01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Propylene glycol
Product Code
PHR1051
Chemical Name
Propylene glycol

Regulatory Identifiers

CAS Number
57-55-6 Check regulations →
REACH No.
01-2119456809-23-XXXX

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma-Aldrich

manufacturer

M

Merck Life Science BV/SRL

manufacturer

Brusselsesteenweg 288, B-3090 OVERIJSE

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Formula : C₃H₈O₂ Molecular weight : 76,09 g/mol CAS-No. : 57-55-6 EC-No. : 200-338-0

Chemical Name CAS Number Concentration Hazardous
C₃H₈O₂ EC: 200-338-0 57-55-6 --- No

Notes

No components need to be disclosed according to the applicable regulations.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathed in, move person into fresh air. If not breathing, give artificial respiration.

Skin contact

Wash off with soap and plenty of water.

Eye contact

Flush eyes with water as a precaution.

Ingestion

Never give anything by mouth to an unconscious person. Rinse mouth with water.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Specific hazards

Carbon oxides

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid breathing vapors, mist or gas.

Environmental

No special environmental precautions required.

Cleanup methods

Keep in suitable, closed containers for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Keep container tightly closed in a dry and well-ventilated place. Store in cool place. Store at Room Temperature.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M). Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Respiratory

Respiratory protection not required. For nuisance exposures use type OV/AG (US) or type ABEK (EU EN 14387) respirator cartridges. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Skin/Body

Impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Environmental

No special environmental precautions required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Pressure
0,11 hPa at 20 °C
Flammability
---
Vapor Density
---
Relative Density
No data available
Colour Intensity
---
Cloud Point
---
Solubility In Water
at 25 °C soluble
Melting Point
-60 °C
Voc Content
---
Dynamic Viscosity
No data available
Metal Corrosion
---
Colour
colorless
Auto Ignition Temperature
No data available
Upper Explosive Limit
12,5 %(V)
Flash Point
103 °C - closed cup
State Under Standard Conditions
---
Relative Evaporation Rate
---
Explosive Limits
---
Ph
No data available
Freezing Point
---
Boiling Point
185 - 189 °C
Appearance
clear, viscous
Properties Status
---
Softening Point
---
Form
---
Partition Coefficient
log Pow: -0,8 at 25 °C
Crystallisation Point
---
Solidification Point
---
Solubility In Fat
---
Evaporation Rate
---
Density
1,03 g/cm³
Physical State
liquid, clear, viscous
Decomposition Temperature
No data available
Physical State Data
liquid
Odor Threshold
---
Molecular Weight
---
Odor
No data available
Bulk Density
---
Solubility
---
Kinematic Viscosity
No data available
Lower Explosive Limit
2,6 %(V)
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

No data available

Hazardous reactions

No data available

Avoid

No data available

Incompatible

Acid chlorides, Acid anhydrides, Oxidizing agents, Chloroformates, Reducing agents

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Propylene glycol?

The signal word is no signal word.

What is the physical form of Propylene glycol?

Propylene glycol is a liquid, clear, viscous appearing as clear, viscous with colorless color. It has no data available odor.

What is Propylene glycol used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of Propylene glycol?

The melting point is -60 °C and the boiling point is 185 - 189 °C.