Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Sodium carbonate
- Product Code
- L13098
- Chemical Name
- Sodium carbonate
Regulatory Identifiers
- CAS Number
- 497-19-8 Check regulations →
- EC Number
- 207-838-8 Check regulations →
Identified Uses
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
Uses advised against
No Information available
Manufacturers & Suppliers
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
manufacturer
Shore Road, Heysham, Lancashire, LA3 2XY, United Kingdom
+44 (0) 1524 850506
Emergency Contacts
Emergency Contact
001-800-227-6701
Emergency Contact
+32 14 57 52 11
Emergency Contact
001-201-796-7100
Emergency Contact
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Sodium carbonate EC: 207-838-8 | 497-19-8 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration.
Wash off immediately with plenty of water for at least 15 minutes.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.
Clean mouth with water and drink afterwards plenty of water.
Immediate Medical Attention
Get medical attention. Get medical attention if symptoms occur. If symptoms arise, call a physician.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.
No information available.
Thermal decomposition can lead to release of irritating gases and vapors.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Use personal protective equipment as required.
Should not be released into the environment. See Section 12 for additional Ecological Information.
Sweep up and shovel into suitable containers for disposal.
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Do not get in eyes, on skin, or on clothing. Avoid ingestion and inhalation.
Keep containers tightly closed in a dry, cool and well-ventilated place.
Wash hands before breaks and immediately after handling the product. Handle in accordance with good industrial hygiene and safety practice.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure that eyewash stations and safety showers are close to the workstation location. Ensure adequate ventilation, especially in confined areas. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement)
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted
Long sleeved clothing. Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Hygroscopic.
None known, based on information available
Hazardous polymerization does not occur. None under normal processing.
Avoid dust formation. Incompatible products. Excess heat. Exposure to moist air or water.
Strong oxidizing agents. Strong acids. Fluorine. Metals.
Sodium oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Sodium carbonate?
The signal word is warning.
What is the physical form of Sodium carbonate?
Sodium carbonate is a solid appearing as white . It has odorless odor.
What is Sodium carbonate used for?
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
What are the hazard statements for Sodium carbonate?
This substance has 1 hazard statement:
- H319: Causes serious eye irritation
What is the melting point of Sodium carbonate?
The melting point is 854 °C / 1569.2 °F and the boiling point is 1600 °C / 2912 °F @ 760 mmHg.