Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TECHNOMELT 8011 18KG
- Product Code
- 3148344
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hotmelt adhesive
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Paraffin waxes and Hydrocarbon waxes | 8002-74-2 | 10 - 30% | No |
| Copolymer | --- | 5 - 10% | No |
| rosin | 8050-09-7 | 1 - 5% | No |
IDH number: 3148344 Product name: TECHNOMELT 8011 18KG
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
If not breathing, give artificial respiration. If breathing is difficult, oxygen should be administered by qualified personnel. Move to fresh air. If symptoms persist, seek medical advice.
Cool skin rapidly with cold water after contact with molten material. Cover affected areas with clean sheeting or gauze and seek immediate medical attention. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn.
Symptoms: Molten adhesive may cause severe burns.
If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.
If symptoms develop and persist, get medical attention.
Symptoms: Ingestion of solid adhesive is not expected to be hazardous.
Immediate Medical Attention
Seek immediate medical attention for skin contact. Seek medical attention for eye contact, inhalation, or if ingestion symptoms persist.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures appropriate to local circumstances and the surrounding environment. Dry chemical. Carbon dioxide.
Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.
Firefighter Protection
Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
isolate the hazard area and deny entry to unnecessary and unprotected personnel.
No special environmental precautions required. Do not allow material to contaminate ground water system.
Spilled material will solidify. Scrape up spilled material and place in a closed container for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Always be careful around molten material. Avoid skin contact with molten resins. Follow suggested application temperature. Do not wear contact lenses. At elevated temperatures, irritating fumes may be emitted. Wash hands before breaks and immediately after handling the product.
Store between 0.0 °C (32°F) and 38.0 °C (100.4 °F)
Wash hands before breaks and immediately after handling the product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
Not available.
Will not occur.
To avoid thermal decomposition, do not overheat. Avoid temperatures above 200°C (392°F).
Oxidizing agents.
Thermal decomposition can lead to release of irritating gases and vapors. carbon monoxide carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TECHNOMELT 8011 18KG?
The signal word is danger.
What is the physical form of TECHNOMELT 8011 18KG?
TECHNOMELT 8011 18KG is a solid with yellow color. It has odorless odor.
What is TECHNOMELT 8011 18KG used for?
Hotmelt adhesive
What are the hazard statements for TECHNOMELT 8011 18KG?
This substance has 2 hazard statements:
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
What is the melting point of TECHNOMELT 8011 18KG?