NextSDS Logo
Safety Data Sheet EN

Cadmium chloride, anhydrous

CAS 10108-64-2
EC 233-296-7

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Cadmium chloride, anhydrous
Product Code
219140000; 219140100; 219141000; 219145000
Chemical Name
Cadmium chloride

Regulatory Identifiers

CAS Number
10108-64-2 Check regulations →
EC Number
233-296-7 Check regulations →

Identified Uses

Laboratory chemicals.

Uses advised against

No Information available

Manufacturers & Suppliers

F

Fisher Scientific UK

distributor

Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom

T

Thermo Fisher Scientific

distributor

Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium

Emergency Contacts

Emergency Contact

001-800-227-6701

Emergency Contact

+32 14 57 52 11

Emergency Number

001-201-796-7100

Emergency Number

+32 14 57 52 99

CHEMTREC

001-800-424-9300

CHEMTREC

001-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Acute Tox. Cat. 3 H301
Acute Tox. Cat. 2 H330
Muta. Cat. 1B H340
Carc. Cat. 1B H350
Repr. Cat. 1B H360FD
STOT RE Cat. 1 H372
Aquatic Acute Cat. 1 H400
Aquatic Chronic Cat. 1 H410

GHS Pictograms

GHS06 - Acute toxicity

GHS06

GHS08 - Serious health hazard

GHS08

GHS09 - Environmental hazard

GHS09

Hazard Statements

H301 Toxic if swallowed
H330 Fatal if inhaled
H340 May cause genetic defects
H350 May cause cancer
H360FD May damage fertility. May damage the unborn child
H372 Causes damage to organs through prolonged or repeated exposure
H410 Very toxic to aquatic life with long lasting effects

Precautionary Statements

P201 Obtain special instructions before use
P260 Do not breathe dust/fume/gas/mist/vapors/spray
P273 Avoid release to the environment
P280 Wear protective gloves/protective clothing/eye protection/face protection
P301 + P312 IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell
P304 + P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Cadmium chloride EC: 233-296-7 10108-64-2 95% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If breathing is difficult, give oxygen. Immediate medical attention is required. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. Get medical attention.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Do NOT induce vomiting. Call a physician or poison control center immediately.

Immediate Medical Attention

Immediate medical attention is required.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Dry chemical, CO₂, water spray or alcohol-resistant foam.

Unsuitable media

No information available.

Specific hazards

Non-combustible.

Instructions

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

Firefighter Protection

Wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Keep people away from and upwind of spill/leak. Evacuate personnel to safe areas.

Environmental

Do not flush into surface water or sanitary sewer system. Do not allow material to contaminate ground water system. Prevent product from entering drains. Avoid release to the environment. Collect spillage.

Cleanup methods

Sweep up and shovel into suitable containers for disposal.

Materials: suitable containers

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only under a chemical fume hood. Do not get in eyes, on skin, or on clothing. Do not ingest. If swallowed then seek immediate medical assistance. Wear personal protective equipment/face protection. Do not breathe (dust, vapor, mist, gas). Avoid dust formation.

Storage

Keep containers tightly closed in a dry, cool and well-ventilated place. Store under an inert atmosphere.

Hygiene

Handle in accordance with good industrial hygiene and safety practice.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only under a chemical fume hood. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source

Hands

Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. (minimum requirement)

Eyes

Goggles (European standard - EN 166)

Respiratory

When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted

Skin/Body

Long sleeved clothing.

Environmental

Prevent product from entering drains. Do not allow material to contaminate ground water system. Local authorities should be advised if significant spillages cannot be contained.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Powder Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
White
Colour
---
Colour Intensity
---
Form
---
Odor
No information available
Odor Threshold
No data available
Ph
No information available
Melting Point
568 °C / 1054.4 °F
Boiling Point
960 °C / 1760 °F
Flash Point
No information available
Freezing Point
---
Softening Point
No data available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable - Solid
Vapor Pressure
13 mbar @ 656 °C
Vapor Density
Not applicable
Relative Density
---
Bulk Density
No data available
Density
No data available
Flammability
No information available
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
Cadmium chloride: 5
Solubility In Water
1400 g/L (20°C)
Solubility In Fat
---
Molecular Weight
183.31
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Hygroscopic.

Reactivity

None known, based on information available

Hazardous reactions

None under normal processing. Hazardous Polymerization: No information available.

Avoid

Incompatible products. Excess heat. Exposure to moist air or water. Avoid dust formation.

Incompatible

Metals. Finely powdered metals.

Decomposition

Fumes. Toxic fumes.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN2570
Shipping Name
CADMIUM COMPOUND
Transport Class
6.1
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Cadmium chloride, anhydrous?

The signal word is danger.

What is the physical form of Cadmium chloride, anhydrous?

Cadmium chloride, anhydrous is a powder solid appearing as white . It has no information available odor.

What is Cadmium chloride, anhydrous used for?

Laboratory chemicals.

What are the hazard statements for Cadmium chloride, anhydrous?

This substance has 7 hazard statements:

  • H301: Toxic if swallowed
  • H330: Fatal if inhaled
  • H340: May cause genetic defects
  • H350: May cause cancer
  • H360FD: May damage fertility. May damage the unborn child
  • H372: Causes damage to organs through prolonged or repeated exposure
  • H410: Very toxic to aquatic life with long lasting effects

What is the melting point of Cadmium chloride, anhydrous?

The melting point is 568 °C / 1054.4 °F and the boiling point is 960 °C / 1760 °F.