Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BONDERITE M-PT R 300 POST TREATMENT known as POLYPREP RINSE 300
- Product Code
- 592998
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cleaner
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Alcohols, C6-10, ethoxylated propoxylated 60 - 80%
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Alcohols, C6-10, ethoxylated propoxylated | 68987-81-5 | 60 - 80% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, immediately remove the affected person to fresh air.
Immediately wash skin thoroughly with soap and water.
In case of contact with eyes, rinse immediately with plenty of water.
Seek medical advice. DO NOT induce vomiting unless directed to do so by medical personnel.
Immediate Medical Attention
If symptoms develop and persist, get medical attention.
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use media appropriate for surrounding material.
Not available.
May liberate large quantities of dense, foul-smelling smoke which may contain unidentified toxic gasses.
Wear full protective clothing. Wear self-contained breathing apparatus.
Firefighter Protection
Wear full protective clothing. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so. Wear appropriate protective equipment and clothing during clean-up. Do not allow product to enter sewer or waterways.
Absorb spill with inert material. Shovel material into appropriate container for disposal. Dispose of according to Federal, State and local governmental regulations.
Materials: inert material
Related Products
Similar products with comparable safety profiles
BONDERITE M-PT R 400 POST TREATMENT
---
BONDERITE M-PT R 400RA POST TREATMENT
---
BONDERITE M-PT E3C RR POST TREATMENT
---
BONDERITE M-PT R 205 POST TREATMENT
---
BONDERITE M-PT DX AID POST TREATMENT known as DX RINSE AID
---
BONDERITE M-AD 300 PRETREATMENT ADDITIVE
---
BONDERITE M-PT 99 CWN POST TREATMENT
---
BONDERITE M-PT 60A POST TREATMENT
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid breathing vapors or mists of this product. Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Do not take internally. For industrial use only.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials.
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide local and general exhaust ventilation to effectively remove and prevent buildup of any vapors or mists generated from the handling of this product.
Chemical resistant, impermeable gloves. Gloves should be tested to determine suitability for prolonged contact.
Wear safety glasses; chemical goggles (if splashing is possible).
If ventilation is not sufficient to effectively prevent buildup of aerosols, mists or vapors, appropriate NIOSH/MSHA respiratory protection must be provided.
Use of impervious apron and boots are recommended.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
This product may react with strong reducing agents.
None under normal processing.
Store away from incompatible materials.
Strong oxidizing agents.
Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Oxides of nitrogen.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for BONDERITE M-PT R 300 POST TREATMENT known as POLYPREP RINSE 300?
The signal word is warning.
What is the physical form of BONDERITE M-PT R 300 POST TREATMENT known as POLYPREP RINSE 300?
BONDERITE M-PT R 300 POST TREATMENT known as POLYPREP RINSE 300 is a liquid with colourless / colorless color. It has mild odor.
What is the solubility of BONDERITE M-PT R 300 POST TREATMENT known as POLYPREP RINSE 300?
fully soluble Water
What is BONDERITE M-PT R 300 POST TREATMENT known as POLYPREP RINSE 300 used for?
Cleaner
What are the hazard statements for BONDERITE M-PT R 300 POST TREATMENT known as POLYPREP RINSE 300?
This substance has 1 hazard statement:
- H319: CAUSES SERIOUS EYE IRRITATION.
What is the melting point of BONDERITE M-PT R 300 POST TREATMENT known as POLYPREP RINSE 300?
The melting point is Not available. and the boiling point is 212 °F (100°C) None.