NextSDS Logo
Safety Data Sheet EN

Cell Wash Solution II / Acid Wash

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Cell Wash Solution II / Acid Wash
Product Code
04880307190

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

R

Roche Diagnostics

manufacturer

9115 Hague Road, 46250 Indianapolis IN

1-800-428-5074

Emergency Contacts

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Corr. Cat. 1
Eye Dam. Cat. 1

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H314 Causes severe skin burns and eye damage.

Precautionary Statements

P264 Wash skin thoroughly after handling.
P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
P304 + P340 + P310 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor.
P305 + P351 + P338 + P310 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor.
P363 Wash contaminated clothing before reuse.
P405 Store locked up.
P501 Dispose of contents/ container to an approved waste disposal plant.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Acid wash Solution 2000ML

Chemical Name CAS Number Concentration Hazardous
1,2,3-Propanetricarboxylic acid, 2-hydroxy- 77-92-9 5 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

Skin contact

Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty. If on skin, rinse well with water. If on clothes, remove clothes.

Symptoms: corrosion of the skin

Eye contact

In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Continue rinsing eyes during transport to hospital. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Symptoms: Small amounts splashed into eyes can cause irreversible tissue damage and blindness.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Keep respiratory tract clear. Do NOT induce vomiting. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital.

Immediate Medical Attention

Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty. Take victim immediately to hospital.

Medical Treatment

The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

High volume water jet

Specific hazards

Do not allow run-off from fire fighting to enter drains or water courses.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Refer to protective measures listed in sections 7 and 8.

Environmental

Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. Local authorities should be advised if significant spillages cannot be contained.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal. Use neutralizing agents.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe vapors/dust. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area.

Storage

Keep container tightly closed in a dry and well-ventilated place.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No data available

Hands

Material: Protective gloves. Remarks: Wear appropriate protective gloves to prevent skin contact. Replace torn or punctured gloves promptly.

Eyes

Eye wash bottle with pure water. Tightly fitting safety goggles. Wear face-shield and protective suit for abnormal processing problems.

Skin/Body

Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Voc Content
---
Form
---
Appearance
liquid
Colour
No data available
Ph
ca. 1.75 (25 °C)
Physical State
liquid
Kinematic Viscosity
No data available
Evaporation Rate
No data available
Odor Threshold
No data available
Partition Coefficient
No data available
Solidification Point
---
Decomposition Temperature
No data available
Softening Point
---
Colour Intensity
---
Dynamic Viscosity
No data available
Melting Point
No data available
Solubility In Fat
---
Solubility
---
Odor
No data available
Upper Explosive Limit
No data available
Vapor Density
---
Bulk Density
---
State Under Standard Conditions
---
Relative Evaporation Rate
---
Solubility In Water
completely miscible
Auto Ignition Temperature
No data available
Flammability
The product is not flammable.
Density
---
Relative Density
---
Physical State Data
liquid
Crystallisation Point
---
Freezing Point
---
Metal Corrosion
---
Flash Point
does not flash
Explosive Limits
---
Lower Explosive Limit
No data available
Cloud Point
---
Molecular Weight
---
Properties Status
---
Boiling Point
No data available
Vapor Pressure
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No decomposition if stored and applied as directed.

Avoid

No data available

Incompatible

No data available

Decomposition

No data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Toxicity to fish : LC0 (Carassius auratus (goldfish)): 625 mg/l Toxicity to daphnia and other aquatic invertebrates : LC100 (Daphnia magna (Water flea)): 85 mg/l Toxicity to algae : EC0 (Scenedesmus quadricauda (Green algae)): 640 mg/l Toxicity to microorganisms : EC0 (Pseudomonas putida): > 10,000 mg/l Exposure time: 16 h

Persistence and degradability

1,2,3-Propanetricarboxylic acid, 2-hydroxy-: Biodegradability : Biodegradation: 98 % Exposure time: 7 d Method: OECD Test Guideline 302B

Bioaccumulative potential

1,2,3-Propanetricarboxylic acid, 2-hydroxy-: Partition coefficient: n-octanol/water : log Pow: -1.72

Mobility in soil

No data available

Other adverse effects

Environmental fate and pathways : Remarks: No data available Ozone-Depletion Potential : Regulation: 40 CFR Protection of Environment; Part 82 Protection of Stratospheric Ozone - CAA Section 602 Class I Substances Remarks: This product neither contains, nor was manufactured with a Class I or Class II ODS as defined by the U.S. Clean Air Act Section 602 (40 CFR 82, Subpt. A, App.A + B).

No data available regarding environmental fate and pathways. The product does not contain or use Class I or Class II ozone-depleting substances as defined by the U.S. Clean Air Act.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Send to a licensed waste management company. Can be disposed as waste water, when in compliance with local regulations.

Disposal

Do not contaminate ponds, waterways or ditches with chemical or used container.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Cell Wash Solution II / Acid Wash?

The signal word is danger.

What is the physical form of Cell Wash Solution II / Acid Wash?

Cell Wash Solution II / Acid Wash is a liquid appearing as liquid with no data available color. It has no data available odor.

What are the hazard statements for Cell Wash Solution II / Acid Wash?

This substance has 1 hazard statement:

  • H314: Causes severe skin burns and eye damage.

What is the melting point of Cell Wash Solution II / Acid Wash?

The melting point is No data available and the boiling point is No data available.