Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MOBIL 1 FS X1 5W-50
- Product Code
- 2015101010Z7, 486811-60
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Engine oil
Uses advised against
None unless specified elsewhere in this SDS.
Manufacturers & Suppliers
ExxonMobil Petroleum & Chemical BV
manufacturer
POLDERDIJKWEG, B-2030 Antwerpen, Belgium
+32 3 790 3111
http://www.msds.exxonmobil.com
ExxonMobil Petroleum & Chemical BV
manufacturer
POLDERDIJKWEG, B-2030 Antwerpen, Belgium
0800 028 2851
http://www.msds.exxonmobil.com
Emergency Contacts
Emergency Contact
(+44) 870 8200418
24h
National Poison Control Centre
111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1-Decene, tetramer, mixed with 1-decene trimer, hydrogenated EC: 614-695-9 | 68649-12-7 | 5 - 10% | Yes |
| 2-PENTANOL, 4-METHYL-, HYDROGEN PHOSPHORODITHIOATE, ZINC SALT EC: 218-679-9 | 2215-35-2 | 0.1 - 1% | Yes |
| C14-16-18 ALKYL PHENOL EC: 931-468-2 | --- | 0.1 - 1% | Yes |
| DISTILLATES, HEAVY, C18-50 - BRANCHED, CYCLIC AND LINEAR EC: 482-220-0 | 848301-69-9 | 30 - 40% | Yes |
| maleic anhydride EC: 203-571-6 | 108-31-6 | 0.1% | Yes |
| PHOSPHORODITHIOIC ACID, MIXED 0,0 BIS (1,3-DIMETHYLBUTYL AND ISO- PR)ESTERS, ZINC SALTS EC: 283-392-8 | 84605-29-8 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from further exposure. For those providing assistance, avoid exposure to yourself or others. Use adequate respiratory protection. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.
Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness
Wash contact areas with soap and water.
Flush thoroughly with water.
Symptoms: irritation
First aid is normally not required.
Immediate Medical Attention
If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. Seek medical attention if discomfort occurs (ingestion).
Medical Treatment
Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
Straight streams of water
Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA). Use water spray to cool fire exposed surfaces and to protect personnel.
Firefighter Protection
Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with spilled material.
Dyke far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas.
Dyke far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas.
Recover by pumping or with suitable absorbent. Remove from the surface by skimming or with suitable absorbents.
Materials: suitable absorbents
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with used product. Prevent small spills and leakage to avoid slip hazard. Use proper bonding and/or earthing procedures. Consult local applicable standards for guidance.
The type of container used to store the material may affect static accumulation and dissipation. Do not store in open or unlabelled containers.
Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or earthing procedures. Consult local applicable standards for guidance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation.
Any specific glove information provided is based on published literature and glove manufacturer data. Glove suitability and breakthrough time will differ depending on the specific use conditions. Contact the glove manufacturer for specific advice on glove selection and breakthrough times for your use conditions. Inspect and replace worn or damaged gloves. The types of gloves to be considered for this material include: No protection is ordinarily required under normal conditions of use.
If contact is likely, safety glasses with side shields are recommended.
If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to be considered for this material include: No special requirements under ordinary conditions of use and with adequate ventilation. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.
Any specific clothing information provided is based on published literature or manufacturer data. The types of clothing to be considered for this material include: No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.
Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
See sub-sections below.
Hazardous polymerization will not occur.
Excessive heat. High energy sources of ignition.
Strong oxidisers
Material does not decompose at ambient temperatures.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MOBIL 1 FS X1 5W-50?
The signal word is no signal word.
What is the physical form of MOBIL 1 FS X1 5W-50?
MOBIL 1 FS X1 5W-50 is a liquid with brown color. It has characteristic odor.
What is MOBIL 1 FS X1 5W-50 used for?
Engine oil
What is the melting point of MOBIL 1 FS X1 5W-50?
The melting point is Not technically feasible and the boiling point is > 316°C (600°F) [test method unavailable].