NextSDS Logo
Safety Data Sheet EN

TRYPSIN 0.25% EDTA

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TRYPSIN 0.25% EDTA
Product Code
25200056
Chemical Name
Not Applicable

Regulatory Identifiers

CAS Number
N/A
REACH No.
No registration number is given yet for this substance / substances in this mixture since the annual import quantity is less than one tonnage per annum or the transition period for its registration according to Article 23 of REACH has not yet expired.
UFI Code
Not Applicable

Identified Uses

For Research Use or Further Manufacturing. Not for diagnostic use or direct administration into humans or animals

Uses advised against

Not for consumer use.

Manufacturers & Suppliers

L

LIFE TECHNOLOGIES EUROPE BV

manufacturer

KWARTSWEG 2 2665 NN BLEISWIJK NETHERLANDS

31-(0)180 392 400

L

Life Technologies Limited

manufacturer

3 Fountain Drive Inchinnan Business Park Paisley PA4 9RF, UK

+44 (0)141 814 6100

Emergency Contacts

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

CHEMTREC

1-703-741-5970

CHEMTREC Ireland (Dublin)

+(353)-19014670

EN

CHEMTREC UK (London)

+(44)-870-8200418

EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Resp. Sens. Cat. 1

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapours/spray
P284 In case of inadequate ventilation wear respiratory protection
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing
P342 + P311 If experiencing respiratory symptoms: Call a POISON CENTER or doctor/physician
P501 Dispose of contents/ container to an approved waste disposal plant

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Trypsin EC: 232-650-8 9002-07-7 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. Call a doctor or poison control centre immediately. IF INHALED: Remove person to fresh air and keep comfortable for breathing.

Symptoms: May cause allergy or asthma symptoms or breathing difficulties if inhaled

Skin contact

Rinse skin with water.

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

Never give anything by mouth to an unconscious person. Do not induce vomiting without medical advice. Call a doctor or poison control centre immediately.

Immediate Medical Attention

Call a doctor or poison control centre immediately. If experiencing respiratory symptoms: Call a POISON CENTER or doctor/physician.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Carbon dioxide (CO2). Foam. Dry chemical.

Unsuitable media

No information available.

Specific hazards

Not known

Instructions

Standard procedure for chemical fires.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Avoid release to the environment.

Cleanup methods

Soak up with inert absorbent material.

Materials: inert absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Always wear recommended Personal Protective Equipment. Do not get in eyes, on skin, or on clothing. Do not ingest. If during normal use the material presents a respiratory hazard, use adequate ventilation and/or wear appropriate respirator. See section 8 for more information.

Storage

Keep in a dry, cool and well-ventilated place. Keep in properly labelled containers. Store in accordance with local regulations.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
No data
Colour Intensity
---
Form
---
Odor
No data
Odor Threshold
---
Ph
6-8
Melting Point
No data
Boiling Point
No data
Flash Point
No data
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data
Vapor Pressure
No data
Vapor Density
No data
Relative Density
No data
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
No data
Lower Explosive Limit
No data
Explosive Limits
---
Auto Ignition Temperature
No data
Decomposition Temperature
No data
Solubility
No data
Partition Coefficient
No data
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
No data
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None known.

Hazardous reactions

Hazardous reaction has not been reported.

Avoid

None under normal processing.

Incompatible

No dangerous reaction known under conditions of normal use.

Decomposition

None under normal use conditions.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TRYPSIN 0.25% EDTA?

The signal word is danger.

What is the physical form of TRYPSIN 0.25% EDTA?

TRYPSIN 0.25% EDTA is a liquid with no data color. It has no data odor.

What is the solubility of TRYPSIN 0.25% EDTA?

No data

What is TRYPSIN 0.25% EDTA used for?

For Research Use or Further Manufacturing. Not for diagnostic use or direct administration into humans or animals

What are the hazard statements for TRYPSIN 0.25% EDTA?

This substance has 1 hazard statement:

  • H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled

What is the melting point of TRYPSIN 0.25% EDTA?