NextSDS Logo
Safety Data Sheet EN

TECHNOMELT SUPRA COOL 130A 15KG

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TECHNOMELT SUPRA COOL 130A 15KG
Product Form
Hotmelt adhesive
Product Code
1864086

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

GHS Pictograms

Hazard Statements

MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.
VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Notes

Exact percentages may vary or are trade secret.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If symptoms develop and persist, get medical attention.

Skin contact

Cool melted product on skin with plenty of water. Do not remove solidified product. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn. Cover affected areas with clean sheeting or gauze and seek immediate medical attention.

Symptoms: Molten adhesive may cause severe burns.

Eye contact

If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.

Ingestion

Ingestion of solid adhesive is not expected to be hazardous. If symptoms develop and persist, get medical attention.

Immediate Medical Attention

Seek immediate medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures appropriate to local circumstances and the surrounding environment. Dry chemical. Carbon dioxide.

Instructions

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

Firefighter Protection

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

No special environmental precautions required. Do not allow material to contaminate ground water system.

Cleanup methods

Spilled material will solidify. Scrape up spilled material and place in a closed container for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Always be careful around molten material. Avoid skin contact with molten resins. Follow suggested application temperature. Do not wear contact lenses. At elevated temperatures, irritating fumes may be emitted. Wash hands before breaks and immediately after handling the product.

Storage

Store between 0.0 °C (32°F) and 38.0 °C (100.4 °F)

Hygiene

Wash hands before breaks and immediately after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Work should be done in an adequately ventilated area (i.e., ventilation sufficient to maintain concentrations below one half of the PEL and other relevant standards). Local exhaust ventilation is recommended when general ventilation is not sufficient to control airborne contamination.

Eyes

Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists. Do not wear contact lenses.

Respiratory

No personal respiratory protective equipment normally required. Where the potential exists for exposure to decomposition products due to heating or elevated temperatures, wear NIOSH approved respiratory protection as appropriate. Observe OSHA regulations for respirator use (29 CFR 1910.134).

Skin/Body

long sleeved clothing are strongly recommended when working with molten adhesive.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
Not available.
Melting Point
110 °C (230°F)
Auto Ignition Temperature
Not applicable
Relative Density
0.9800
Kinematic Viscosity
---
Softening Point
---
Flammability
Not applicable
Density
---
Boiling Point
Not available.
Odor
Negligible
Colour Intensity
---
Lower Explosive Limit
Not applicable
Appearance
---
Physical State
solid
Dynamic Viscosity
---
Colour
white
Bulk Density
---
Crystallisation Point
---
Odor Threshold
Not available.
Upper Explosive Limit
Not applicable
Vapor Pressure
Not available.
Physical State Data
solid
Properties Status
---
Solubility In Water
Insoluble
Voc Content
0 %
Metal Corrosion
---
Solubility In Fat
---
Solidification Point
---
Cloud Point
---
Freezing Point
---
Decomposition Temperature
Not available.
Solubility
---
Evaporation Rate
Not applicable
Form
---
Ph
Not available.
Explosive Limits
---
Flash Point
> 210 °C (> 410°F)
Molecular Weight
---
Vapor Density
Not available.
State Under Standard Conditions
---
Relative Evaporation Rate
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

To avoid thermal decomposition, do not overheat. Avoid temperatures above 200°C (392°F).

Incompatible

Oxidizing agents.

Decomposition

Thermal decomposition can lead to release of irritating gases and vapors. carbon monoxide carbon dioxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TECHNOMELT SUPRA COOL 130A 15KG?

The signal word is no signal word.

What is the physical form of TECHNOMELT SUPRA COOL 130A 15KG?

TECHNOMELT SUPRA COOL 130A 15KG is a solid with white color. It has negligible odor.

What are the hazard statements for TECHNOMELT SUPRA COOL 130A 15KG?

This substance has 3 hazard statements:

  • MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.
  • VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
  • STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.

What is the melting point of TECHNOMELT SUPRA COOL 130A 15KG?

The melting point is 110 °C (230°F) and the boiling point is Not available..