01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Eastman Tetrashield(TM) MP2103
Product Code
39667-00, P39667FJ, P39667FS, 50226031, P39667FE, P39667FT, P39667FH

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Coatings

Uses advised against

None known.

Manufacturers & Suppliers

Eastman Chemical Company logo

Eastman Chemical Company

manufacturer

200 South Wilcox Drive, 37660-5280 Kingsport

+14232292000

http://www.EASTMAN.com

Emergency Contacts

NCEC

+44 (0)1235 239 670

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

No hazardous ingredients

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. Treat symptomatically.

Skin contact

Wash off with soap and water.

Eye contact

In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.

Ingestion

Seek medical advice.

Immediate Medical Attention

If symptoms persist, call a physician.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, Carbon dioxide (CO2), Dry chemical

Unsuitable media

Do not use a solid water stream as it may scatter and spread fire.

Specific hazards

Avoid generating dust; fine dust dispersed in air in sufficient fighting concentrations, and in the presence of an ignition source is a potential dust explosion hazard.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear appropriate personal protective equipment.

Environmental

Avoid release to the environment.

Cleanup methods

Sweep up and shovel into suitable containers for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash thoroughly after handling. Use only in area provided with appropriate exhaust ventilation. Minimize dust generation and accumulation.

Storage

Keep container tightly closed.

Hygiene

Handle in accordance with good industrial hygiene and safety practice.

Fire prevention

Minimize dust generation and accumulation.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

Hands

Wear suitable gloves.

Eyes

Safety glasses

Respiratory

Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines. Wear respiratory protection when its use is identified for certain contributing scenario.

Skin/Body

Wear suitable protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
pellets
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
light yellow
Colour Intensity
---
Form
---
Odor
No data available
Odor Threshold
not determined
Ph
not determined
Melting Point
not determined
Boiling Point
not determined
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
not determined
Vapor Pressure
not determined
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
not determined
Lower Explosive Limit
not determined
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
387 °C
Solubility
---
Partition Coefficient
No data available
Solubility In Water
negligible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
not determined
Kinematic Viscosity
not determined
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None reasonably foreseeable.

Hazardous reactions

Stable

Avoid

Minimize dust generation and accumulation.

Incompatible

Strong oxidizing agents

Decomposition

Carbon monoxide Carbon dioxide (CO2)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Eastman Tetrashield(TM) MP2103?

The signal word is no signal word.

What is the physical form of Eastman Tetrashield(TM) MP2103?

Eastman Tetrashield(TM) MP2103 is a pellets with light yellow color. It has no data available odor.

What is Eastman Tetrashield(TM) MP2103 used for?

Coatings

What is the melting point of Eastman Tetrashield(TM) MP2103?

The melting point is not determined and the boiling point is not determined.