions
---
Bulk Density
---
Kinematic Viscosity
<20.5 cSt
Decomposition Temperature
Not Available
Softening Point
---
Form
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Product is considered stable.

Reactivity

See section 7

Hazardous reactions

Hazardous polymerisation will not occur. See section 7

Avoid

Elevated temperatures. Presence of open flame. See section 7

Incompatible

See section 7

Decomposition

See section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
Aerosols, flammable
Transport Class
2.1
IMDG

Special provisions: 63 190 277 327 344 381 959; Limited Quantities: 1000 ml

IATA

Special provisions: A145 A167 A802

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LPS® CFC Free (Aerosol)?

The signal word is danger.

What is the physical form of LPS® CFC Free (Aerosol)?

LPS® CFC Free (Aerosol) is a compressed gas appearing as colourless . It has not available odor.

What is LPS® CFC Free (Aerosol) used for?

For Industrial Use Only Use according to manufacturer's directions.

What are the hazard statements for LPS® CFC Free (Aerosol)?

This substance has 4 hazard statements:

  • H222: Extremely flammable aerosol. Pressurized container: may burst if heated.
  • H315: Causes skin irritation.
  • H336: May cause drowsiness or dizziness.
  • H361: Suspected of damaging fertility or the unborn child.

What is the melting point of LPS® CFC Free (Aerosol)?

The melting point is Not Available and the boiling point is 57.93 °C.