Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Lugol solution
Product Code
32922

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma

manufacturer

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Repr. Cat. 1B H360FD

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H360FD May damage fertility. May damage the unborn child.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
P308 + P313 IF exposed or concerned: Get medical advice/ attention.
P405 Store locked up.
P501 Dispose of contents/ container to an approved waste disposal plant.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
potassium iodide EC: 231-659-4 7681-11-0 0.3 - 1% Yes
Iodine EC: 231-442-4 7553-56-2 0.25 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air. Call in physician.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.

Eye contact

After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.

Ingestion

After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.

Firefighter Protection

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapours, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully with liquid-absorbent material (e.g. Chemizorb®). Dispose of properly. Clean up affected area.

Materials: liquid-absorbent material (e.g. Chemizorb®)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.

Storage

Tightly closed. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorised persons.

Hygiene

Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

required

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter : Filter type ABEK type: The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Freezing Point
---
Evaporation Rate
No data available
Physical State
liquid
Crystallisation Point
---
Solidification Point
---
Vapor Density
---
Odor
No data available
Decomposition Temperature
No data available
Kinematic Viscosity
No data available
Metal Corrosion
---
Voc Content
---
Dynamic Viscosity
No data available
Solubility In Fat
---
Auto Ignition Temperature
No data available
State Under Standard Conditions
---
Boiling Point
No data available
Melting Point
No data available
Relative Density
No data available
Appearance
---
Form
---
Vapor Pressure
No data available
Solubility In Water
(20 °C) soluble
Softening Point
---
Colour
No data available
Cloud Point
---
Ph
No data available
Upper Explosive Limit
No data available
Density
No data available
Molecular Weight
---
Odor Threshold
---
Colour Intensity
---
Solubility
---
Properties Status
---
Physical State Data
liquid
Partition Coefficient
No data available
Flammability
No data available
Lower Explosive Limit
No data available
Flash Point
No data available
Bulk Density
---
Relative Evaporation Rate
---
Explosive Limits
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

No data available

Hazardous reactions

Violent reactions possible with: The generally known reaction partners of water.

Avoid

no information available

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Lugol solution?

The signal word is danger.

What is the physical form of Lugol solution?

Lugol solution is a liquid with no data available color. It has no data available odor.

What is Lugol solution used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for Lugol solution?

This substance has 1 hazard statement:

  • H360FD: May damage fertility. May damage the unborn child.

What is the melting point of Lugol solution?

The melting point is No data available and the boiling point is No data available.