NextSDS Logo
Safety Data Sheet EN

TECHNOMELT DM 519A F

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TECHNOMELT DM 519A F
Product Form
Hotmelt adhesive
Product Code
2969157

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS. VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION. STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
White mineral oil (petroleum) 8042-47-5 10 - 30% Yes

IDH number: 2969157 Product name: TECHNOMELT DM 519A F

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If not breathing, give artificial respiration. If breathing is difficult, oxygen should be administered by qualified personnel. Move to fresh air. If symptoms persist, seek medical advice.

Skin contact

Cool skin rapidly with cold water after contact with molten material. Cover affected areas with clean sheeting or gauze and seek immediate medical attention. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn.

Symptoms: Molten adhesive may cause severe burns.

Eye contact

If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.

Ingestion

If symptoms develop and persist, get medical attention.

Immediate Medical Attention

Seek immediate medical attention for skin contact. Seek medical attention for eye contact. If symptoms persist, seek medical advice for inhalation or ingestion.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures appropriate to local circumstances and the surrounding environment. Dry chemical. Carbon dioxide.

Unsuitable media

Not available.

Instructions

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

Firefighter Protection

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

No special environmental precautions required. Do not allow material to contaminate ground water system.

Cleanup methods

Spilled material will solidify. Scrape up spilled material and place in a closed container for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Always be careful around molten material. Avoid skin contact with molten resins. Follow suggested application temperature. Do not wear contact lenses. At elevated temperatures, irritating fumes may be emitted. Wash hands before breaks and immediately after handling the product.

Storage

store between 0.0 °C (32°F) and 38.0 °C (100.4 °F)

Hygiene

Wash hands before breaks and immediately after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Vapor Density
---
Ph
Not applicable, Product is non-soluble (in water).
Crystallisation Point
---
Properties Status
---
Solubility In Fat
---
Metal Corrosion
---
Solubility In Water
---
Voc Content
0 %
Density
---
Cloud Point
---
Softening Point
---
Dynamic Viscosity
1,800 - 2,900 mPa.s
Odor
Mild, Rubber-like
Colour
Light yellow
Bulk Density
---
Flash Point
Not applicable
Freezing Point
---
Upper Explosive Limit
Not available.
Solubility
Insoluble Water
Explosive Limits
---
Relative Evaporation Rate
---
Melting Point
71 °C (159.8 °F)
Kinematic Viscosity
Not available.
Vapor Pressure
< 0.1 hPa (20 °C (68°F))
Appearance
---
Odor Threshold
Not available.
Physical State Data
solid
Partition Coefficient
Not available.
Solidification Point
---
Flammability
The product is not flammable.
Lower Explosive Limit
Not available.
Form
---
Evaporation Rate
Not available.
Auto Ignition Temperature
Not available.
Colour Intensity
---
Boiling Point
Not applicable, Polymeric solid, thermally degrades above 250 °C.
Molecular Weight
---
Decomposition Temperature
Not available.
State Under Standard Conditions
---
Relative Density
Not available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

To avoid thermal decomposition, do not overheat. Avoid temperatures above 200°C (392°F).

Incompatible

Oxidizing agents.

Decomposition

Thermal decomposition can lead to release of irritating gases and vapors. carbon monoxide carbon dioxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TECHNOMELT DM 519A F?

The signal word is no signal word.

What is the physical form of TECHNOMELT DM 519A F?

TECHNOMELT DM 519A F is a solid with light yellow color. It has mild, rubber-like odor.

What is the solubility of TECHNOMELT DM 519A F?

Insoluble Water

What are the hazard statements for TECHNOMELT DM 519A F?

This substance has 1 hazard statement:

  • MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS. VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION. STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.

What is the melting point of TECHNOMELT DM 519A F?

The melting point is 71 °C (159.8 °F) and the boiling point is Not applicable, Polymeric solid, thermally degrades above 250 °C..