Product Name
BP Diesel
Product Form
Oily liquid
Product Code
0000003079

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Fuel for compression ignition diesel engines.

Manufacturers & Suppliers

b

bp Oil New Zealand Limited

national supplier

Level 2, Stantec Building, 105 Carlton Gore Road, Newmarket, Auckland, New Zealand, 1023

Emergency Contacts

bp Oil New Zealand Limited

0800 800 027

Monday to Friday, 9am to 5pm

New Zealand National Poisons Centre

0800 805 111

New Zealand National Poisons Centre

0800 764 766

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 4
Carc. Cat. 2
Asp. Tox. Cat. 1
Aquatic Chronic Cat. 2

GHS Pictograms

GHS08 - Serious health hazard

GHS08

GHS09 - Environmental hazard

GHS09

Hazard Statements

H227 Combustible liquid.
H304 May be fatal if swallowed and enters airways.
H351 Suspected of causing cancer.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P273 Avoid release to the environment.
P280 Wear protective gloves, protective clothing, eye protection, face protection, or hearing protection.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or physician.
P308 + P313 IF exposed or concerned: Get medical attention.
P331 Do NOT induce vomiting.
P391 Collect spillage.
P405 Store locked up.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Complex mixture of middle distillate hydrocarbons, with carbon numbers in C10 to C28 range.

Chemical Name CAS Number Concentration Hazardous
Fuels, diesel 68334-30-5 100% No

Occupational exposure limits, if available, are listed in Section 8.

Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. Get medical attention.

Skin contact

In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Drench contaminated clothing with water before removing. This is necessary to avoid the risk of sparks from static electricity that could ignite contaminated clothing. Contaminated clothing is a fire hazard. Contaminated leather, particularly footwear, must be discarded. Clean shoes thoroughly before reuse. Get medical attention.

Eye contact

In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Eyelids should be held away from the eyeball to ensure thorough rinsing. Check for and remove any contact lenses. Get medical attention.

Ingestion

Do not induce vomiting. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately.

Symptoms: Aspiration hazard if swallowed. Can enter lungs and cause damage.

Immediate Medical Attention

Get medical attention immediately (for ingestion/unconscious). Injections through the skin resulting from contact with the product at high pressure constitute a major medical emergency. Surgical exploration should be undertaken without delay.

Medical Treatment

Treatment should in general be symptomatic and directed to relieving any effects. Product can be aspirated on swallowing or following regurgitation of stomach contents, and can cause severe and potentially fatal chemical pneumonitis, which will require urgent treatment. Gastric lavage should be undertaken only after endotracheal intubation. Monitor for cardiac dysrhythmias. Thorough and extensive debridement of the wound and underlying tissue is necessary to minimise tissue loss and prevent or limit permanent damage.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use water fog, foam, dry chemical or carbon dioxide extinguisher or spray.

Unsuitable media

Do not use water jet.

Specific hazards

Combustible liquid. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Vapours can form explosive mixtures with air. Vapours are heavier than air and can spread along the ground or float on water surfaces to remote ignition sources. Vapours may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back. This product is a poor conductor of electricity and can become electrostatically charged. If sufficient charge is accumulated, ignition of flammable mixtures can occur. This liquid may accumulate static electricity when filling properly-grounded containers. Static accumulation may be significantly increased by the presence of small quantities of water or other contaminants. Liquid will float and may reignite on surface of water.

Instructions

No action shall be taken involving any personal risk or without suitable training. Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear positive pressure self-contained breathing apparatus (SCBA) and full turnout gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Entry into a confined space or poorly ventilated area contaminated with vapour, mist or fume is extremely hazardous without the correct respiratory protective equipment and a safe system of work.

Small spill

Eliminate all ignition sources. Stop leak if without risk. Move containers from spill area. Absorb with an inert material and place in an appropriate waste disposal container. Use spark-proof tools and explosion-proof equipment.

Large spill

Eliminate all ignition sources. Stop leak if without risk. Move containers from spill area. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Dike spill area and do not allow product to reach sewage system and surface or ground water. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Use spark-proof tools and explosion-proof equipment.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Cleanup methods

Collect spilled product by absorbing with specific floating absorbents. Collect recovered product and other contaminated materials in suitable tanks or containers for recycle, recovery or safe disposal.

Materials: Inert material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Avoid exposure - obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not get in eyes or on skin or clothing. Do not swallow. Aspiration hazard if swallowed. Can enter lungs and cause damage. Never siphon by mouth. Avoid breathing vapour or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Empty containers retain product residue and can be hazardous. Do not reuse container. Avoid contact of spilt material and runoff with soil and surface waterways. Handling operations that can promote accumulation of static charges include but are not limited to: mixing, filtering, pumping at high flow rates, splash filling, creating mists or sprays, tank and container filling, tank cleaning, sampling, gauging, switch loading, vacuum truck operations. Restrict flow velocity according to API 2003 (2008), NFPA 77 (2007), and Laurence Britton, "Avoiding Static Ignition Hazards in Chemical Operations". To reduce potential for static discharge, ensure that all equipment is properly grounded and bonded and meets appropriate electrical classification requirements.

Storage

Store in accordance with local regulations. Store in a segregated and approved area. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Store locked up. Eliminate all ignition sources. Separate from oxidising materials. Keep container tightly closed and sealed until ready for use. Store and use only in equipment/containers designed for use with this product. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabelled containers.

Hygiene

Do not swallow. Never siphon by mouth.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Ensure that all equipment is properly grounded and bonded and meets appropriate electrical classification requirements. Eliminate all ignition sources. Tank headspaces should always be regarded as potentially flammable and care should be taken to avoid static electrical discharge and all ignition sources during filling, ullaging and sampling from storage tanks.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
>3
Bulk Density
---
State Under Standard Conditions
---
Vapor Density
---
Metal Corrosion
---
Cloud Point
---
Kinematic Viscosity
2 to 4.5 mm²/s (2 to 4.5 cSt) at 40°C
Softening Point
---
Ph
Not applicable. Based on Solubility in Water (Very slightly soluble in water)
Relative Evaporation Rate
---
Odor
Diesel fuel
Solubility In Water
Very slightly soluble
Flammability
---
Physical State
Oily liquid.
Solidification Point
---
Vapor Pressure
0.093 kPa (0.7 mm Hg) [20°C (68°F)]
Density
830 kg/m³ (0.83 g/cm³)
Odor Threshold
---
Dynamic Viscosity
---
Physical State Data
liquid
Colour
Clear Colourless. to Amber.
Voc Content
---
Melting Point
Not available.
Boiling Point
>180°C (>356°F)
Crystallisation Point
---
Colour Intensity
---
Auto Ignition Temperature
240°C (464°F)
Molecular Weight
---
Upper Explosive Limit
Upper: 5%
Solubility In Fat
---
Form
---
Lower Explosive Limit
Lower: 0.7%
Evaporation Rate
---
Freezing Point
---
Appearance
Oily liquid. Clear Colourless. to Amber.
Flash Point
Closed cup: >61.5°C (>142.7°F) [Pensky-Martens]
Properties Status
---
Decomposition Temperature
---
Solubility
---
Explosive Limits
---
Relative Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur. Under normal conditions of storage and use, hazardous polymerisation will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame). Avoid excessive heat.

Incompatible

Reactive or incompatible with the following materials: oxidising materials.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3082
Shipping Name
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Fuels, diesel)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for BP Diesel?

The signal word is danger.

What is the physical form of BP Diesel?

BP Diesel is a oily liquid. appearing as oily liquid. clear colourless. to amber. with clear colourless. to amber. color. It has diesel fuel odor.

What is BP Diesel used for?

Fuel for compression ignition diesel engines.

What are the hazard statements for BP Diesel?

This substance has 4 hazard statements:

  • H227: Combustible liquid.
  • H304: May be fatal if swallowed and enters airways.
  • H351: Suspected of causing cancer.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of BP Diesel?

The melting point is Not available. and the boiling point is >180°C (>356°F).