NextSDS Logo
Safety Data Sheet EN

Buffer AW2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Buffer AW2

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals

Manufacturers & Suppliers

Q

QIAGEN GmbH

manufacturer

QIAGEN Str. 1, D-40724 Hilden

+49-(0)2103-29-0

QIAGEN Inc. logo

QIAGEN Inc.

national supplier

19300 Germantown Road, Germantown, MD 20874, USA

800-426-8157

http://support.qiagen.com

Emergency Contacts

CHEMTREC

1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

Not a hazardous substance or mixture.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

No hazardous ingredients

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If symptoms persist, call a physician.

Skin contact

Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. If symptoms persist, call a physician.

Eye contact

Remove contact lenses. Protect unharmed eye. Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

Ingestion

If accidentally swallowed obtain immediate medical attention. Rinse mouth with water. Never give anything by mouth to an unconscious person.

Immediate Medical Attention

If accidentally swallowed obtain immediate medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Specific hazards

Exposure to decomposition products may be a hazard to health.

Instructions

In the event of fire and/or explosion do not breathe fumes.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray.

Environmental

Do not allow uncontrolled discharge of product into the environment.

Cleanup methods

Keep in suitable, closed containers for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For personal protection see

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The choice of an appropriate glove does not only depend on its material but also on other quality features and is different from one producer to the other. Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact).

Eyes

Safety glasses

Skin/Body

Choose body protection according to the amount and concentration of the dangerous substance at the work place. Footwear protecting against chemicals

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid
Colour
No data available
Colour Intensity
---
Form
---
Odor
characteristic
Odor Threshold
No data available
Ph
7.5
Melting Point
No data available
Boiling Point
No data available
Flash Point
No data available
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
1.01 g/cm3
Flammability
---
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
not determined
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
No data available
Solubility In Water
No data available
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if stored and applied as directed.

Reactivity

No decomposition if stored and applied as directed.

Hazardous reactions

Stable under recommended storage conditions. Hazardous decomposition products formed under fire conditions.

Avoid

No data available

Incompatible

No data available

Decomposition

No decomposition if stored and applied as directed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Buffer AW2?

The signal word is no signal word.

What is the physical form of Buffer AW2?

Buffer AW2 is a liquid appearing as liquid with no data available color. It has characteristic odor.

What is Buffer AW2 used for?

Laboratory chemicals

What are the hazard statements for Buffer AW2?

This substance has 1 hazard statement:

  • Not a hazardous substance or mixture.

What is the melting point of Buffer AW2?

The melting point is No data available and the boiling point is No data available.