Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Cadmium chloride, anhydrous
- Product Code
- 219140000; 219140100; 219141000; 219145000
- Chemical Name
- Cadmium chloride
Regulatory Identifiers
- CAS Number
- 10108-64-2 Check regulations →
- EC Number
- 233-296-7 Check regulations →
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Fisher Scientific UK
distributor
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Thermo Fisher Scientific
distributor
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Emergency Contacts
Emergency Contact
001-800-227-6701
Emergency Contact
+32 14 57 52 11
Emergency Number
001-201-796-7100
Emergency Number
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS06
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Cadmium chloride EC: 233-296-7 | 10108-64-2 | 95% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If breathing is difficult, give oxygen. Immediate medical attention is required. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device.
Wash off immediately with plenty of water for at least 15 minutes. Get medical attention.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Do NOT induce vomiting. Call a physician or poison control center immediately.
Immediate Medical Attention
Immediate medical attention is required.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry chemical, CO₂, water spray or alcohol-resistant foam.
No information available.
Non-combustible.
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Firefighter Protection
Wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Keep people away from and upwind of spill/leak. Evacuate personnel to safe areas.
Do not flush into surface water or sanitary sewer system. Do not allow material to contaminate ground water system. Prevent product from entering drains. Avoid release to the environment. Collect spillage.
Sweep up and shovel into suitable containers for disposal.
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
Cadmium chloride, anhydrous
CAS: 10108-64-2
Cadmium sulfate, anhydrous
CAS: 10124-36-4
Cadmium chloride hydrate, 99.99% (metals basis)
CAS: 654054-66-7
Cadmium acetate
CAS: 543-90-8
Cadmium metal
---
Cadmium
CAS: 7440-43-9
Cadmium sulfate, 8/3-hydrate
CAS: 7790-84-3
Cadmium oxide
CAS: 1306-19-0
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only under a chemical fume hood. Do not get in eyes, on skin, or on clothing. Do not ingest. If swallowed then seek immediate medical assistance. Wear personal protective equipment/face protection. Do not breathe (dust, vapor, mist, gas). Avoid dust formation.
Keep containers tightly closed in a dry, cool and well-ventilated place. Store under an inert atmosphere.
Handle in accordance with good industrial hygiene and safety practice.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only under a chemical fume hood. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. (minimum requirement)
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted
Long sleeved clothing.
Prevent product from entering drains. Do not allow material to contaminate ground water system. Local authorities should be advised if significant spillages cannot be contained.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Hygroscopic.
None known, based on information available
None under normal processing. Hazardous Polymerization: No information available.
Incompatible products. Excess heat. Exposure to moist air or water. Avoid dust formation.
Metals. Finely powdered metals.
Fumes. Toxic fumes.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2570
- Shipping Name
- CADMIUM COMPOUND
- Transport Class
- 6.1
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Cadmium chloride, anhydrous?
The signal word is danger.
What is the physical form of Cadmium chloride, anhydrous?
Cadmium chloride, anhydrous is a powder solid appearing as white . It has no information available odor.
What is Cadmium chloride, anhydrous used for?
Laboratory chemicals.
What are the hazard statements for Cadmium chloride, anhydrous?
This substance has 7 hazard statements:
- H301: Toxic if swallowed
- H330: Fatal if inhaled
- H340: May cause genetic defects
- H350: May cause cancer
- H360FD: May damage fertility. May damage the unborn child
- H372: Causes damage to organs through prolonged or repeated exposure
- H410: Very toxic to aquatic life with long lasting effects
What is the melting point of Cadmium chloride, anhydrous?
The melting point is 568 °C / 1054.4 °F and the boiling point is 960 °C / 1760 °F.