Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TECHNOMELT PA 6300
- Product Form
- Special hotmelt
- Product Code
- 2324528
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Notes
Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If symptoms persist, seek medical advice.
Cool skin rapidly with cold water after contact with molten material. Cover affected areas with clean sheeting or gauze and seek immediate medical attention.
If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.
Do not induce vomiting. Seek medical advice.
Immediate Medical Attention
Seek immediate medical attention for skin contact.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Keep unnecessary personnel away.
Firefighter Protection
Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow material to contaminate ground water system.
Sweep up spilled material.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not place wet or damp solid into melt tank. Follow suggested application temperature. Always be careful around molten material. Avoid skin contact with molten resins. Do not wear contact lenses. Avoid dust formation.
For safe storage, store at or below 34 °C (93.2 °F) Keep cool in accordance with information on label and in Technical Data Sheets.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Work should be done in an adequately ventilated area (i.e., ventilation sufficient to maintain concentrations below one half of the PEL and other relevant standards). Local exhaust ventilation is recommended when general ventilation is not sufficient to control airborne contamination.
Insulated gloves are strongly recommended when working with molten adhesive.
Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists. Do not wear contact lenses.
No personal respiratory protective equipment normally required. Where the potential exists for exposure to decomposition products due to heating or elevated temperatures, wear NIOSH approved respiratory protection as appropriate. Observe OSHA regulations for respirator use (29 CFR 1910.134). Solid Resin: Dust safety masks are recommended when the potential for dust inhalation exists.
Long sleeved clothing are strongly recommended when working with molten adhesive.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
Not available.
Will not occur.
To avoid thermal decomposition, do not overheat. Avoid temperatures above 200°C (392°F).
Acids. Bases. Oxidizing agents.
Oxides of carbon. Thermal decomposition can lead to release of irritating gases and vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TECHNOMELT PA 6300?
The signal word is no signal word.
What is the physical form of TECHNOMELT PA 6300?
TECHNOMELT PA 6300 is a solid with amber color.
What is the solubility of TECHNOMELT PA 6300?
Insoluble Water
What are the hazard statements for TECHNOMELT PA 6300?
This substance has 3 hazard statements:
- MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.
- VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
- STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.
What is the melting point of TECHNOMELT PA 6300?
The melting point is 191 - 201 °C (375.8 - 393.8 °F) and the boiling point is > 280 °C (> 536°F).