NextSDS Logo
Safety Data Sheet EN

MOBIL 1 FS X1 5W-50

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MOBIL 1 FS X1 5W-50
Product Code
2015101010Z7, 486811-60

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Engine oil

Uses advised against

None unless specified elsewhere in this SDS.

Manufacturers & Suppliers

ExxonMobil Petroleum & Chemical BV logo

ExxonMobil Petroleum & Chemical BV

manufacturer

POLDERDIJKWEG, B-2030 Antwerpen, Belgium

+32 3 790 3111

http://www.msds.exxonmobil.com

ExxonMobil Petroleum & Chemical BV logo

ExxonMobil Petroleum & Chemical BV

manufacturer

POLDERDIJKWEG, B-2030 Antwerpen, Belgium

0800 028 2851

http://www.msds.exxonmobil.com

Emergency Contacts

Emergency Contact

(+44) 870 8200418

24h

National Poison Control Centre

111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
1-Decene, tetramer, mixed with 1-decene trimer, hydrogenated EC: 614-695-9 68649-12-7 5 - 10% Yes
2-PENTANOL, 4-METHYL-, HYDROGEN PHOSPHORODITHIOATE, ZINC SALT EC: 218-679-9 2215-35-2 0.1 - 1% Yes
C14-16-18 ALKYL PHENOL EC: 931-468-2 --- 0.1 - 1% Yes
DISTILLATES, HEAVY, C18-50 - BRANCHED, CYCLIC AND LINEAR EC: 482-220-0 848301-69-9 30 - 40% Yes
maleic anhydride EC: 203-571-6 108-31-6 0.1% Yes
PHOSPHORODITHIOIC ACID, MIXED 0,0 BIS (1,3-DIMETHYLBUTYL AND ISO- PR)ESTERS, ZINC SALTS EC: 283-392-8 84605-29-8 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove from further exposure. For those providing assistance, avoid exposure to yourself or others. Use adequate respiratory protection. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.

Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness

Skin contact

Wash contact areas with soap and water.

Eye contact

Flush thoroughly with water.

Symptoms: irritation

Ingestion

First aid is normally not required.

Immediate Medical Attention

If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. Seek medical attention if discomfort occurs (ingestion).

Medical Treatment

Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Unsuitable media

Straight streams of water

Instructions

Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA). Use water spray to cool fire exposed surfaces and to protect personnel.

Firefighter Protection

Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with spilled material.

Large spill

Dyke far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas.

Environmental

Dyke far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas.

Cleanup methods

Recover by pumping or with suitable absorbent. Remove from the surface by skimming or with suitable absorbents.

Materials: suitable absorbents

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with used product. Prevent small spills and leakage to avoid slip hazard. Use proper bonding and/or earthing procedures. Consult local applicable standards for guidance.

Storage

The type of container used to store the material may affect static accumulation and dissipation. Do not store in open or unlabelled containers.

Fire prevention

Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or earthing procedures. Consult local applicable standards for guidance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

Any specific glove information provided is based on published literature and glove manufacturer data. Glove suitability and breakthrough time will differ depending on the specific use conditions. Contact the glove manufacturer for specific advice on glove selection and breakthrough times for your use conditions. Inspect and replace worn or damaged gloves. The types of gloves to be considered for this material include: No protection is ordinarily required under normal conditions of use.

Eyes

If contact is likely, safety glasses with side shields are recommended.

Respiratory

If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to be considered for this material include: No special requirements under ordinary conditions of use and with adequate ventilation. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.

Skin/Body

Any specific clothing information provided is based on published literature or manufacturer data. The types of clothing to be considered for this material include: No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.

Environmental

Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Brown
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
No data available
Ph
Not technically feasible
Melting Point
Not technically feasible
Boiling Point
> 316°C (600°F) [test method unavailable]
Flash Point
239°C (462°F) [Typical] [ASTM D-92]
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
< 0.013 kPa (0.1 mm Hg) at 20 °C [test method unavailable]
Vapor Density
> 2 at 101 kPa [test method unavailable]
Relative Density
0.85 [ASTM D4052] (at 15 °C)
Bulk Density
---
Density
---
Flammability
Not technically feasible
Upper Explosive Limit
7.0 [test method unavailable]
Lower Explosive Limit
0.9 [test method unavailable]
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
> 3.5 [test method unavailable]
Solubility In Water
Negligible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
101.1 cSt (101.1 mm2/sec) at 40°C | 16.72 cSt (16.72 mm2/sec) at 100°C [ASTM D 445]
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

See sub-sections below.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Excessive heat. High energy sources of ignition.

Incompatible

Strong oxidisers

Decomposition

Material does not decompose at ambient temperatures.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MOBIL 1 FS X1 5W-50?

The signal word is no signal word.

What is the physical form of MOBIL 1 FS X1 5W-50?

MOBIL 1 FS X1 5W-50 is a liquid with brown color. It has characteristic odor.

What is MOBIL 1 FS X1 5W-50 used for?

Engine oil

What is the melting point of MOBIL 1 FS X1 5W-50?

The melting point is Not technically feasible and the boiling point is > 316°C (600°F) [test method unavailable].