Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 4-Aminobenzoic acid
- Product Code
- A12673
- Chemical Name
- 4-Aminobenzoic acid
- Synonyms
- PABA
Regulatory Identifiers
- CAS Number
- 150-13-0 Check regulations →
- EC Number
- 205-753-0 Check regulations →
Identified Uses
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
Uses advised against
No Information available
Manufacturers & Suppliers
Thermo Fisher (Kandel) GmbH
manufacturer
Erlenbachweg 2, 76870 Kandel, Germany
+49 (0) 721 84007 280
Fisher Scientific AG
distributor
Neuhofstrasse 11, CH 4153 Reinach
+41 (0) 56 618 41 11
https://www.fishersci.ch/ch/en/customer-help-support/forms/email-us.html
Emergency Contacts
Emergency Contact
001-800-227-6701
Emergency Contact
+32 14 57 52 11
Emergency Contact
001-201-796-7100
Emergency Contact
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Tox Info Suisse
145
24hr
Tox Info Suisse
+41-44 251 51 51
Chemtrec
0800 564 402
24h
Chemtrec
+41-43 508 20 11
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| p-Aminobenzoic acid EC: 205-753-0 | 150-13-0 | 95% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.
Symptoms: trouble breathing, dizziness, lightheadedness
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
Symptoms: rash, itching, swelling, tingling of the hands and feet
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.
No information available.
Dust can form an explosive mixture with air. Fine dust dispersed in air may ignite.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Use personal protective equipment as required. Avoid dust formation.
Should not be released into the environment.
Sweep up and shovel into suitable containers for disposal.
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Ensure adequate ventilation. Do not get in eyes, on skin, or on clothing. Avoid ingestion and inhalation. Avoid dust formation.
Store under an inert atmosphere. Protect from direct sunlight. Keep refrigerated.
Handle in accordance with good industrial hygiene and safety practice.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Nitrile rubber, Neoprene, Natural rubber, PVC, Butyl rubber. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement)
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001; Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141. When RPE is used a face piece Fit Test should be conducted
Long sleeved clothing. Inspect gloves before use. observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. gloves with care avoiding skin contamination.
Prevent product from entering drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Air sensitive. Light sensitive.
Yes
Hazardous polymerization does not occur. None under normal processing.
Incompatible products. Excess heat. Avoid dust formation. Exposure to air. Exposure to light.
Strong oxidizing agents.
Nitrogen oxides (NOx). Carbon monoxide (CO). Carbon dioxide (CO₂).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is 4-Aminobenzoic acid known by?
4-Aminobenzoic acid is also known as: PABA
What is the hazard signal word for 4-Aminobenzoic acid?
The signal word is no signal word.
What is the physical form of 4-Aminobenzoic acid?
4-Aminobenzoic acid is a powder solid appearing as light yellow . It has no information available odor.
What is 4-Aminobenzoic acid used for?
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
What are the hazard statements for 4-Aminobenzoic acid?
This substance has 2 hazard statements:
- EUH208: May form combustible dust concentrations in air
- H412: Harmful to aquatic life with long lasting effects
What is the melting point of 4-Aminobenzoic acid?
The melting point is 186 - 189 °C / 366.8 - 372.2 °F and the boiling point is No information available.