Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Iodonitrotetrazolium chloride
- Product Code
- I8377
Regulatory Identifiers
- CAS Number
- 146-68-9 Check regulations →
- REACH No.
- A registration number is not available for this substance as the substance or its uses are exempted from registration or the annual tonnage does not require a registration.
Identified Uses
Laboratory chemicals, Manufacture of substances
Manufacturers & Suppliers
Sigma-Aldrich
manufacturer
Sigma-Aldrich Chemie GmbH
manufacturer
Eschenstrasse 5, D-82024 TAUFKIRCHEN
+49 (0)89 6513-1130
Emergency Contacts
CHEMTREC Deutschland
0800 181 7059
CHEMTREC weltweit
+49 (0)696 43508409
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Substance name : INT EC-No. : 205-676-2
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2-(4-iodophenyl)-3-(4-nitrophenyl)-5-phenyltetrazolium chloride EC: 205-676-2 | 146-68-9 | 90 - 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Remove contact lenses.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Immediate Medical Attention
Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, Foam, Carbon dioxide (CO2), Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.
Suppress (knock down) gases/vapours/mists with a water spray jet.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains. Risk of explosion.
Take up dry.
Related Products
Similar products with comparable safety profiles
p-Nitrotetrazolium blue chloride
CAS: 298-83-9
2,3,5-Triphenyl tetrazolium chloride
CAS: 298-96-4
Thiazolyl blue tetrazolium bromide
CAS: 298-93-1
Nitro Blue Tetrazolium (chloride)
CAS: 298-83-9
Iodine
CAS: 7553-56-2
Iodine
CAS: 7553-56-2
Tetramethylammonium chloride
CAS: 75-57-0
Tin(IV) chloride
CAS: 7646-78-8
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharge. Change contaminated clothing. Wash hands after working with substance. For precautions see section 2.2.
Tightly closed. Keep away from heat and sources of ignition.
Change contaminated clothing. Wash hands after working with substance.
Keep away from open flames, hot surfaces and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Material : Nitrile rubber Break through time : 480 min Glove thickness : 0,11 mm Protective index : Full contact Manufacturer : KCL 741 Dermatril® L Material : Nitrile rubber Break through time : 480 min Glove thickness : 0,11 mm Protective index : Splash contact Manufacturer : KCL 741 Dermatril® L Remarks : This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter : Filter type P2 type: The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Flame retardant antistatic protective clothing.
Advice : Do not let product enter drains. Risk of explosion.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.
Violent reactions possible with: Oxidizing agents
no information available
No data available
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1325
- Shipping Name
- FLAMMABLE SOLID, ORGANIC, N.O.S. (Iodonitrotetrazolium chloride)
- Transport Class
- 4.1
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Iodonitrotetrazolium chloride?
The signal word is danger.
What is the physical form of Iodonitrotetrazolium chloride?
Iodonitrotetrazolium chloride is a solid with no data available color. It has no data available odor.
What is Iodonitrotetrazolium chloride used for?
Laboratory chemicals, Manufacture of substances
What are the hazard statements for Iodonitrotetrazolium chloride?
This substance has 2 hazard statements:
- H228: Flammable solid.
- H335: May cause respiratory irritation.
What is the melting point of Iodonitrotetrazolium chloride?
The melting point is 240 °C (Method: dec.) and the boiling point is No data available.