NextSDS Logo
Safety Data Sheet EN

O2 1 %;N2 99 %

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
O2 1 %;N2 99 %
Product Form
Mixture
Product Code
000010012085
Synonyms
Prüfgas Sauerstoff, Stickstoff

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions. Perform risk assessment prior to use.

Uses advised against

Consumer use. Uses other than those listed above are not supported, contact your supplier for more information on other uses.

Manufacturers & Suppliers

L

Linde Gas GmbH

manufacturer

Carl-von-Linde-Platz 1, A-4651 Stadl-Paura, Austria

+43 50 4273

Emergency Contacts

UMCO/NCEC

+44 1865 407333

EN

UMCO/NCEC

+49 89 220 61012

DE

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Press. Gas (Comp.) H280

GHS Pictograms

GHS04 - Compressed gas

GHS04

Hazard Statements

H280 Contains gas under pressure; may explode if heated.

Precautionary Statements

P403 Store in a well-ventilated place.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Nitrogen EC: 231-783-9 7727-37-9 99% Yes
Oxygen EC: 231-956-9 7782-44-7 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.

Symptoms: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.

Skin contact

Adverse effects not expected from this product.

Eye contact

Adverse effects not expected from this product.

Ingestion

Ingestion is not considered a potential route of exposure.

Immediate Medical Attention

None.

Medical Treatment

None.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray or fog. Product does not burn, use fire control measures appropriate for the surrounding fire.

Unsuitable media

Do not use water jet to extinguish.

Specific hazards

Exposure to fire may cause containers to rupture/explode.

Instructions

Use fire control measures appropriate for the surrounding fire. Cool endangered receptacles with water spray jet from a protected position. Prevent water used in emergency cases from entering sewers and drainage systems. If possible, stop flow of product. Use water spray or fog to knock down fire fumes if possible. Move containers away from the fire area if this can be done without risk.

Firefighter Protection

In confined space use self-contained breathing apparatus. Standard protective clothing and equipment (Self Contained Breathing Apparatus) for fire fighters.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Act in accordance with local emergency plan. Try to stop release. Evacuate area. Ensure adequate air ventilation. Stay upwind. Wear self-contained breathing apparatus when entering area unless atmosphere is proved to be safe. Oxygen detectors should be used when asphyxiating gases may be released.

Environmental

Try to stop release.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

The product must be handled in accordance with good industrial hygiene and safety procedures. Only experienced and properly instructed persons should handle gases under pressure. Consider pressure relief device(s) in gas installations. Ensure the complete gas system was (or is regularly) checked for leaks before use. Do not smoke while handling product. Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. Contact your gas supplier if in doubt. Use only oxygen approved lubricants and oxygen approved sealings. Avoid suck back of water, acid and alkalis. Do not breathe gas. Avoid release of product into work area. Refer to supplier's container handling instructions. Do not allow backfeed into the container. Protect containers from physical damage; do not drag, roll, slide or drop. When moving cylinders, even for short distances, use a cart (trolley, hand truck, etc.) designed to transport cylinders. Leave valve protection caps in place until the container has been secured against either a wall or bench or placed in a container stand and is ready for use. If user experiences any difficulty operating valve discontinue use and contact supplier. Never attempt to repair or modify container valves or safety relief devices. Damaged valves should be reported immediately to the supplier. Keep container valve outlets clean and free from contaminants particularly oil and water. Replace valve outlet caps or plugs and container caps where supplied as soon as container is disconnected from equipment. Close container valve after each use and when empty, even if still connected to equipment. Never attempt to transfer gases from one cylinder/container to another. Never use direct flame or electrical heating devices to raise the pressure of a container. Do not remove or deface labels provided by the supplier for the identification of the content of the container. Suck back of water into the container must be prevented. Open valve slowly to avoid pressure shock.

Storage

Keep container below 50°C in a well ventilated place. Store containers in location free from fire risk and away from sources of heat and ignition. Containers should be stored in the vertical position and properly secured to prevent them from falling over. Observe all regulations and local requirements regarding storage of containers.

Hygiene

The product must be handled in accordance with good industrial hygiene and safety procedures. Do not smoke while handling product. Do not breathe gas.

Fire prevention

Do not smoke while handling product. Never use direct flame or electrical heating devices to raise the pressure of a container.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate general and local exhaust ventilation. Oxygen detectors should be used when asphyxiating gases may be released. Systems under pressure should be regularly checked for leakages. Consider the use of a work permit system e.g. for maintenance activities.

Hands

Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risks, performance level 1 or higher. Recommended types include wrist gloves from leather or synthetic material with equivalent performance, fabric gloves, fabric gloves with leather palms.

Eyes

Wear safety glasses with side shields. Standard EN 166 - Personal eye-protection - specifications

Respiratory

Self contained breathing apparatus is recommended, where unknown exposure may be expected, e.g. during maintenance activities on installation systems. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. When indicated by a risk assessment, Respiratory Protective Equipment must be used. The selection of the Respiratory Protective Device (RPD) must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected RPD.

Skin/Body

Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.

Environmental

None necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State Data
gas
Voc Content
---
Freezing Point
Not applicable
Solidification Point
---
Lower Explosive Limit
Not available
Softening Point
---
Solubility In Fat
---
Relative Evaporation Rate
---
Crystallisation Point
---
Colour
Colourless.
Explosive Limits
---
Odor Threshold
Odour threshold is subjective and inadequate to warn of overexposure.
Physical State
Gas
Decomposition Temperature
Not applicable.
Kinematic Viscosity
Not applicable for gases and gas mixtures.
Partition Coefficient
Not available (Log Kow); Not applicable for gas mixtures (Log Pow).
Metal Corrosion
---
Melting Point
Not applicable for gases and gas mixtures.
Ph
Not applicable for gases and gas mixtures.
Form
Compressed gas
Appearance
---
Solubility
---
Colour Intensity
---
Vapor Density
---
Boiling Point
Not applicable for gas mixtures. It is technically not possible to determine the boiling point or range of this mixture. Component with lowest boiling point: Nitrogen -196 °C
Odor
Odourless.
Solubility In Water
Not known, but considered to have low solubility.
State Under Standard Conditions
---
Cloud Point
---
Properties Status
---
Density
Not applicable
Dynamic Viscosity
Not applicable for gases and gas mixtures.
Bulk Density
---
Flammability
Non flammable.
Relative Density
Not applicable
Auto Ignition Temperature
Non flammable.
Vapor Pressure
Not applicable.
Molecular Weight
---
Evaporation Rate
---
Upper Explosive Limit
Not available
Flash Point
Not applicable for gases and gas mixtures.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Data for mixtures are not available. This mixture contains components with the following reactivity : Violently oxidises organic material.

Hazardous reactions

No additional information available

Avoid

Avoid moisture in installation systems.

Incompatible

For additional information on compatibility refer to ISO 11114.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1956
Shipping Name
COMPRESSED GAS, N.O.S. (Nitrogen, Oxygen)
Transport Class
2.2
Packing Group
Not applicable
ADR

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation, - Ensure that containers are firmly secured, - Ensure valve is closed and not leaking, - Ensure valve outlet cap nut or plug (where provided) is correctly fitted, - Ensure valve protection device (where provided) is correctly fitted.

IMDG

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation, - Ensure that containers are firmly secured, - Ensure valve is closed and not leaking, - Ensure valve outlet cap nut or plug (where provided) is correctly fitted, - Ensure valve protection device (where provided) is correctly fitted.

IATA

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation, - Ensure that containers are firmly secured, - Ensure valve is closed and not leaking, - Ensure valve outlet cap nut or plug (where provided) is correctly fitted, - Ensure valve protection device (where provided) is correctly fitted.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is O2 1 %;N2 99 % known by?

O2 1 %;N2 99 % is also known as: Prüfgas Sauerstoff, Stickstoff

What is the hazard signal word for O2 1 %;N2 99 %?

The signal word is warning.

What is the physical form of O2 1 %;N2 99 %?

O2 1 %;N2 99 % is a gas with colourless. color. It has odourless. odor.

What is O2 1 %;N2 99 % used for?

Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions. Perform risk assessment prior to use.

What are the hazard statements for O2 1 %;N2 99 %?

This substance has 1 hazard statement:

  • H280: Contains gas under pressure; may explode if heated.

What is the melting point of O2 1 %;N2 99 %?

The melting point is Not applicable for gases and gas mixtures. and the boiling point is Not applicable for gas mixtures. It is technically not possible to determine the boiling point or range of this mixture. Component with lowest boiling point: Nitrogen -196 °C.