Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Citral
- Product Code
- C83007
Regulatory Identifiers
- CAS Number
- 5392-40-5 Check regulations →
- REACH No.
- A registration number is not available for this substance as the substance or its uses are exempted from registration, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.
Identified Uses
Laboratory chemicals, Manufacture of substances
Manufacturers & Suppliers
Merck Life Science BV/SRL
manufacturer
Brusselsesteenweg 288 B-3090 OVERIJSE
+32 (0)3 899-1301
Emergency Contacts
CHEMTREC
+(32) 28 083237
Anti-poison centre
070 245245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| citral; 3,7-dimethyl-2,6-octadienal (cis-/trans-mixture of isomers) EC: 226-394-6 | 5392-40-5 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.
After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
After swallowing: caution if victim vomits. Keep airways free. Call a physician immediately.
Symptoms: Risk of aspiration! Pulmonary failure possible after aspiration of vomit.
Immediate Medical Attention
Consult a physician (skin contact). Call in ophthalmologist (eye contact). Call a physician immediately (swallowing).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide (CO2) Foam Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Carbon oxides Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up with liquid-absorbent material (e.g. Chemizorb® ). Dispose of properly. Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb® )
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2.2.
Tightly closed.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Full contact Material: butyl-rubber Minimum layer thickness: 0,7 mm Break through time: 480 min Material tested:Butoject® (KCL 898). Splash contact Material: Viton® Minimum layer thickness: 0,7 mm Break through time: 240 min Material tested:Vitoject® (KCL 890 / Aldrich Z677698, Size M). This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type ABEK. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature) .
Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical.
Violent reactions possible with: Aluminum alkalines Strong oxidizing agents acids
Strong heating.
Aluminum, Mild steel
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Shipping Name
- Not dangerous goods
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Citral?
The signal word is warning.
What is the physical form of Citral?
Citral is a clear, liquid with light yellow color. It has no data available odor.
What is Citral used for?
Laboratory chemicals, Manufacture of substances
What are the hazard statements for Citral?
This substance has 3 hazard statements:
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
What is the melting point of Citral?