Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Tribol GR CLS 2
- Product Form
- Grease
- Product Code
- 468712-DE03
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
General use of lubricants and greases in vehicles or machinery-Industrial; General use of lubricants and greases in vehicles or machinery-Professional; Grease for industrial applications. For specific application advice see appropriate Technical Data Sheet or consult our company representative.
Manufacturers & Suppliers
BP Europa SE
manufacturer
Erkelenzer Straße 20, D-41179 Mönchengladbach, Germany
+49 (0)800 7235-074
Emergency Contacts
Carechem
+44 (0) 1235 239 670
24/7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Highly refined mineral oil and additives. Thickening agent.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| calcium hydroxide EC: 215-137-3 | 1305-62-0 | --- | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. Get medical attention if symptoms occur.
Symptoms: Vapour inhalation under ambient conditions is not normally a problem due to low vapour pressure. Inhalation of oil mist or vapours at elevated temperatures may cause respiratory irritation.
Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Wash clothing before reuse. Clean shoes thoroughly before reuse. Get medical attention if irritation develops.
Symptoms: Defatting to the skin. May cause skin dryness and irritation. Prolonged or repeated contact can defat the skin and lead to irritation and/or dermatitis.
In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Eyelids should be held away from the eyeball to ensure thorough rinsing. Check for and remove any contact lenses. Get medical attention.
Symptoms: Causes serious eye irritation. Potential risk of transient stinging or redness if accidental eye contact occurs.
Do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Get medical attention if symptoms occur.
Symptoms: No known significant effects or critical hazards. Ingestion of large quantities may cause nausea and diarrhoea.
Immediate Medical Attention
Get medical attention if symptoms occur.
Medical Treatment
Treatment should in general be symptomatic and directed to relieving any effects. Surgical exploration should be undertaken without delay. Thorough and extensive debridement of the wound and underlying tissue is necessary to minimise tissue loss and prevent or limit permanent damage.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use water fog, alcohol resistant foam, dry chemical or carbon dioxide extinguisher or spray.
Do not use water jet. The use of a water jet may cause the fire to spread by splashing the burning product.
In a fire or if heated, a pressure increase will occur and the container may burst.
No action shall be taken involving any personal risk or without suitable training. Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Contact emergency personnel. No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material.
Stop leak if without risk. Move containers from spill area. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Contaminated absorbent material may pose the same hazard as the spilt product. If emergency personnel are unavailable, contain spilt material. Suction or scoop the spill into appropriate disposal or recycling vessels, then cover spill area with oil absorbent. Dispose of via a licensed waste disposal contractor.
Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.
Absorb with an inert material and place in an appropriate waste disposal container. Suction or scoop the spill into appropriate disposal or recycling vessels, then cover spill area with oil absorbent.
Materials: inert material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth, oil absorbent
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment. Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing vapour or mist. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Do not reuse container. Empty containers retain product residue and can be hazardous.
Store in a dry, cool and well-ventilated area, away from incompatible materials. Keep away from heat and direct sunlight. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Wash thoroughly after handling. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide exhaust ventilation or other engineering controls to keep the relevant airborne concentrations below their respective occupational exposure limits.
Recommended: Nitrile gloves. Continuous contact: Gloves with a minimum breakthrough time of 240 minutes, or >480 minutes if suitable gloves can be obtained. If suitable gloves are not available to offer that level of protection, gloves with shorter breakthrough times may be acceptable as long as appropriate glove maintenance and replacement regimes are determined and adhered to. Short-term / splash protection: Recommended breakthrough times as above. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm. Gloves: EN 420, EN 374
Safety glasses with side shields. Eye protection: EN 166
In case of insufficient ventilation, wear suitable respiratory equipment. For protection against metal working fluids, respiratory protection that is classified as "resistant to oil" (class R) or oil proof (class P) should be selected where appropriate. Depending on the level of airborne contaminants, an air-purifying, half-mask respirator (with HEPA filter) including disposable (P- or R-series) (for oil mists less than 50 mg/m³), or any powered, air-purifying respirator equipped with hood or helmet and HEPA filter (for oil mists less than 125 mg/m³). Where organic vapours are a potential hazard during metalworking operations, a combination particulate and organic vapour filter may be necessary. Respiratory protection: EN 529, EN 149, EN 405, EN 140 plus filter, EN 136 plus filter, EN 143, EN 14387
Use of protective clothing is good industrial practice. Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Cotton or polyester/cotton overalls will only provide protection against light superficial contamination that will not soak through to the skin. Overalls should be laundered on a regular basis. When the risk of skin exposure is high (e.g. when cleaning up spillages or if there is a risk of splashing) then chemical resistant aprons and/or impervious chemical suits and boots will be required.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data available for this product. Refer to Conditions to avoid and Incompatible materials for additional information.
Under normal conditions of storage and use, hazardous reactions will not occur. Under normal conditions of storage and use, hazardous polymerisation will not occur.
Avoid all possible sources of ignition (spark or flame).
oxidising materials
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Tribol GR CLS 2?
The signal word is warning.
What is the physical form of Tribol GR CLS 2?
Tribol GR CLS 2 is a grease. appearing as grease. with beige. color. It has not available. odor.
What is Tribol GR CLS 2 used for?
General use of lubricants and greases in vehicles or machinery-Industrial; General use of lubricants and greases in vehicles or machinery-Professional; Grease for industrial applications. For specific application advice see appropriate Technical Data Sheet or consult our company representative.
What are the hazard statements for Tribol GR CLS 2?
This substance has 1 hazard statement:
- H319: Causes serious eye irritation.
What is the melting point of Tribol GR CLS 2?
The melting point is Not available. and the boiling point is Not available..