Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ACMOS 81-400WE

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Release agent for phenolic resins

Manufacturers & Suppliers

ACMOS CHEMIE KG logo

ACMOS CHEMIE KG

manufacturer

Industriestrasse 49, D-28199 Bremen, Post-office box 10 10 69, D-28010 Bremen

+49-421-5189-0

www.acmos.com

Emergency Contacts

Emergency Contact

+49-551-19240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment.

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Emulsion of mineral oil and active ingredients in water

Chemical Name CAS Number Concentration Hazardous
Alcohols, tallow-, ethoxylated EC: 500-212-8 68439-49-6 1 - 5% Yes
zinc oxide EC: 215-222-5 1314-13-2 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. Consult a physician if necessary

Skin contact

Wash off with soap and water. Preventive skin protection. In the case of skin irritation or allergic reactions see a physician.

Eye contact

Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician. If eye irritation persists, consult a specialist.

Ingestion

Do not induce vomiting. Consult a physician. Never give anything by mouth to an unconscious person.

Immediate Medical Attention

Consult a physician if necessary.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. water, water spray, sand, alcohol-resistant foam, dry chemical, carbon dioxide (CO2)

Unsuitable media

None known

Specific hazards

No special precautions required. The product itself does not burn.

Firefighter Protection

No special precautions required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Small spill

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Take up mechanically and collect in suitable container for disposal.

Large spill

Dam up. Shovel into suitable container for disposal. Local authorities should be advised if significant spillages cannot be contained.

Environmental

Do not flush into surface water or sanitary sewer system.

Cleanup methods

Dam up. Shovel into suitable container for disposal. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Take up mechanically and collect in suitable container for disposal.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only in well-ventilated areas. When using, do not eat, drink or smoke.

Storage

Keep container tightly closed in a dry and well-ventilated place. Store at room temperature in the original container. Do not store outside. Avoid heating and direct sunlight.

Hygiene

When using, do not eat, drink or smoke.

Fire prevention

Fire-fighting equipment on the basis of class B.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Design of appropriate work processes and engineering controls and the use of adequate materials (model solutions as certified working methods, working appliance according to the state of the art, optimization of process / spray robots, working appliance for prevention of skin contact, models of working times). Provide appropriate exhaust ventilation at machinery. Where reasonably practicable this should be achieved by the use of local exhaust ventilation and good general extraction.

Hands

Use only chemical protective gloves with CE-status of category III in accordance to EN 374. Suitable materials at long term, direct contact (Recommended : Preventive index 6, accordingly > 480 min. permeation time in accordance to EN 374) : Nitrile rubber / NBR (CAMATRIL VELOURS® - Art. No. 730) - Layer thickness : 0,4 mm. Suitable materials at short term contact or splash (Recommended : Preventive index 3, accordingly > 60 min. permeation time in accordance to EN 374) : Disposable gloves of special nitrile rubber / NBR (DERMATRIL® P - Art. No. 743) - Layer thickness : 0,2 mm. Decrease wearing protection gloves to an inevitable degree to avoid skin rash. Technical and organizational protective actions have to be preferred. Wear under gloves made of cotton as possible. Change preventive gloves once by hour or use special skin-protective preparations for protective gloves carrier, e.g. physioderm® proGlove Before removing gloves clean them with soap and water. Dispose preventive gloves after defect or expiry of wearing time. Check protective gloves to proper condition before usage.

Eyes

safety glasses with side-shields (EN 166)

Respiratory

Breath protection at insufficient ventilation or prolonged exposition. Observe limited carrying time. The use of filter equipment requires a minimum oxygen content of 17 Vol-% in the surrounding atmosphere and that the maximum permitted gas concentration - normally 0,5 Vol-% - is not exceeded. Gas filtrating Half-face mask FFA (EN 405) Model 4251 (FFA1P1 - 1000 ml/m3) / 4255 (FFA2P2SL - 5000 ml/m3) - 3M, Internet : http://www.3m.com Half-face mask or Quarter-face mask with gas filter (EN 140) Filter type 6051 (A1 - 1000 ml/m3) / 6055 (A2 - 5000 ml/m3) - 3M, Internet : http://www.3m.com Full-face mask with gas filter (EN 136) Gas filter type : A, Indication colour : brown

Skin/Body

Textile workclothing and shoes without special requirements. (EN 340)

Environmental

Should not be released into the environment. Further information see under section 6.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Crystallisation Point
---
Form
---
Evaporation Rate
---
Solubility
---
Bulk Density
---
Density
0,96 g/cm³ DIN 51757
Voc Content
---
Upper Explosive Limit
--
Physical State
liquid
Cloud Point
---
Properties Status
---
Dynamic Viscosity
---
Lower Explosive Limit
--
Relative Density
---
Freezing Point
---
Odor Threshold
---
Odor
---
Kinematic Viscosity
> 7 mm²/s 3 EN ISO 2431 (at 23 °C)
Colour
light yellow
Molecular Weight
---
Ph
7,3
Metal Corrosion
---
Flash Point
> 101 °C EN ISO 2719
Solubility In Water
emulsifiable (at 20 °C)
Physical State Data
liquid
Vapor Density
---
Appearance
---
Solubility In Fat
---
Solidification Point
---
Colour Intensity
---
Auto Ignition Temperature
Not applicable
Partition Coefficient
Not applicable
Decomposition Temperature
---
Vapor Pressure
< 23 hPa Literary reference (at 20 °C)
Boiling Point
> 100 °C Literary reference
Flammability
---
Melting Point
< 0 °C Literary reference
Explosive Limits
---
Softening Point
---
State Under Standard Conditions
---
Relative Evaporation Rate
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at normal conditions

Avoid

none under normal use

Incompatible

none under normal use

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ACMOS 81-400WE?

The signal word is na: r-phrases.

What is the physical form of ACMOS 81-400WE?

ACMOS 81-400WE is a liquid with light yellow color.

What is ACMOS 81-400WE used for?

Release agent for phenolic resins

What is the melting point of ACMOS 81-400WE?

The melting point is < 0 °C Literary reference and the boiling point is > 100 °C Literary reference.