NextSDS Logo
Safety Data Sheet EN

Alere Afinion™ CRP Control

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Alere Afinion™ CRP Control

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Professional use, In Vitro Diagnostic Medical Device

Uses advised against

No additional information available

Manufacturers & Suppliers

Alere Technologies AS logo

Alere Technologies AS

national supplier

Kjelsåsveien 161, P.O. Box 6863 Rodeløkka, NO-0504 Oslo - Norway

+47-24056000

http://www.alere.com

Alere Technologies AS logo

Alere Technologies AS

manufacturer

Kjelsåsveien 161, P.O. Box 6863 Rodeløkka, NO-0504 Oslo - Norway

+47-24056000

http://www.alere.com

Emergency Contacts

National Poisons Information Service (Newcastle Unit)

+44 191 2606182

24H

National Poisons Information Service (Newcastle Unit)

+44 191 2606180

24H

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
sodium azide EC: 247-852-1 26628-22-8 0.1% Yes

Notes

None of the other components are subject to classification, or are present in quantities above regulatory disclosure limits

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No specific first aid measures noted.

Skin contact

Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse.

Eye contact

Immediately flush with plenty of water or eyewash solution for up to 10 minutes. Obtain medical attention if pain, blinking or redness persist.

Ingestion

(If swallowed, rinse mouth with water (only if the person is conscious)). Drink a few glasses of water or milk. Call a poison center or a doctor if you feel unwell.

Immediate Medical Attention

In all cases of doubt, or when symptoms persist, seek medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing media appropriate for surrounding fire.

Unsuitable media

None to our knowledge.

Specific hazards

Non flammable.

Instructions

Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire.

Firefighter Protection

Do not enter fire area without proper personal protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel.

Environmental

Prevent entry to sewers and public waters.

Cleanup methods

Take up liquid spill into absorbent material.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Wear appropriate personal protective equipment - see Section 8.

Storage

2 - 8 °C (36 - 46°F)

Hygiene

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide eyewash station.

Hands

Wear suitable gloves resistant to chemical penetration. Neoprene or nitrile rubber gloves. Layer thickness : 0,10mm. Breakthrough time : >480 min. STANDARD EN 374

Eyes

Not necessary under the recommended storage and handling conditions. Use splash goggles when eye contact due to splashing is possible. STANDARD EN 166

Respiratory

Respiratory protection not applicable

Skin/Body

Lab coat

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Yellow.
Colour Intensity
---
Form
---
Odor
No data available
Odor Threshold
No data available
Ph
6 - 10
Melting Point
---
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
No data available
Evaporation Rate
---
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
---
Flammability
Non flammable
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
Soluble in water.
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of use.

Reactivity

Stable under normal conditions.

Hazardous reactions

Not established.

Avoid

Avoid strong heating.

Incompatible

None to our knowledge.

Decomposition

No decomposition if stored normally.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Alere Afinion™ CRP Control?

The signal word is no signal word.

What is the physical form of Alere Afinion™ CRP Control?

Alere Afinion™ CRP Control is a liquid with yellow. color. It has no data available odor.

What is the solubility of Alere Afinion™ CRP Control?

Soluble in water.

What is Alere Afinion™ CRP Control used for?

Professional use, In Vitro Diagnostic Medical Device