NextSDS Logo
Safety Data Sheet EN

Aluminum oxide, nanopowder, <50 nm particle size (TEM)

CAS 1344-28-1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Aluminum oxide, nanopowder, <50 nm particle size (TEM)
Product Form
nanopowder
Product Code
544833
Chemical Name
Aluminum oxide

Regulatory Identifiers

CAS Number
1344-28-1 Check regulations →
REACH No.
01-2119529248-35-XXXX

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Alumina EC: 215-691-6 --- --- No

Notes

Remarks : No hazardous ingredients

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

No special precautionary measures necessary.

Cleanup methods

Take up dry. Dispose of properly. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material: Nitrile rubber, Break through time: 480 min, Glove thickness: 0,11 mm, Protective index: Full contact / Splash contact, Manufacturer: KCL 741 Dermatril® L. Remarks: This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter : Filter type P2. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

No special precautionary measures necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

State Under Standard Conditions
---
Metal Corrosion
---
Appearance
---
Solidification Point
---
Crystallisation Point
---
Voc Content
---
Decomposition Temperature
No data available
Evaporation Rate
No data available
Solubility
---
Ph
No data available
Boiling Point
2.980 °C
Kinematic Viscosity
No data available
Solubility In Water
insoluble (20 °C) pH: 6 - 7 Method: OECD Test Guideline 105 GLP: yes
Vapor Density
---
Colour
No data available
Molecular Weight
101,96 g/mol
Melting Point
2.040 °C (Method: lit.)
Odor Threshold
---
Solubility In Fat
---
Softening Point
---
Flammability
No data available
Form
powder
Upper Explosive Limit
No data available
Auto Ignition Temperature
Not applicable
Freezing Point
---
Flash Point
Not applicable
Cloud Point
---
Physical State
solid
Vapor Pressure
No data available
Odor
No data available
Explosive Limits
---
Partition Coefficient
Not applicable for inorganic substances
Lower Explosive Limit
No data available
Density
3,94 g/cm3 (20 °C)
Dynamic Viscosity
No data available
Relative Evaporation Rate
---
Physical State Data
solid
Bulk Density
---
Colour Intensity
---
Properties Status
---
Relative Density
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

Exothermic reaction with: halogen-halogen compounds, Ethylene oxide, Fluorine, Hydrogen halides, vinyl acetate. Risk of explosion with: nitrates, halogen oxides.

Avoid

Exposure to moisture

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Aluminum oxide, nanopowder, <50 nm particle size (TEM)?

The signal word is no signal word.

What is the physical form of Aluminum oxide, nanopowder, <50 nm particle size (TEM)?

Aluminum oxide, nanopowder, <50 nm particle size (TEM) is a solid with no data available color. It has no data available odor.

What is Aluminum oxide, nanopowder, <50 nm particle size (TEM) used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of Aluminum oxide, nanopowder, <50 nm particle size (TEM)?

The melting point is 2.040 °C (Method: lit.) and the boiling point is 2.980 °C.