NextSDS Logo
Safety Data Sheet EN

TECHNOMELT PA 673 N

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TECHNOMELT PA 673 N
Product Code
2907440

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Special hotmelt, based on polyamide

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.
VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Polyamide Based Hotmelt Adhesive

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.

Skin contact

Cool melted product on skin with plenty of water. Do not remove solidified product. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn. Cover affected areas with clean sheeting or gauze and seek immediate medical attention.

Symptoms: Molten adhesive may cause severe burns.

Eye contact

If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.

Ingestion

If symptoms develop and persist, get medical attention.

Symptoms: Ingestion of solid adhesive is not expected to be hazardous.

Immediate Medical Attention

Seek immediate medical attention for molten adhesive burns.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Specific hazards

In case of fire, keep containers cool with water spray.

Instructions

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not allow material to contaminate ground water system. No special environmental precautions required.

Cleanup methods

Sweep up spilled material.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not place wet or damp solid into melt tank. Follow suggested application temperature. Always be careful around molten material. Avoid skin contact with molten resins. Do not wear contact lenses. Avoid dust formation.

Storage

Keep the container tightly closed and in a cool, well-ventilated place.

Hygiene

Do not wear contact lenses.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ventilation hoods and fans required when working with organic solvents or in hot melt applications. Heat only in areas with appropriate exhaust ventilation.

Hands

Insulated gloves are strongly recommended when working with molten adhesive.

Eyes

Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists. Do not wear contact lenses.

Respiratory

Solid Resin: Dust safety masks are recommended when the potential for dust inhalation exists. Molten Resin: Use a NIOSH approved air-purifying respirator with an organic vapor cartridge.

Skin/Body

Long sleeved clothing are strongly recommended when working with molten adhesive.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solidification Point
---
Form
---
Dynamic Viscosity
---
Molecular Weight
---
Flammability
The product is not flammable.
Lower Explosive Limit
Not available.
Vapor Pressure
< 0.1 hPa (20 °C (68°F))
Solubility In Water
Insoluble
Relative Density
1
Metal Corrosion
---
Cloud Point
---
Auto Ignition Temperature
Not available.
Odor Threshold
Not available.
Properties Status
---
Ph
Not applicable, Product is non-soluble (in water).
Relative Evaporation Rate
---
Vapor Density
Not applicable, Product is a solid.
Freezing Point
---
Decomposition Temperature
> 300 °C
Odor
Odorless
Solubility
---
Upper Explosive Limit
Not available.
Boiling Point
Not available.
Explosive Limits
---
Colour Intensity
---
Softening Point
---
Bulk Density
---
Evaporation Rate
Not available.
Voc Content
0 %
Flash Point
Not applicable
Kinematic Viscosity
---
Density
---
Solubility In Fat
---
Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Melting Point
180 - 190 °C (356°F - 374°F)
Crystallisation Point
---
Appearance
---
Partition Coefficient
Not available.
Colour
Amber
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

Excessive heat.

Incompatible

Avoid heating above 400°F.

Decomposition

Carbon dioxide, carbon monoxide and irritating and/or toxic gases and particulate may be generated by thermal decomposition or combustion.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TECHNOMELT PA 673 N?

The signal word is no signal word.

What is the physical form of TECHNOMELT PA 673 N?

TECHNOMELT PA 673 N is a solid with amber color. It has odorless odor.

What is TECHNOMELT PA 673 N used for?

Special hotmelt, based on polyamide

What are the hazard statements for TECHNOMELT PA 673 N?

This substance has 3 hazard statements:

  • MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.
  • VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
  • STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.

What is the melting point of TECHNOMELT PA 673 N?

The melting point is 180 - 190 °C (356°F - 374°F) and the boiling point is Not available..