01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Technomelt PS 713A
Product Form
Hotmelt adhesive
Product Code
1217759

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.
VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Notes

Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If symptoms develop and persist, get medical attention.

Skin contact

Cool melted product on skin with plenty of water. Do not remove solidified product. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn. Cover affected areas with clean sheeting or gauze and seek immediate medical attention.

Symptoms: Molten adhesive may cause severe burns.

Eye contact

If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.

Ingestion

Ingestion of solid adhesive is not expected to be hazardous. If symptoms develop and persist, get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures appropriate to local circumstances and the surrounding environment. Dry chemical. Carbon dioxide.

Unsuitable media

Not available.

Instructions

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

Firefighter Protection

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

No special environmental precautions required. Do not allow material to contaminate ground water system.

Cleanup methods

Spilled material will solidify. Scrape up spilled material and place in a closed container for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Always be careful around molten material. Avoid skin contact with molten resins. Follow suggested application temperature. Do not wear contact lenses. At elevated temperatures, irritating fumes may be emitted. Wash hands before breaks and immediately after handling the product.

Storage

Store between 0.0 °C (32°F) and 38.0 °C (100.4 °F)

Hygiene

Wash hands before breaks and immediately after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Auto Ignition Temperature
Not applicable
Flash Point
>260.00 °C (>500°F) Cleveland open cup
Colour
Yellow
Appearance
---
Colour Intensity
---
Metal Corrosion
---
Decomposition Temperature
Not available.
Solidification Point
---
Odor Threshold
Not available.
Ph
Not available.
Solubility In Fat
---
Flammability
Not applicable
Voc Content
0 %
Relative Evaporation Rate
---
Form
---
Upper Explosive Limit
Not applicable
Softening Point
---
Melting Point
110 °C (230°F)
Kinematic Viscosity
Not available.
Partition Coefficient
Not available.
Explosive Limits
---
Vapor Density
---
Physical State
Solid
Molecular Weight
---
Evaporation Rate
Not applicable
Vapor Pressure
Negligible vapor pressure at ambient temperatures.
Dynamic Viscosity
Not available.
Freezing Point
---
Boiling Point
>260 °C (>500°F)
Cloud Point
---
Solubility In Water
---
Crystallisation Point
---
Lower Explosive Limit
Not applicable
Solubility
Insoluble Water
Physical State Data
solid
Odor
---
Properties Status
---
Relative Density
0.98
Bulk Density
---
State Under Standard Conditions
---
Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

To avoid thermal decomposition, do not overheat. Avoid temperatures above 200°C (392°F).

Incompatible

Oxidizing agents.

Decomposition

Thermal decomposition can lead to release of irritating gases and vapors. carbon monoxide carbon dioxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Technomelt PS 713A?

The signal word is no signal word.

What is the physical form of Technomelt PS 713A?

Technomelt PS 713A is a solid with yellow color.

What is the solubility of Technomelt PS 713A?

Insoluble Water

What are the hazard statements for Technomelt PS 713A?

This substance has 3 hazard statements:

  • MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.
  • VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
  • STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.

What is the melting point of Technomelt PS 713A?

The melting point is 110 °C (230°F) and the boiling point is >260 °C (>500°F).