NextSDS Logo
Safety Data Sheet EN

Activated charcoal

CAS 7440-44-0

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Activated charcoal
Product Code
C9157

Regulatory Identifiers

CAS Number
7440-44-0 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted from registration, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Synonyms : Charcoal activated

Chemical Name CAS Number Concentration Hazardous
Charcoal activated EC: 231-153-3 7440-44-0 --- No

Notes

No components need to be disclosed according to the applicable regulations.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water Foam Carbon dioxide (CO2) Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Carbon oxides. Combustible. Risk of dust explosion. Development of hazardous combustion gases or vapours possible in the event of fire.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

No special precautionary measures necessary.

Cleanup methods

Take up dry. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharge.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

Fire prevention

Keep away from open flames, hot surfaces and sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). Full contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested: KCL 741 Dermatril® L Splash contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested: KCL 741 Dermatril® L

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P1 The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Environmental

No special precautionary measures necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flammability
May form combustible dust concentrations in air.
Melting Point
3.550 °C
Upper Explosive Limit
---
Ph
No data available
Kinematic Viscosity
No data available
Auto Ignition Temperature
---
Vapor Density
---
Odor
No data available
Solidification Point
---
Molecular Weight
---
Solubility In Fat
---
Voc Content
---
Appearance
---
Colour Intensity
---
Properties Status
---
Decomposition Temperature
---
Dynamic Viscosity
No data available
Flash Point
Not applicable
Relative Evaporation Rate
---
Physical State Data
---
Freezing Point
---
Colour
black
Physical State
solid
Boiling Point
No data available
Explosive Limits
---
Evaporation Rate
---
Cloud Point
---
Softening Point
---
Lower Explosive Limit
---
Vapor Pressure
1 hPa at 25 °C
Relative Density
---
Bulk Density
---
State Under Standard Conditions
---
Odor Threshold
---
Partition Coefficient
---
Solubility
---
Form
powder, granulescrystals
Metal Corrosion
---
Density
1,8 - 2,1 g/cm³
Crystallisation Point
---
Solubility In Water
insoluble
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

No data available

Avoid

no information available

Incompatible

Strong oxidizing agents

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Activated charcoal?

The signal word is no signal word.

What is the physical form of Activated charcoal?

Activated charcoal is a solid with black color. It has no data available odor.

What is Activated charcoal used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of Activated charcoal?

The melting point is 3.550 °C and the boiling point is No data available.