01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RADCON Hand Cleaner
Product Code
03-302

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

T

THE SHERWIN-WILLIAMS COMPANY

manufacturer

Diversified Brands, Cleveland, OH 44115

(800) 832-2541

Emergency Contacts

THE SHERWIN-WILLIAMS COMPANY

(216) 566-2917

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Propane 74-98-6 2% No
Butane 106-97-8 3% No
Paraffin Oil 8012-95-1 2% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If affected, remove from exposure. Restore breathing. Keep warm and quiet.

Skin contact

Wash affected area thoroughly with soap and water. Remove contaminated clothing and launder before re-use.

Eye contact

Flush eyes with large amounts of water for 15 minutes. Get medical attention.

Ingestion

Do not induce vomiting. Get medical attention immediately.

Immediate Medical Attention

Get medical attention. Get medical attention immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon Dioxide, Dry Chemical, Alcohol Foam

Unsuitable media

Water spray may be ineffective.

Specific hazards

Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat. During emergency conditions overexposure to decomposition products may cause a health hazard.

Instructions

If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure build-up and possible autoignition or explosion when exposed to extreme heat.

Firefighter Protection

Full protective equipment including self-contained breathing apparatus should be used.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Remove all sources of ignition. Ventilate the area. Remove with inert absorbent.

Cleanup methods

Remove with inert absorbent.

Materials: inert absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from heat, sparks, and open flame. Vapors will accumulate readily and may ignite explosively. During use and until all vapors are gone: Keep area ventilated - Do not smoke - Extinguish all flames, pilot lights, and heaters - Turn off stoves, electric tools and appliances, and any other sources of ignition. Do not take internally. Keep out of the reach of children.

Storage

Contents under pressure. Do not puncture, incinerate, or expose to temperature above 120F. Heat from sunlight, radiators, stoves, hot water, and other heat sources could cause container to burst.

Fire prevention

Keep away from heat, sparks, and open flame. Extinguish all flames, pilot lights, and heaters - Turn off stoves, electric tools and appliances, and any other sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits. Refer to OSHA Standards 1910.94, 1910.107, 1910.108.

Hands

None required.

Eyes

Wear safety spectacles with unperforated sideshields.

Respiratory

If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator approved by NIOSH/MSHA for protection against materials in Section 2.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
---
Melting Point
Not Available
Boiling Point
<0 - 213 F / <-18 - 100 C
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Faster than ether
Vapor Pressure
---
Vapor Density
Heavier than air
Relative Density
0.97
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
N.A.
Solubility In Fat
---
Molecular Weight
---
Voc Content
5.58 %
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Hazardous reactions

Will not occur

Avoid

None known.

Incompatible

None known.

Decomposition

By fire: Carbon Dioxide, Carbon Monoxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RADCON Hand Cleaner?

The signal word is no signal word.

What is the physical form of RADCON Hand Cleaner?

RADCON Hand Cleaner is a liquid .

What is the melting point of RADCON Hand Cleaner?

The melting point is Not Available and the boiling point is <0 - 213 F / <-18 - 100 C.