Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
BONDERITE S-FN EV 600CC ACHESON
Product Code
2793123

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Carbon black 1333-86-4 1 - 5% Yes
Graphite 7782-42-5 10 - 30% Yes

IDH number: 2793123 Product name: BONDERITE S-FN EV 600CC ACHESON

Notes

Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If symptoms are experienced, remove source of contamination or move victim to fresh air.

Skin contact

Immediately wash skin thoroughly with soap and water. If symptoms develop and persist, get medical attention.

Eye contact

Flush eye(s) immediately with plenty of water. If eye irritation persists, consult a specialist.

Ingestion

If ingestion of a large amount does occur, seek medical attention.

Immediate Medical Attention

If ingestion of a large amount does occur, seek medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Unsuitable media

Not available.

Specific hazards

May liberate large quantities of dense, foul-smelling smoke which may contain unidentified toxic gasses.

Instructions

Wear full protective clothing. Wear self-contained breathing apparatus.

Firefighter Protection

Wear full protective clothing. Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Absorb spill with inert material. Shovel material into appropriate container for disposal.

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Use only with adequate ventilation. Do not take internally. For industrial use only.

Storage

For safe storage, store between 5 °C (41°F) and 35 °C (95°F) Protect from freezing, freezing temperature is <=32F (<=0C). Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use. Protect from direct sunlight.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep in a cool, well ventilated area away from heat, sparks and open flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Kinematic Viscosity
> 20.5 mm2/s
Cloud Point
---
Auto Ignition Temperature
Not applicable
Solubility In Fat
---
Relative Density
1.10 - 1.13
Vapor Pressure
23.4 hPa (20 °C (68°F)) no method / method unknown Values referring to water
Solubility In Water
---
Relative Evaporation Rate
---
Ph
8 - 9
Solidification Point
---
Crystallisation Point
---
Flammability
The product is not flammable.
Decomposition Temperature
Not available.
Voc Content
< 1.5 g/l (calculated)
Vapor Density
---
Boiling Point
100 °C (212°F)
Physical State Data
liquid
Dynamic Viscosity
50.0 - 200.0 cp
Odor
Ammoniacal
Explosive Limits
---
Colour Intensity
---
Softening Point
---
Odor Threshold
Not available.
Upper Explosive Limit
Not available.
Partition Coefficient
Not determined
Metal Corrosion
---
Lower Explosive Limit
Not available.
Colour
Black
Evaporation Rate
1 (Butyl acetate = 1)
State Under Standard Conditions
---
Form
---
Appearance
---
Properties Status
---
Flash Point
> 100 °C (> 212°F)
Density
---
Molecular Weight
---
Freezing Point
---
Bulk Density
---
Melting Point
Not available.
Solubility
Miscible Water
Physical State
Liquid
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at normal conditions.

Reactivity

Not available.

Hazardous reactions

None under normal processing.

Avoid

Elevated temperatures.

Incompatible

This product reacts with acids.

Decomposition

Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for BONDERITE S-FN EV 600CC ACHESON?

The signal word is no signal word.

What is the physical form of BONDERITE S-FN EV 600CC ACHESON?

BONDERITE S-FN EV 600CC ACHESON is a liquid with black color. It has ammoniacal odor.

What is the solubility of BONDERITE S-FN EV 600CC ACHESON?

Miscible Water

What is the melting point of BONDERITE S-FN EV 600CC ACHESON?

The melting point is Not available. and the boiling point is 100 °C (212°F).