NextSDS Logo
Safety Data Sheet EN

Pyridoxine

CAS 65-23-6

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Pyridoxine
Product Code
P5669

Regulatory Identifiers

CAS Number
65-23-6 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted from registration, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

M

Merck Life Science BV/SRL

manufacturer

Brusselsesteenweg 288, B-3090 OVERIJSE

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Pyridoxol EC: 200-603-0 65-23-6 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.

Instructions

Suppress (knock down) gases/vapors/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested: KCL 741 Dermatril® L Splash contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested: KCL 741 Dermatril® L This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P1 The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Form
Needles
Voc Content
---
Evaporation Rate
---
Kinematic Viscosity
No data available
Solubility In Water
soluble
Colour Intensity
---
Solidification Point
---
Decomposition Temperature
No data available
Appearance
---
Vapor Density
---
Cloud Point
---
Softening Point
---
Melting Point
Melting point/range: 159 - 162 °C - lit.
Bulk Density
---
Odor
No data available
Freezing Point
---
State Under Standard Conditions
---
Partition Coefficient
No data available
Relative Evaporation Rate
---
Crystallisation Point
---
Solubility In Fat
---
Molecular Weight
---
Density
No data available
Vapor Pressure
No data available
Flammability
No data available
Relative Density
No data available
Boiling Point
No data available
Odor Threshold
---
Explosive Limits
---
Solubility
---
Flash Point
Not applicable
Dynamic Viscosity
No data available
Lower Explosive Limit
No data available
Auto Ignition Temperature
No data available
Ph
No data available
Physical State Data
solid
Metal Corrosion
---
Colour
No data available
Upper Explosive Limit
No data available
Properties Status
---
Physical State
solid
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

Violent reactions possible with: Strong oxidizing agents

Avoid

Heat. Light.

Incompatible

Strong oxidizing agents

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Pyridoxine?

The signal word is no signal word.

What is the physical form of Pyridoxine?

Pyridoxine is a solid with no data available color. It has no data available odor.

What is Pyridoxine used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of Pyridoxine?

The melting point is Melting point/range: 159 - 162 °C - lit. and the boiling point is No data available.