NextSDS Logo
Safety Data Sheet EN

Potassium iodate, ACS

CAS 7758-05-6
EC 231-831-9

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Potassium iodate, ACS
Product Code
11602
Chemical Name
Potassium iodate
Synonyms
Iodic acid, potassium salt.

Regulatory Identifiers

CAS Number
7758-05-6 Check regulations →
EC Number
231-831-9 Check regulations →

Identified Uses

Laboratory chemicals.

Uses advised against

No Information available

Manufacturers & Suppliers

A

Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)

manufacturer

Shore Road, Heysham, Lancashire, LA3 2XY, United Kingdom

+44 (0) 1524 850506

Emergency Contacts

Information US

001-800-227-6701

Information Europe

+32 14 57 52 11

Emergency Number US

001-201-796-7100

Emergency Number Europe

+32 14 57 52 99

CHEMTREC US

001-800-424-9300

CHEMTREC Europe

001-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Ox. Sol. Cat. 2 H272
Acute Tox. Cat. 4 H302
Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS03 - Oxidizing

GHS03

GHS07 - Health hazard

GHS07

Hazard Statements

H272 May intensify fire; oxidizer
H302 Harmful if swallowed
H319 Causes serious eye irritation

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking
P220 Keep away from clothing and other combustible materials
P280 Wear protective gloves/protective clothing/eye protection/face protection
P301 + P330 + P331 IF SWALLOWED: rinse mouth. Do NOT induce vomiting
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing
P312 Call a POISON CENTER or doctor if you feel unwell

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Iodic acid (HIO3), potassium salt EC: 231-831-9 7758-05-6 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.

Immediate Medical Attention

Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Flooding quantities of water.

Unsuitable media

No information available.

Specific hazards

Oxidizer: Contact with combustible/organic material may cause fire. Containers may explode when heated. Risk of explosion by shock, friction, fire or other sources of ignition. Runoff to sewer may create fire or explosion hazard. May ignite combustibles (wood paper, oil, clothing, etc.).

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Use personal protective equipment as required.

Environmental

Should not be released into the environment.

Cleanup methods

Sweep up and shovel into suitable containers for disposal.

Materials: suitable containers

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear personal protective equipment/face protection. Avoid dust formation. Do not get in eyes, on skin, or on clothing. Ensure adequate ventilation. Avoid ingestion and inhalation. Keep away from clothing and other combustible materials.

Storage

Keep in a dry, cool and well-ventilated place. Keep container tightly closed.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.

Fire prevention

Keep away from clothing and other combustible materials.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source

Hands

Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement)

Eyes

Goggles (European standard - EN 166)

Respiratory

When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask: Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted

Skin/Body

Wear appropriate protective gloves and clothing to prevent skin exposure. Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Powder Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Off-white
Colour
---
Colour Intensity
---
Form
---
Odor
Odorless
Odor Threshold
No data available
Ph
No information available
Melting Point
560 °C / 1040 °F
Boiling Point
No information available
Flash Point
No information available
Freezing Point
---
Softening Point
No data available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable - Solid
Vapor Pressure
No information available
Vapor Density
Not applicable
Relative Density
---
Bulk Density
No data available
Density
3.930
Flammability
No information available
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
log Pow -1 (Iodic acid (HIO3), potassium salt)
Solubility In Water
Soluble
Solubility In Fat
---
Molecular Weight
214
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Oxidizer: Contact with combustible/organic material may cause fire.

Reactivity

Yes

Hazardous reactions

Hazardous Polymerization: No information available. Hazardous Reactions: None under normal processing.

Avoid

Excess heat. Incompatible products. Combustible material.

Incompatible

combustible/organic material

Decomposition

Hydrogen iodide. Potassium oxides.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1479
Shipping Name
OXIDIZING SOLID, N.O.S.
Transport Class
5.1
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Potassium iodate, ACS known by?

Potassium iodate, ACS is also known as: Iodic acid, potassium salt.

What is the hazard signal word for Potassium iodate, ACS?

The signal word is danger.

What is the physical form of Potassium iodate, ACS?

Potassium iodate, ACS is a powder solid appearing as off-white . It has odorless odor.

What is Potassium iodate, ACS used for?

Laboratory chemicals.

What are the hazard statements for Potassium iodate, ACS?

This substance has 3 hazard statements:

  • H272: May intensify fire; oxidizer
  • H302: Harmful if swallowed
  • H319: Causes serious eye irritation

What is the melting point of Potassium iodate, ACS?