Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Potassium iodate, ACS
- Product Code
- 11602
- Chemical Name
- Potassium iodate
- Synonyms
- Iodic acid, potassium salt.
Regulatory Identifiers
- CAS Number
- 7758-05-6 Check regulations →
- EC Number
- 231-831-9 Check regulations →
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
manufacturer
Shore Road, Heysham, Lancashire, LA3 2XY, United Kingdom
+44 (0) 1524 850506
Emergency Contacts
Information US
001-800-227-6701
Information Europe
+32 14 57 52 11
Emergency Number US
001-201-796-7100
Emergency Number Europe
+32 14 57 52 99
CHEMTREC US
001-800-424-9300
CHEMTREC Europe
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS03
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Iodic acid (HIO3), potassium salt EC: 231-831-9 | 7758-05-6 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.
Immediate Medical Attention
Get medical attention if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Flooding quantities of water.
No information available.
Oxidizer: Contact with combustible/organic material may cause fire. Containers may explode when heated. Risk of explosion by shock, friction, fire or other sources of ignition. Runoff to sewer may create fire or explosion hazard. May ignite combustibles (wood paper, oil, clothing, etc.).
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Use personal protective equipment as required.
Should not be released into the environment.
Sweep up and shovel into suitable containers for disposal.
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
Potassium iodate
CAS: 7758-05-6
Potassium nitrite, ACS
CAS: 7758-09-0
Potassium Iodide
CAS: 7681-11-0
Potassium iodate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7758-05-6
Potassium sulfate anhydrous ACS
CAS: 7778-80-5
Potassium iodide solution 20 %, p.a.
---
Sodium iodate
CAS: 7681-55-2
Potassium Iodide pro analyse
UFI: RDC7-TR3N-PR0T-9A2G
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Avoid dust formation. Do not get in eyes, on skin, or on clothing. Ensure adequate ventilation. Avoid ingestion and inhalation. Keep away from clothing and other combustible materials.
Keep in a dry, cool and well-ventilated place. Keep container tightly closed.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Keep away from clothing and other combustible materials.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement)
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask: Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted
Wear appropriate protective gloves and clothing to prevent skin exposure. Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Oxidizer: Contact with combustible/organic material may cause fire.
Yes
Hazardous Polymerization: No information available. Hazardous Reactions: None under normal processing.
Excess heat. Incompatible products. Combustible material.
combustible/organic material
Hydrogen iodide. Potassium oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1479
- Shipping Name
- OXIDIZING SOLID, N.O.S.
- Transport Class
- 5.1
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Potassium iodate, ACS known by?
Potassium iodate, ACS is also known as: Iodic acid, potassium salt.
What is the hazard signal word for Potassium iodate, ACS?
The signal word is danger.
What is the physical form of Potassium iodate, ACS?
Potassium iodate, ACS is a powder solid appearing as off-white . It has odorless odor.
What is Potassium iodate, ACS used for?
Laboratory chemicals.
What are the hazard statements for Potassium iodate, ACS?
This substance has 3 hazard statements:
- H272: May intensify fire; oxidizer
- H302: Harmful if swallowed
- H319: Causes serious eye irritation
What is the melting point of Potassium iodate, ACS?